Ringmaster DNA934P Manual de usuario

DNA934P
Telephone Dialer Recorder
Ring Communications Inc.
Ring-Master


DNA934P Telephone Dialer with Recorder
Table of Contents
INTROD CTION:........................................................................................................................5
OPERATION:..............................................................................................................................5
INSTALLTION:............................................................................................................................7
J1 Connector:............................................................................................................................7
J3 Connector:............................................................................................................................8
Front Panel Switches and Indicators:......................................................................................8
Resetting Battery RAM:.............................................................................................................9
CONFIG RATION:...................................................................................................................10
Type fonts:...............................................................................................................................10
Prompt:....................................................................................................................................10
Error Handling:........................................................................................................................10
HELP COMMANDS:...............................................................................................................11
Telephone Numbers:...............................................................................................................11
LINE S PERVISION:................................................................................................................13
RECORDED MESSAGES:.......................................................................................................14
RM5000EX/CB901EX CONFIG RATION:..............................................................................15
CB901CA CONFIG RATION:..................................................................................................16


April 2017 Telephone Dialer with Recorder DNA934P
INTROD CTION
The DNA934P is an interface used for connecting the Intercom Central Exchange to a
telephone line connected to a PABX or the Central Office. One FXO Port is provided.
Recorder messages, phone numbers, number of rings and number of times to play the Caller ID
message are programmed using a master intercom station and a DNA100/PC.
The DNA934P is compatible with CB901EX, RM5000EX and CB901CA.
OPERATION
The DNA934P Interface transfers calls from the intercom exchange to the telephone network.
p to 4 telephone numbers can be programmed. If a Busy or Ring-No-Answer is encountered then the
next number on the list is dialed. If all 4 numbers are busy or no one answers then the dialer will
continue to dial all 4 numbers until one of the numbers answers.
When the dialed telephone answers, a recorded message is played to that telephone. This message
will identify the name and address of the building where the call is coming from. Following this
message the called party will receive a message identifying the intercom number that placed the call.
The final message instructs the telephone operator to accept the call by dialing #1 or to refuse the call
by hanging up. These messages are repeated 3 times (programmable) or until the #1 is dialed. If the
telephone operator does not dial #1 or hang up then the next number on the list is dialed
automatically. While in conversation the telephone operator may replay the caller ID message by
dialing #2.
Page 5
Ring-Master

DNA934P Telephone Dialer with Recorder April 2017
Page 6
Ring-Master

April 2017 Telephone Dialer with Recorder DNA934P
INSTALLATION
The DNA934P Interface connects to the telephone line on modular connector J3.
Modular connector J1 connects to the Ring-Master Central Exchange for Power, Voice and Data.
J1 Connector:
se a modular jack with screw terminals (KB171) for external connections.
Connect the external jack to J1 using a modular cable (BF640A).
Pin Description
1 - No Connection
2 - + power input (+ 24 VDC)
3 - Data +
4 - Intercom audio (b)
5 - Intercom audio (a)
6 - Data -
7 - - power input
8 - External Alarm
Connect Intercom Audio, 24VDC and RS485 Data to the Central exchange using 3 twisted
pair cable (unshielded).
Page 7
Ring-Master
Illustration 1: DNA934P rear view
123456 12345678
J3 J1
PBX
Ring-Master
RM EXCHANGE

DNA934P Telephone Dialer with Recorder April 2017
J3 Connector:
se a modular jack with screw terminals (KB161) for connection to the telephone line.
Connect the external jack to to J3 using a modular cable (BF961).
Pin Description
1 - +24V output to external relay for Tip/Ring transfer
2 - No Connection
3 - Tip
4 - Ring
5 - No Connection
6 - Ground output to drive external relay
Connect the telephone line to pin 3/4 (twisted pair).
Front Panel Switches and Indicators:
Indicators:
R N - Processor is active
MASTER - The Master of the RS485 Network will have this LED on.
TX - Transmit Data to the Network
RX - Receive Data from the Network
RM ON - Intercom port is active
RING IN - Telephone line is ringing
CALL PROGRESS -Audio detected on the telephone line
OFF HOOK - Telephone line off hook
Page 8
Ring-Master
Illustration 2: DNA934P front view
SW2 SW3RESET
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
MASTER
R N
TX
RX
CALL PROGRESS
OFF HOOK
RM ON
RING IN
DNA934P

April 2017 Telephone Dialer with Recorder DNA934P
Switches:
SW2 - Network Address.
RESET - Reset of Telephone interface.
SW3 - Options:
1. OFF
2. Exchange Interface for remote Conference Telephone Monitoring
3. Exchange Interface for remote Conference Handset
4. Interface at remote Conference Handset
5. OFF
6. OFF
7. OFF
8. Telephone Line Supervision
Resetting Battery RA :
When the system is first installed the DNA934P must be reset before any configuration is
done.
Procedure
1. Set all 8 DIP switches in SW2 to OFF
2. Push and release RESET switch
3. Wait for MASTER LED to start blinking (reset complete)
4. Set Network address
5. Push and release RESET switch
Page 9
Ring-Master

DNA934P Telephone Dialer with Recorder April 2017
CONFIG RATION
One DNA100 and a PC is used for programming the DNA934P. The DNA100 sets up a link to
the DNA934P and the PC is used to input configuration commands. The configuration is
stored in battery back up memory in the DNA934P. When the system is first installed the
DNA934P must be reset before any configuration is done (see page 4).
Type fonts:
boldface type indicates user input
courier font indicates output
Prompt:
<> Angle brackets enclose input parameters
$ Hexadecimal value
Error Handling:
Misspelled command input will give the following message: Unknown Command
Parameter errors will print ERROR: then prompt for the parameter again.