REMKO ATR-Smart-Web Manual de usuario

Operating manual
Read the instructions prior to performing any task!
REMKO room temperature controller
ATR-Smart-Web and ATR-Smart-Basic
0146-2016-09 Edition 1, en_GB

Translation of the original operating manual
Read these operating instructions carefully before commis-
sioning / using this device!
These instructions are an integral part of the system and must
always be kept near or on the device.
Subject to modifications; No liability accepted for errors or mis-
prints!

Table of contents
1 Safety and usage instructions............................................................................................................. 4
1.1 General safety notes....................................................................................................................... 4
1.2 Identification of notes...................................................................................................................... 4
1.3 Personnel qualifications.................................................................................................................. 4
1.4 Dangers of failure to observe the safety notes................................................................................ 4
1.5 Safety-conscious working............................................................................................................... 4
1.6 Safety notes for the operator........................................................................................................... 5
1.7 Safety notes for installation, maintenance and inspection.............................................................. 5
1.8 Unauthorised modification and changes......................................................................................... 5
1.9 Intended use................................................................................................................................... 5
1.10 Warranty........................................................................................................................................ 5
1.11 Transport and packaging............................................................................................................... 6
1.12 Environmental protection and recycling........................................................................................ 6
2 Unit description..................................................................................................................................... 7
2.1 Description...................................................................................................................................... 7
3 Operation............................................................................................................................................... 8
3.1 Instructions for the user................................................................................................................... 8
3.2 Method of operation...................................................................................................................... 10
3.3 Management of the GPC Smart Processor .................................................................................. 34
4 Electrical connection.......................................................................................................................... 37
5Troubleshooting.................................................................................................................................. 41
6 Index..................................................................................................................................................... 43
3

1 Safety and
usage instructions
1.1 General safety notes
Carefully read the operating manual before com-
missioning the units for the first time. It contains
useful tips and notes such as hazard warnings to
prevent personal injury and material damage.
Failure to follow the directions in this manual not
only presents a danger to people, the environment
and the system itself, but will void any claims for
liability.
Keep this operating manual and the refrigerant
data sheet near to the units.
1.2 Identification of notes
This section provides an overview of all important
safety aspects for proper protection of people and
safe and fault-free operation.The instructions and
safety notes contained within this manual must be
observed in order to prevent accidents, personal
injury and material damage.
Notes attached directly to the units must be
observed in their entirety and be kept in a fully
legible condition.
Safety notes in this manual are indicated by sym-
bols. Safety notes are introduced with signal words
which help to highlight the magnitude of the danger
in question.
DANGER!
Contact with live parts poses an immediate
danger of death due to electric shock. Damage
to the insulation or individual components may
pose a danger of death.
DANGER!
This combination of symbol and signal word
warns of a situation in which there is immediate
danger, which if not avoided may be fatal or
cause serious injury.
WARNING!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may be fatal or cause
serious injury.
CAUTION!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may cause injury or mate-
rial and environmental damage.
NOTICE!
This combination of symbol and signal word
warns of a potentially hazardous situation,
which if not avoided may cause material and
environmental damage.
This symbol highlights useful tips and recom-
mendations as well as information for efficient
and fault-free operation.
1.3 Personnel qualifications
Personnel responsible for commissioning, opera-
tion, maintenance, inspection and installation must
be able to demonstrate that they hold a qualifica-
tion which proves their ability to undertake the
work.
1.4 Dangers of failure to observe
the safety notes
Failure to observe the safety notes may pose a risk
to people, the environment and the units. Failure to
observe the safety notes may void any claims for
damages.
In particular, failure to observe the safety notes
may pose the following risks:
nThe failure of important unit functions.
nThe failure of prescribed methods of mainte-
nance and repair.
nDanger to people on account of electrical and
mechanical effects.
1.5 Safety-conscious working
The safety notes contained in this manual, the
existing national regulations concerning accident
prevention as well as any internal company
working, operating and safety regulations must be
observed.
REMKO room temperature controller
4

