Rohde & Schwarz EB510 Manual de usuario

R&S® EB510
HF Monitoring Receiver
Getting Started
Getting Started
(Xé×V2)
4091.7338.02 ─ 01
Radiomonitoring & Radiolocation

This manual describes the following models and options:
●R&S®EB510 HF Monitoring Receiver 4091.7009.02 (without front control panel)
●R&S®EB510 HF Monitoring Receiver 4091.7009.03 (with front control panel)
The firmware of the R&S EB510 makes use of several valuable open source software packages. Please
refer to the "Open Source Acknowledgement" document (4072.8561.02) for a summary of the packages and
the verbatim license texts.
Rohde & Schwarz would like to thank the open source community for their valuable contribution to embedded
computing.
© 2011 Rohde & Schwarz GmbH & Co. KG
Muehldorfstr. 15, 81671 Munich, Germany
Phone: +49 89 41 29 - 0
Fax: +49 89 41 29 12 164
E-mail: [email protected]
Internet: http://www.rohde-schwarz.com
Printed in Germany – Subject to change – Data without tolerance limits is not binding.
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG.
Trade names are trademarks of the owners.
The following abbreviations are used throughout this manual: R&S®EB510 is abbreviated as R&S EB510.

Contents
R&S® EB510
3Getting Started 4091.7338.02 ─ 01
Contents
1Preparation for Use...............................................................5
1.1 Specific Safety Instructions.................................................................5
1.2 Setup......................................................................................................6
1.2.1 Bench Operation.....................................................................................6
1.2.2 Rack Mounting........................................................................................8
1.2.3 In-vehicle Mounting.................................................................................8
1.2.4 EMI Protective Measures........................................................................8
1.2.5 Connecting the R&S EB510 to the Power Supply..................................8
1.2.6 Power On and Off.................................................................................10
1.2.7 STANDBY and READY.........................................................................10
1.2.8 Connecting External Accessories.........................................................11
2Operation..............................................................................12
2.1 Front-Panel Tour.................................................................................12
2.1.1 EB510 with front control panel..............................................................12
2.1.2 EB510 without front control panel.........................................................14
2.2 Rear-Panel Tour..................................................................................16
2.3 Graphical User Interface (GUI)...........................................................18
2.3.1 GUI Layout............................................................................................18
2.3.2 Turning on the R&S EB510 for the First Time......................................20
2.3.3 Online Help...........................................................................................32
3Maintenance.........................................................................37
3.1 Cleaning...............................................................................................37
3.2 Storing and Packing...........................................................................37
3.3 Test Points...........................................................................................37

Contents
R&S® EB510
4Getting Started 4091.7338.02 ─ 01
4Software and Firmware Update..........................................39
4.1 Retrieve Firmware and GUI Versions................................................39
4.2 Receiver Firmware and GUI Update for EB510 with front control
panel.....................................................................................................40
4.2.1 Preparations..........................................................................................41
4.2.2 Update Procedure.................................................................................43
4.3 Receiver Firmware Update for EB510 without front control panel
..............................................................................................................48
4.3.1 Preparations..........................................................................................49
4.3.2 Firmware Update Using Update32 Tool................................................50
4.4 GUI Installation for Remote Access..................................................54
4.4.1 Preparations..........................................................................................54
4.4.2 Installation Procedure...........................................................................55
4.5 Changing the IP Address...................................................................59
4.5.1 Using Update32 Tool............................................................................59
4.5.2 Using GUI (EB510 with front control panel or Remote Access GUI)
..............................................................................................................61

Preparation for Use
R&S® EB510
5Getting Started 4091.7338.02 ─ 01
1 Preparation for Use
This section describes the basic steps to be taken when setting up the R&S EB510
for the first time.
1.1 Specific Safety Instructions
General safety instructions
Please follow the basic safety instructions included in this documentation as
well as the instructions for setup and connection to prevent personal injury or
damage to the R&S EB510. This is of particular importance when you use the
R&S EB510 for the first time.
The following safety instructions apply in particular:
●IEC 364
●VDE 0100
●DIN 57100
These safety regulations deal with the following aspects:
●Prevention of accidents
●Protection against overvoltage
●Insulation of equipment
●Grounding
●Characteristics and laying of lines and cables
●Provisions for operational facilities and rooms and systems of a special nature
Specific Safety Instructions

Preparation for Use
R&S® EB510
6Getting Started 4091.7338.02 ─ 01
Setup
Before turning on the R&S EB510, please make sure that the following con-
ditions are fulfilled:
●Covers are in place and all fasteners are tightened.
●Fan openings are unobstructed.
●Signal levels at the input connectors are all within the specified ranges.
●Signal outputs are correctly connected and not overloaded.
●The R&S EB510 is dry and shows no condensation.
Non-observance may cause damage to the R&S EB510 or other devices in
the setup.
The R&S EB510 is supplied completely assembled except for the handles and
mounting brackets, which must be attached by the user.
1.2 Setup
1.2.1 Bench Operation
Equipment cooling
Do not expose the R&S EB510 to humidity. Leave at least 50 mm of empty
space along both side panels in order to ensure proper equipment cooling.
There are no special requirements for desktop use. To facilitate access to the front
panel elements, you should raise the front of the R&S EB510 by folding out its
standing feet.
Setup

