Roiscok iDo218 Manual de usuario

iDo218
Wireless Alarm System

Contents
……………………………………………
……………………
………………………………………………
………………………………… …
…………… …
………………………………………………
………………………… ………… ……
……………………………
………………………………………………
………………………………………
…………………… ……… … …
……… ……
………………………… …… ……………
…………………………………………………
……………………………………………………
………………………………………………
…………………… ……
PACKING LIST 1
2
2
3
4
6
9
9
Arm System 20
CHAPTER 1 SUMMARY
Keys and LEDs
Main Function of iDo218
Components and Technology Data of iDo218
Technical Data 6
Professional Terms
CHAPTER 2 KEY PROGRAMMING
Keys Functions
Programming iDo218 11
Form 1.Summary of Menu 12
CHAPTER 3 SYSTEM OPERATIONS AND USAGE 19
Restore Default 19
Stay Arm 21
System Disarm 21
Arm/Disarm by Remote Controller 22
……………………
1-1
i Wireless Alarm SystemDo218

………………………………………
………………………
…………………………………………
…………………………………………………
……………… …… …………
……………………………………………
…………………………………………………
……………………………………………
……………………………………………………
……………………………………
……………
…………………………………
…………………………………………
……………………
………………………………………………
…………………………………………
…………………………………………………………
Arm/Disarm by Phone 23
Matching Remote Controller iDo104 24
Matching Detector 25
Zone Types 27
User Code and Rights Grade 27
Emergency Keys 29
Door Chime 29
Entry/Exit Delay 29
Events Log
Wrong Code Operation
Setting for against electromagnetic interference
Installation and Connection
CHAPTER 4 APPENDIX 35
iDo218UD and Remote PC Management 35
iDo218 Events
Mounting Detectors
FAQ 46
30
30
30
32
43
44
1-2
i Wireless Alarm SystemDo218

1
i Wireless Alarm SystemDo218

iDo218 wireless net-workable control panel has perfect function, is
widely used for home and commercial alarm systems. It can match
with all kinds of wireless detectors of ROISCOK and iDo. It is easy
and delightful to installers for its menu operation. The radio frequency
is 433.92MHz.
CHAPTER 1 SUMMARY
b. Signal LED
e. Move left key
h. Arm LED
k. Arm key
c. Stay arm LED
f. In and out menu key
i. Trouble LED
l. Move right key
a. Power LED
d. Stay arm key
g. Confirm key
j. Record LED
m. Buzzer and record window
Keys and LEDs
Fig 1.
2
a
b
c
d
e
f
g
h
i
j
k
l
m
i Wireless Alarm SystemDo218

Main Function of iDo218
●
●
●
●
●
●
●
●
●
●
●
62 wireless programmable zones. All the zones are defaulted as
alarm zones, and can be changed through programming.
All the zones can be divided into up to 5 partitions, partition 0-4.
Partition 1-4 can be individually armed / disarmed, also set the
daytime for automatically armed / disarmed; partition 0 is special, as
long as arm any one of the partition, partition 0 will be automatically
armed. All zones are defaulted as partition 0.
Build-in a dialer, can alarm to Central Monitor Station and / or the
users' phone numbers through PSTN/DTMF, it is compatible with
Contact ID communication format.
Alarm report can be sent to 4 follow-me phone numbers, or / and 4
central monitor station numbers at the same time. It can report 4
different Central Monitor Stations.
With grade code and duress code: Main Code, Manage Code, User
Code, One-off code and only disarm code.
Up to 127 events log which can be checked on LCD. All the events
can be chosen and sent to central monitor station, but cannot be
deleted.
With build-in recorder can record 20 seconds voice. The record
voice will play 3 times through follow-me numbers when alarm.
Alarm call has priority function.
Build-in siren driver, can drive build-in siren and 15W outside siren.
Matched for up to 10 remote controllers. Arm and Disarm iDo218 by
remote controller;
Arm and disarm iDo218 through line/mobile phone.
,
3
i Wireless Alarm SystemDo218