1.6 Safety notes for the operator
The operational safety of the units and compo-
nents is only assured providing they are used as
intended and in a fully assembled state.
nThe units and components may only be set up,
installed and maintained by qualified per-
sonnel.
nProtective covers (grille) over moving parts
must not be removed from units that are in
operation.
nDo not operate units or components with
obvious defects or signs of damage.
nContact with certain unit parts or components
may lead to burns or injury.
nThe units and components must not be
exposed to any mechanical load, extreme
levels of humidity or extreme temperature.
nSpaces in which refrigerant can leak sufficient
to load and vent. Otherwise there is danger of
suffocation.
nAll housing parts and device openings, e.g. air
inlets and outlets, must be free from foreign
objects, fluids or gases.
nThe units must be inspected by a service tech-
nician at least once annually. Visual inspec-
tions and cleaning may be performed by the
operator when the units are disconnected from
the mains.
1.7 Safety notes for installation,
maintenance and inspection
nAppropriate hazard prevention measures must
be taken to prevent risks to people when per-
forming installation, repair, maintenance or
cleaning work on the units.
nThe setup, connection and operation of the
units and its components must be undertaken
in accordance with the usage and operating
conditions stipulated in this manual and comply
with all applicable regional regulations.
nLocal regulations and laws such as Water
Ecology Act must be observed.
nThe power supply should be adapted to the
requirements of the units.
nUnits may only be mounted at the points pro-
vided for this purpose at the factory. The units
may only be secured or mounted on stable
structures, walls or floors.
nMobile units must be set up securely on suit-
able surfaces and in an upright position. Sta-
tionary units must be permanently installed for
operation.
nThe units and components should not be oper-
ated in areas where there is a heightened risk
of damage. Observe the minimum clearances.
nThe units and components must be kept at an
adequate distance from flammable, explosive,
combustible, abrasive and dirty areas or
atmospheres.
nSafety devices must not be altered or
bypassed.
1.8 Unauthorised modification
and changes
Modifications or changes to units and components
are not permitted and may cause malfunctions.
Safety devices may not be modified or bypassed.
Original replacement parts and accessories
authorised by the manufactured ensure safety. The
use of other parts may invalidate liability for
resulting consequences.
1.9 Intended use
The unit is used to operate the indoor units from a
remote location.
Any different or additional use shall be classed as
non-intended use. The manufacturer/supplier
assumes no liability for damages arising from non-
intended use. The user bears the sole risk in such
cases. Intended use also includes working in
accordance with the operating and installation
instructions and complying with the maintenance
requirements.
The threshold values specified in the technical
data must not be exceeded.
1.10 Warranty
For warranty claims to be considered, it is essential
that the ordering party or its representative com-
plete and return the "certificate of warranty" to
REMKO GmbH & Co. KG at the time when the
units are purchased and commissioned.
The warranty conditions are detailed in the "Gen-
eral business and delivery conditions". Further-
more, only the parties to a contract can conclude
special agreements beyond these conditions. In
this case, contact your contractual partner in the
first instance.
5

1.11 Transport and packaging
The devices are supplied in a sturdy shipping con-
tainer. Please check the equipment immediately
upon delivery and note any damage or missing
parts on the delivery and inform the shipper and
your contractual partner. For later complaints can
not be guaranteed.
WARNING!
Plastic films and bags etc. are dangerous
toys for children!
Why:
- Leave packaging material are not around.
- Packaging material may not be accessible to
children!
1.12 Environmental protection
and recycling
Disposal of packaging
All products are packed for transport in environ-
mentally friendly materials. Make a valuable contri-
bution to reducing waste and sustaining raw mate-
rials. Only dispose of packaging at approved
collection points.
Disposal of equipment and components
Only recyclable materials are used in the manufac-
ture of the devices and components. Help protect
the environment by ensuring that the devices or
components (for example batteries) are not dis-
posed in household waste, but only in accordance
with local regulations and in an environmentally
safe manner, e.g. using certified firms and recy-
cling specialists or at collection points.
REMKO room temperature controller
6

2 Unit description
2.1 Description
The room temperature controllers ATR-Smart-Web
and ATR-Smart-Basic can be identified by the
identification plate on the front of the unit and the
data plate on the outside of the packaging. When
contacting the repair service, please always state
the model of the room temperature controller and
the serial number. The difference between the
"ATR-Smart-Web" model and the "ATR-Smart-
Basic" model is explained later in this manual.
A
B
A: ATR-Smart-Web
B: ATR-Smart-Basic
Technical properties
The remote controls from the ATR-Smart-Web or
ATR-Smart-Basic series are independent control-
lers that can be used to control many different sys-
tems. They are suitable for controlling a system
with one zone in which one to a maximum of 32
units can be installed simultaneously. They can be
used as a set-up device during initial installation or
connected as optional accessories to the units
equipped with GPC Smart processors, namely:
nNew series of GPC condensing units
The circuit CANNOT be used with units
equipped with processors older than those
specified above.
Main features of the ATR-Smart series controllers:
nEasy connection to the unit via two electrical
wires.
nComplete management of the operating
parameters of the processors of the connected
units.
nPossibility of installing up to 3 room sensors in
addition to those mounted in the unit.
nTFT colour monitor, 4.3 inch touch screen (res-
olution 480x272 pixels)
nMultilingual user program (Italian, English,
Spanish, French, German, Dutch, Czech,
Polish, Romanian).
nComplete management of the remote control
and all functions via the web (only with ATR-
Smart-Web).
Operating temperature: -15°C to +60°C
7