Preparation for Use
R&S® EB510
7Getting Started 4091.7338.02 ─ 01
Risk of injury
The feet may fold in if they are not folded out completely or if the R&S EB510
is shifted. The feet may break if they are overloaded. Fold the feet completely
in or completely out to ensure stability of the R&S EB510 and personal safety.
To avoid injuries, never shift the R&S EB510 when its feet are folded out. The
overall load (the R&S EB510's own weight plus that of any devices stacked
on top of it) on the folded-out feet must not exceed 500 N. Place the
R&S EB510 on a stable surface. Secure any devices stacked on top of it
against slipping (e.g. by locking their feet on the top front frame). When the
R&S EB510 is standing on its folded-out feet, do not work under it and do not
put anything under it as this would pose a risk of personal injury or material
damage.
The R&S EB510 can be used in any of the positions shown here.
Setup

Preparation for Use
R&S® EB510
8Getting Started 4091.7338.02 ─ 01
1.2.2 Rack Mounting
Ambient temperature
The R&S EB510 should be used in an area where the ambient temperature
does not exceed –10 °C to +55 °C (EB510 without front control panel) or 0 °C
to 55 °C (EB510 with front control panel), respectively. The R&S EB510 is
fan-cooled and must be installed with sufficient space along the sides to
ensure a free flow of air. Make sure that there is sufficient space for hot air to
escape from the R&S EB510. To ensure sufficient cooling do not attach tele-
scopic rails to the sides of the unit.
1.2.3 In-vehicle Mounting
For use in vehicles, the R&S EB510 can be powered directly from the vehicle's
battery via the DC input.
1.2.4 EMI Protective Measures
In order to avoid electromagnetic interference (EMI), the R&S EB510 may only be
operated when it is closed and all shielding covers are in place. Use only appropriate
shielded signal and control cables with proper termination.
1.2.5 Connecting the R&S EB510 to the Power Supply
Connect the R&S EB510 observing the following sections and instructions for use.
The R&S EB510 is suitable only for DC operation.
1.2.5.1 Connecting to the Power Adapter
The R&S EB510 is connected to the AC supply 100 V to 240 V via an external AC/
DC power adapter and to the socket X1 (10 VDC to 32 VDC) on the rear panel.
Recommended connector: Neutrik® Speakon® NL4FX (see the figure below).
Setup

Preparation for Use
R&S® EB510
9Getting Started 4091.7338.02 ─ 01
Installing the connector:
1. Insert the Speakon® NL4FX connector into socket X1 on the rear panel.
2. Turn the connector clockwise until it is locked in place and secured by the safety
latch.
Removing the connector:
1. Press and chuck back the safety latch of the Speakon® NL4FX connector.
2. Turn the connector counterclockwise and withdraw it.
Fig. 1-1: Speakon® NL4FX
1.2.5.2 Connecting to the DC Source
The R&S EB510 is connected to an external 10 VDC to 32 VDC source (e.g. battery)
via connector X1 on the rear panel. Recommended connector: Neutrik® Speakon®
NL4FX, see chapter 1.2.5.1, "Connecting to the Power Adapter", on page 8.
DC supply voltage
Make sure that the available supply voltage is between 10 V and 32 V.
Observe correct voltage polarity when connecting. Incorrect polarity may blow
the fuse on the DC converter inside the R&S EB510 or damage the
R&S EB510.
Setup

Preparation for Use
R&S® EB510
10Getting Started 4091.7338.02 ─ 01
1.2.6 Power On and Off
The DC power connection X1 is located at the top left corner of the
R&S EB510 rear panel. With the DC power connected, the
R&S EB510 is in STANDBY or READY state, depending on the state
of the STANDBY toggle switch at the front panel of the R&S EB510
when it was last switched off. The standby power is below 0.8 W.
1.2.7 STANDBY and READY
The STANDBY key is located at the bottom left corner of the front
panel. With the DC power connected, press the STANDBY key
briefly to switch the R&S EB510 from the STANDBY to the READY
state and vice versa. In STANDBY state, the amber LED on the right
will turn on and only the power switch circuit is being powered. In this state, it is safe
to remove the DC power and disconnect the R&S EB510 from the AC/DC power
adapter. In READY state, the green LED on the left is on. The R&S EB510 is ready
for operation. All modules are being powered and the
R&S EB510initiates its startup procedure.
EB510 without front control panel
In the case of EB510 without front control panel, the green Power LED dou-
bles as a 'Fail' status LED. In conditions of failure, the LED will turn red instead
of green, as shown in the figures below.
EB510 without front control panel Ready EB510 without front control panel in Failure
mode. Refer to the Troubleshooting section in
the Operating Manual for possible actions to
take.
Setup
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Receptor de Rohde & Schwarz

Rohde & Schwarz
Rohde & Schwarz EK 895 Manual de usuario

Rohde & Schwarz
Rohde & Schwarz ESRP EMI Manual de usuario

Rohde & Schwarz
Rohde & Schwarz EB200 Manual de usuario

Rohde & Schwarz
Rohde & Schwarz 890 Series Manual de usuario

Rohde & Schwarz
Rohde & Schwarz S4200 Manual de usuario

Rohde & Schwarz
Rohde & Schwarz R&S ESW Manual de usuario

Rohde & Schwarz
Rohde & Schwarz ESL3 Manual de usuario

Rohde & Schwarz
Rohde & Schwarz EMI Test ReceiverESCI Manual de usuario

Rohde & Schwarz
Rohde & Schwarz R&S EPL1000 Manual de usuario

Rohde & Schwarz
Rohde & Schwarz PR100 Manual de usuario