Relens TLS MF4.1 Manual de usuario

User manual
875345
MF4.1 Multiformat Switch 4/1

875345 MF4.1
Relens Gmb Contact: info@relens.de 2
Table of contents
Safety information .............................................................................................. 3
Introduction ........................................................................................................ 4
Features ............................................................................................................. 4
Panel Description............................................................................................... 5
Application Diagram .......................................................................................... 7
Specifications ..................................................................................................... 8
Package Contents ............................................................................................. 8
RS232…………………………………………………………………………………9
Phoenix Connection Diagram……………………………………………………..11
Maintenance ...................................................................................................... 9
Warranty Policy ................................................................................................ 12
Limitations of Warranty .................................................................................... 12
Exclusive Remedies ........................................................................................ 13
RMA Policy ...................................................................................................... 13
Standard Replacement .................................................................................... 14
Once you have obtained an RMA number ....................................................... 14
Please note: ..................................................................................................... 15
Warranty .......................................................................................................... 15
Return and RMA Policies ................................................................................. 16

875345 MF4.1
Thank you for purchasing this product. For optimum performance and safety,
please read these instructions carefully before connecting, operating or
adjusting this product. Please keep this manual for future reference.
SURGE PROTECTION EVICE RECOMMEN E
This product contains sensitive electrical components that may be damaged by
electrical spikes, surges, electric shock, lightning strikes, etc. Use of surge
protection systems is highly recommended in order to protect and extend the
life of your equipment.
Safety information
To reduce the risk of electric shock, do not expose this product to
rain or moisture
Do not modify the wall plug. Doing so will void the warranty and
safety features
If the wall plug does not fit into your local power socket, hire an
electrician to replace your obsolete socket.
This equipment should be installed near the socket outlet and the
device should be easily accessible in the case it requires
disconnection

875345 MF4.1
Relens Gmb Contact: info@relens.de 4
Introduction
The MF4.1 is a Multiformat switcher with DMI, VGA and Display Port
input to DMI output with audio de-embedded. It can also support RS232,
Contact Closure for remote control.
Features
• Multi-format inputs for VGA/DP/2 DMI;
• Support DP 1.2 with 4K@30 z;
• Support DMI 2.0 with 4K@30 z or 4K@60 z 4:2:0;
• DCP compliant;
• Optional internal EDID or live EDID;
• Support RS232/Button/Contact closure for switching;
• Support Auto/Manual switching mode;
• Analog audio de-embedded at the output;
• Support output mute function;
• Support power standby mode;
• Status LED for all connections on front
;

875345 MF4.1
Panel escription
Front Panel:
1. H -O:Led solid when output to display, flashing with connection to display but
without output signal, off mean no display connected;
2. H MI-A:Led solid when selected, flashing when signal present, off mean no
input signal;
3. H MI-B:Solid LED when selected, flashing when signal present, off mean no
input signal;
4. VGA:Solid LED when selected, flashing when signal present, off mean no input
signal;
5. P:Solid LED when selected, flashing when connecting well but not selected,
off mean no input;
6. PWR: Solid Red when power on;
7. SELECT: Button for switching input signal. Pressing for 3-5secondor longer to
toggle EDID selection。 D3-O flash once to indicate switching to internal EDID,
D-O flash 3 times mean switching to external display EDID.

875345 MF4.1
Relens Gmb Contact: info@relens.de 6
Panel escription
Rear Panel:
1. Power: DC Power Input;
2. VGA: VGA Input
3. AU : VGA Audio Input;
4. P: Display PortInput;
5. H MI-A/B: DMI Inputs;
6. H MI: DMI Output;
7. AU : Analog Audio Output;
8. Phoenix Port: RS232 and Contact Closure with LED indicator.

875345 MF4.1
Relens Gmb Contact: info@relens.de 8
Specifications
DMI Compliance DMI 2.0 4K
DP Compliance DisplayPort 1.2 4K
VGA Compliance VESA + Audio
DCP Compliant Yes
Audio Output Connectors 1x 3.5mm stereo earphone jack (L/R)
EDID Pass Through
Dimensions(W x D x ) 190 mm x 103 mm x 29 mm
Weight 0.33 KG
Operating Temperature 0°C to 55°C
Storage Temperature - 20°C to 85°C
Power Supply 5V/1A DC
Package Contents
1×Base Unit MF4.1
1×5V 2A DC power adapter
1×User manual
2×Wall mounting bra ket
1.

875345 MF4.1
RS232-Control
Command String Information Example Example String
Example
Response
Baud Rate
Setup
Command
&Bab<cr>
a=baud rate
=2400,4800,
9600,14400,
19200,38400,
56000,57600,
115200
b=bits,
parity =8N,
8E,8O,9N,
9E,9O
Set RS232
Port Baud
Rate to
9600,8,N
&B9600,8,N<cr
>
^B9600,8,N
<cr>
Switching
VGA+Audio
from input 1
to output
&Ra<cr> a= V
V for VGA
Switching
VGA+
Audio from
input 1 to
output
&RV<cr> VGA
Switching DP
from input 2
to output
&Ra<cr> a= P
P for DP
Switching
DP from
input 2 to
output
&RP<cr> DP
Switching
DMI-A from
input 3 to
output
&Ra<cr>
a= A
A for DMI-A
Switching
DMI-A
from input
3 to output
&R A<cr> DMI-A
Switching
DMI-B from
input 4 to
output
&Ra<cr>
a= B
B for DMI-B
Switching
DMI-B
from input
4 to output
&R B<cr DMI-B
Mute the
DMI Output &Va<cr>
a = 0 , 1
0 = Mute
Output, 1 =
UnMute Output
Mute the
DMI
Output
&V0<cr> Mute On
Query Active
Route &R?<cr>
Request
ing the
active
&R?<cr>
Channel
status
Current

875345 MF4.1
Relens Gmb Contact: info@relens.de 10
route
status
Input is
VGA.
Switching
mode &Ma<cr>
a = 0, 1
0 = Manual
switching
mode , 1 =
Auto switching
mode
Set Auto
switching
mode
&M0<cr> Manual
Switch
Requesting
switching
mode,
Feedback
&Ma<cr>
a = ?
?= State of the
query
Request
ing
switching
mode,
Feedback
&M?<cr>
Manual
Mode
Switching
EDID
Management
&Ea<cr>
a = ext , int
ext = External
Display EDID,
int = Internal
preset EDID , ?
= Switching to
preset EDID
Set preset
EDID
&Eint<cr>
EDID:
internal
Requesting
the EDID
Status,
Feedback
EDID?<cr>
a = ?
? = Switching
to preset EDID
Request
ing the
EDID
Status,
Feedback
EDID?<cr> EDID:
external
Note: The default baud rate 9600.