Unit supply
The room temperature controllers from the ATR-
Smart-Web series or ATR-Smart-Basic series are
supplied with 12 V DC (+10%/-15%) and a lithium
backup battery (type CR2032) is installed inside
them. The backup battery has a service life of
about 2 years of continuous non-supply, after
which time the date, time and day parameters must
be reset and the battery replaced if necessary
when the room temperature controller is switched
on again. To replace the backup battery, remove
the back cover of the remote control and discon-
nect the power terminals(M1). Carefully unscrew
screw A at the bottom left (Fig. 1) so as not to
damage the NTC sensor of the unit. Remove and
replace battery B as shown in the illustration
below. Replace the washer and secure it with the
screw; reconnect the M1 power terminal and close
the rear cover after the operation.
A
BCR 2032
M1
Fig. 1: Unit supply
A: Screw
B: Battery (CR 2032)
M1: Terminal
3 Operation
3.1 Instructions for the user
The instructions contained in this manual refer
to the remote controls ATR-Smart-Web and
ATR-Smart-Basic, which use firmware version
2.15.
10:15 Lun 01 GenHOME
SET: OFF 20.0 °C
Fig. 2: HOME start screen
The remote control has a TFT LCD 4.3 inch touch
screen colour display with 480x272 pixel resolu-
tion. The start page (HOME) is laid out as follows:
10:15 Lun 01 GenHOME
SET: 18°C 20.0 °C
000 %
2
1
3
10
4 5
6
7
8
9
11
Fig. 3: Layout of the HOME start screen
1 Temperature setpoint
2 Time
3 Fault messages section
4 Menu page
5 Date
6 Reference temperature
7 Operating section
8 GPC Smart menu
REMKO room temperature controller
8

9 PID modulation
10 Main menu
11 Status section
The following is the list of icons that may be
present within the various sections that make up
the HOME page, with descriptions.
20.0
SET: 18.0°C
10:15 Lun 01 GenHOME
°C
000 %
1
3b
11
3a 3c
7b7a 7c 7d
Fig. 4: Icons on the HOME start screen
1 Applicable setpoint
3Fault messages
3a
!
Unit error
3b
E2P
Memory data loss
3c Mains power fault
7a Operating mode
Manual
Automatic (switching times)
7b Method of operation
Heating
Ventilation
Air conditioning (only with hybrid)
Hot water (only with hybrid)
OFF
7c Operating mode settings
Comfort (Cm)
ECO
Economy (Ec)
Anti-freeze protection (An)
7d
Holiday mode
OFF
TMP
Temporary OFF
11 Operating status
Burner ON
Fan ON
OK
Setpoint reached
ID1
ID1 open
9

3.2 Method of operation
Main menu
The main menu of the room temperature controller
is called up via the key on the start screen
(HOME). The menu consists of the following sec-
tions:
A TIMER
B MODE
C SETTINGS
D SETTINGS
E HYBRID (only with hybrid systems)
F SYSTEM
10:15 Lun 01 GenMENU
A
F
C
B
E
D
10:15 Lun 01 GenHOME
SET: 18°C 20.0 °C
!
Fig. 5: Main menu
When scrolling within the screen pages of the
room temperature controller, the keys that can be
used within the displayed section appear on the
bottom line. If there are any errors or faults, the
symbol , for running error message, appears
next to the time and remains visible until the error
message is reset. The keys have the following
main functions:
HOME Return to HOME page
BACK Return to the higher menu
level
OK
OK Data confirmation / save data
OPTION Changing the settings
Pressing the key next to the items of one of the
various menus calls up the corresponding sub-
menu. Pressing the key next to the items of
one of the various submenus calls up the settings
for the corresponding submenu.
Settings
When using the room thermostat for the first time
(and after any memory loss), check that the param-
eters of the "SETTINGS" menu are correct.
The Settings key in the main menu calls up this
menu, which includes the following submenus:
nDate
nTime
nDay
nLanguage
nContrast
nScreensaver
nInfo
REMKO room temperature controller
10
Este manual sirve para los siguientes modelos
1
Tabla de contenidos

















