Riiot blue Manual de usuario

ENFR
blue by Riiot
QUICK START GUIDE

EN » Quick start guide ....................................... 1
FR » Guide de démarrage rapide ....................... 11

1QUICK START GUIDE
EN
Thanks for choosing Blue by Riiot.
For more information consult the online user manual and view our
videos on our website www.blueconnect.io (help).
Introduction
A. Overview
Blue by Riiot continuously measures the key parameters of your
swimming pool (temperature, pH, ORP/Redox, conductivity). It also
informs you of the external temperature and weather based on your
geolocation. The results of this analysis are then communicated to you
via notications on the ”Blue Connect“ app (available on smartphone
and tablet, compatible with Android™ and iOS). If the device detects
that one of the parameters is incorrect, an alert informs you of this
status and provides you with the instructions to follow to regulate and
stabilize this parameter in order to maintain a healthy and balanced
water.
Blue by Riiot measures the following:
» Water temperature (°C, °F): An elevated temperature reduces
the efficiency of the disinfectant product and promotes the
development of microorganisms.
» pH (hydrogen potential): this value measures the acidic or basic
character of a medium. pH contributes to the effectiveness of the
disinfectant.
» ORP/REDOX (measurement of active chlorine in mV): The ORP
measure is reflected in milli-volts (mV). The measurement taken
by the ORP probe of your Blue by Riiot is a voltage in milli-volts
(mV), which represents the more or less oxidizing nature of your
pool’s water.
» Conductivity1 (μS): Measurement of the concentration of inorganic
salts in the water by the ability of the latter to conduct electricity.
1For salt pools, salinity (more precisely the total salt content) is measured on
the conductivity basis. The salinity measured by the Blue by Riiot is expressed
in grams per liter (g/L) of TDS (Total Dissolved Solids). This is an estimate of [...]

2QUICK START GUIDE
EN
B. Precautions for use
» Do not use Blue by Riiot for anything other than water analysis.
» Blue by Riiot is not a toy. Avoid shocks as they may damage it.
» Keep Blue by Riiot out of reach of children when handling it
(e.g. calibration and standby) due to the use of chemicals. Store
calibration products out of reach of children.
» Do not open the top part of the device (except when replacing
the battery). Follow carefully the battery replacement instructions.
Damage caused by liquids is not covered by the warranty.
» Do not open the bottom part of the device containing the probe
(except when replacing the probe). Follow carefully the probe
replacement instructions. Damage caused by liquids is not
covered by the warranty.
» Make sure not to leave the probe out of the water without the
storage cap filled with KCl (saturated potassium chloride), pH4 or,
as a last resort, running water with a good amount of cooking salt.
» Do not use demineralized water in the storage cap.
» Make sure the top part of the unit is out of the water to allow the
communication system to work.
» Do not leave Blue by Riiot in water with a temperature below 5°C
or above 50°C.
» Keep the Blue by Riiot serial number and key2.
» Store Blue by Riiot sheltered from frost.
1[...] the total amount of dissolved species in the pool, based on the assumption
that the main species is sodium chloride (NaCl or cooking salt). Sodium chloride
increases the conductivity of your pool water depending on its concentration.
An estimate of the sodium chloride level based on the conductivity will deviate
even more if other unknown salts are present in your pool. This deviation can be
checked using colorimetric detection strips specic for sodium chloride.
2On the back of the quick start guide and on Blue by Riiot’s storage cap.

3QUICK START GUIDE
EN
Content of the box
Blue by Riiot analyser: Delivered secured on
the storage cap to protect the probe during
transportation. The probe is immersed in KCI
(saturated potassium chloride), which assures its
protection.
The storage cap: Used to transport the probe
out of the water or to keep the sensors
immersed during an extended storage (in winter
for example).
The usage cap: Must always be mounted on the
device before placing it in water. It protects the
sensors from any damage.
Cord: Allows to x the device to a point of
attachment.
Quick start guide: Helps you with the device
start-up.