●
The iDo218 is powered by an adapter of 12V/2A DC, with 16 keys, a
large 4 lines LCD, 6 LED, a USB port, a phone port and a network port.
On the main board, there are a build-in siren and MIC, a connector for
outside siren and phone line and UO. Figure 1 and Figure 2
About iDo218
()
Components and Technology Data of iDo218
●
●
mentWith remote manage function, iDo218 can be remote managed
and programmed by computer.
With a Ni-MH rechargeable battery pack, the system can work more
around 36 hours after lose AC supply.
4
●Zones and Partitions
iDo218 has 62 zones, can be matched with 62 different types of
wireless detectors. All zones can be divided into four separate
partitions and a special partition. Each individual partition can be
individually armed and disarmed. Apply anti-theft protection system
composed of multi-user.
Fig 2.
a USB b Power c el Set
d Tel Line e Network
.. .T
..
abcd e
i Wireless Alarm SystemDo218

5
●
●
●
●
Every partition can set different time for auto arm/disarm.
According to the built-in clock, the system can be set up auto arm time
and auto disarm time so that one or more partitions automatically arm
and disarm in the same time every day. Each partition can be set an
independent time.
Zones Supervision
Code and Grading
Recorder, Communicator and Follow-me Number
Auto Arm/Disarm
The detector will send a report to the iDo218 to confirm itself every
2.5 hours. The iDo218 will alarm to the central monitor station if no
report received in 16 hours.
iDo218 can be set up 10 grading codes. Including a master code, an
administrator code, and six user's codes, an only arm code and one-off
disarm code. All the code can automatically generate a duress code.
Master code has the top grade. The administrator code can be used to
determine the permissions to each user.
IDo218 has build-in recorder with 20 seconds.
IDo218 has build-in digital communicator with Contact ID
communication format. It can be set up to 4 central monitor station
numbers. When alarm, iDo218 will report alarm information to the
central monitor station through telephone (PSTN/DTFM). It also can
be set up to 4 follow-me numbers. It can send pre-recorded voice to
each follow-me number when alarm.
iDo218 can be programmed to one or several partitions which can auto
arm/disarm at the same time everyday according to the build-in clock.
i Wireless Alarm SystemDo218

6
Input power
Standby battery
External siren driver
Maximum consumption
Minimum consumption
Dimensions
DC12V 2A
196×167×39 mm
40mA, under battery supply
Basic 45mA, LCD backlight 60mA
and internal siren 5mA
DC12V15W
9.6VDC1500mAH
Ni-MH rechargeable battery pack.
Technical Data
●
●
Arm/Disarm
Events Log
User can arm/disarm iDo218 by the following three ways: keys,
remote controller, line phone or/and mobile phone.
iDo218 can save up to 127 events, including arm, disarm, alarm, etc.
Professional Terms
●Zone Types
There are 9 zone types as: alarm, transfer, close, Stay, 24 hours, gas,
medical, panic and fire. The transfer zone is used only for the radio
repeater.
Alarm zone could be set as entry/exit delay zone and instant zone.
When trigger delay zone, the system will alarm after the delay time
When trigger instant zone, the system will alarm immediately.
;
i Wireless Alarm SystemDo218

7
24 hours' zones can not be disarmed, such as 24 hour, gas, medical,
emergency and fire.
Stay Zone means when press [STAY] to arm the system, they are
bypassed and cannot be armed.
Close zone cannot be armed anytime.
Each wireless detectors / wireless repeater has a fixed and unique ID
code. Before use, you must first match this ID to the control panel.
Otherwise, the signal from detector or repeater would not be received
by the control panel. This process is called Matching.
All the happened by system called event, including disarm, arm,
alarm, iDo218 power low, detector power low, detector
communication failure, clock failure, siren failure and so on.
ARM means start the warning status for part or all of the zones,
DISARM means close the warning for part or all the zones.
During arming, iDo218 will alarm when any detector is triggered.
During disarming, iDo218 will not alarm when any detector is
triggered.
User can set 4 groups of users' telephone (line phone or mobile phone)
numbers. iDo218 will send alarm voice to some phone number(s)
when alarm. The numbers are called follow-me number.
Detector / Repeater Matching
Event
Arm/Disarm
Follow-me number
status
●
●
●
●
i Wireless Alarm SystemDo218
Tabla de contenidos
Manuales populares de Sistema de seguridad de otras marcas

EDM
EDM Solution 6+6 Wireless-AE Manual de usuario

Highway Safety Group
Highway Safety Group EA401 Manual de usuario

Siren
Siren LED GSM Manual de usuario

Detection Systems
Detection Systems 7090i Instrucciones de montaje

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manual de usuario

Siemens
Siemens FDM273 Manual de usuario