4QUICK START GUIDE
EN
App installation
Activate the Internet (Wi-Fi or 4G) and Bluetooth® on your
smartphone or tablet.
Note: Stay close to your device throughout the whole Blue
by Riiot activation process.
Download the free “Blue Connect” app on App Store® and
Google Play™.
Authorize notications to benet from the alerts.
Login to “Blue Connect”:
» via Facebook®.
» via Twitter®.
» via your email address.
Create your swimming-pool: enter your swimming pool’s
characteristics.
Note: You can view or modify the characteristics of your
swimming pool at any time in “Settings” » “My Pool”.
1.
2.
3.
4.
5.

5QUICK START GUIDE
EN
Note: To add a second swimming pool in the app, press the name of
the active swimming pool and select “+”.
The application is divided in four main sections3:
Dashboard: Informs you of Blue by Riiot’s status, the water
temperature, the local weather and the quality of your pool
water.
Table of values: Informs you precisely of the values
measured by Blue by Riiot, trends and ideal values.
Maintenance guide: Advises you on the operations to
perform to maintain the quality of the water in your pool.
Settings: Allows you to congure the settings for your
pool and Blue devices, as well as have access to help and
technical support.
Blue by Riiot installation
A. How to start up Blue by Riiot?
In the app, in “Settings” » “My Blue Connect”, press “Add a
Blue Connect” and insert the code (key) and the three last
digits of the serial number (SN), which can both be found
on the back of the start guide or on the storage cap of the
device.
3The app is subject to continual improvements and changes.
1.

6QUICK START GUIDE
EN
To start the device, you must activate it. The top of the device
has a wave shape. Place the trough of the wave towards
yourself and shake it sharply. You will hear two beeps,
meaning that the initial activation was successful.
Press “ok” to nalize the activation process. The device
is now linked to your account and permanently linked to
Sigfox®4network.
4Sigfox® is a telecommunications network specialised in the Internet of Things.
It is a cellular network that does not interfere with domestic Wi-Fi. You can
check if your swimming pool is covered by the Sigfox® network by visiting
www.sigfox.com/coverage. Blue by Riiot uses Sigfox® to transfer data to
your smartphone.
2.
3.

7QUICK START GUIDE
EN
Place Blue by Riiot upright on the storage cap and
unscrew it.
Empty the storage cap, rinse in clear water and store it.
Rinse the probe in clear water and place the usage cap on
the external part of the device to protect the probes.
4.
5.
6.

8
EN
Place Blue by Riiot in the swimming pool:
In the pool: Leave it oating in the pool. If needed, you can
secure it by xing it to a point of attachment with the cord
and the rubber ring.
Note: Make sure the device is in vertical position and the top
part out of the water to allow a correct communication.
B. Notes
» Do not leave the sensor exposed to air.
» The Sigfox® network connects automatically and sends
measurements at regular intervals.
» The sensor may take a few hours to stabilise its parameters after its
first immersion in the swimming pool.
» In case of non-existent Sigfox® coverage, there are two options:
» Blue by Riiot operates in Bluetooth®. In such case, you must
take daily Bluetooth® measurement(s) for the device to perform
its analyser work.
» Blue Extender allows Blue by Riiot to connect to your Wi-Fi
network.
Feel free to watch our Blue by Riiot start-up video available on
www.blueconnect.io (help).
7.
QUICK START GUIDE
Otros manuales para blue
2
Tabla de contenidos
Idiomas:
Otros manuales de Instrumento de medición de Riiot
Manuales populares de Instrumento de medición de otras marcas

Endress+Hauser
Endress+Hauser Proline Promag 50 Especificaciones técnicas

Siemens
Siemens SITRANS F Coriolis FCT030 Manual de lista de piezas

KLINGER
KLINGER CMF V Series Manual de usuario

EXFO
EXFO FTB-2 Manual de operación y mantenimiento

Keysight
Keysight M8290A Manual de usuario

ADTEK
ADTEK MW-5 Manual de usuario












