Regency Fireplace Products 340-900 Guía de inicio rápido

918-432a
09/06/05
Owner's &
Installation
Manual
FPI Fireplace Products International Ltd.
6988 Venture St., Delta, BC
Canada, V4G 1H4
FOR YOUR SAFETY
What to do if you smell
gas:
Do not try to light any
appliance
Do not touch any electri-
cal switch: do not use
any phone in your build-
ing.
Immediately call your
gas supplier from a
neighbour's phone. Fol-
low the gas supplier's
instructions.
If you cannot reach your
gas supplier, call the fi re
department.
WARNING:
Improper installation, adjustment,
alteration, service or maintenance
can cause injury or property damage.
Refer to this manual. For assistance
or additional information consult an
authorized installer, service agency
or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
fl ammable vapours and liquids in
the vicinity of this or any other ap-
pliance.
E33 GAS INSERT
ZERO CLEARANCE KIT
KIT # 340-900
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
fire-parts.com

2
E33 Gas Insert Zero Clearance Kit
TABLE OF CONTENTS
GAS INSERT ZERO CLEARANCE KIT
CONTENTS
PAGE
General Information
..........................................................................
3
E33 Insert Zero Clearance Kit Specifi cations
.....................................
3
Clearances to Combustibles
..............................................................
4
Combustible Mantle Clearances
........................................................
5
Framing
.............................................................................................
6
Zero Clearance Kit Assembly
.............................................
6
Assemble the Cabinet
........................................................
6
Attach the Cabinet to the Framing
...................................
10
Install the Insert
.............................................................
10
Venting Introduction
.......................................................................
11
Simpson Dura-Vent Components List
............................
11
fire-parts.com

3
E33 Gas Insert Zero Clearance Kit
E33 Gas Insert Zero Clearance Kit Specifi cations
GENERAL INFORMATION
This kit consists of factory built parts that require minimal assembly to form the Zero Clearance enclosure for the E33 Gas
Insert. The enclosure can then be fi xed into a framed combustible construction, and a standard Simpson Dura-Vent Direct Vent
GS System installed on the assembly for the required venting. The insert can be installed later. The faceplate will normally
overlap on top of the fi nished wall.
INSTALLATION
LIP
fire-parts.com

4
E33 Gas Insert Zero Clearance Kit
INSTALLATION
CLEARANCES TO COMBUSTIBLES
The clearances for the Zero Clearance Kit are 0" to combustibles (back, side and fl oor) but when planning your installation
review the clearances required for the Insert (see below) after it is installed in the Zero Clearance Kit.
Warning: Combustible facing materials must not extend inside the 1/2" (13mm) lip at the edge of the face panels.
Any non-combustible facing materials (such as ceramic tile or masonry face brick) up to 1-1/2" (38mm) thick may be used to
fi nish the area inside the 1/2" (13mm) lip on the face panels. Non-combustible tile backer board such as Wonderboard or Durock
, or metal lath or screen may be fastened directly to the front of the face panels to provide a base for attaching facing materials
if needed. The Zero Clearance Kit must be installed on a fl at, solid, continuous surface (e.g. wood, metal, concrete).
From Unit
Sides
*A
12" (305mm)
Ceiling
B
47" (1194mm)
Min. Mantel Height
C
23" (584mm)
Mantel
Depth
D
3-1/2" (89mm)
Alcove Width
E
76" (1930mm)
Alcove Depth
F
36" (914mm)
* Alcove side wall must have a minimum of 12" (305mm)
clearance on one side.
fire-parts.com

5
E33 Gas Insert Zero Clearance Kit
Because of the extreme heat this fi replace emits, the mantel clearances are critical.
Combustible mantel clearances from top of unit are shown in the above diagrams.
Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered
with a non-combustible board.
Mantel can be installed anywhere in shaded area or higher using the above scale.
Note: Ensure the paint that is used on the mantel and the facing is “heat resistant” or the paint may discolour.
COMBUSTIBLE MANTEL CLEARANCES
INSTALLATION
fire-parts.com

6
E33 Gas Insert Zero Clearance Kit
INSTALLATION
Right Side
Base
Section
screw
screw
Left Side
Base
Section
screw
screw
Do not install the third screw until
the back panel is installed.
FRAMING
1)
The cabinet face panels have a 1/2" (13mm) lip to defi ne the zones for
combustible and non-combustible facing materials: outside the lip, any
material up to 1/2" (13mm) may be used; inside the lip, only non-combus-
tible materials may be used (with a maximum thickness of 1-1/2" (38mm)).
The kit may be installed directly on and/or against standard combustible
building materials. Refer to Page 3 for diagram.
2)
Frame in the enclosure for the Kit with framing material. The framed
opening for the assembled kit is 52" (1321 mm) high x 50-1/4" (1276
mm) wide x 18-1/2" (470 mm) deep. See diagram.
If the interior of the cabinet framing is fi nished (with sheet rock,
for example), The dimensions given are from the inside of the
fi nished surfaces. The ceiling inside the framed enclosure
should be a minimum of 55-1/2" (1410mm) from the base.
3)
For exterior walls, use a vapour barrier and insulate the enclo-
For exterior walls, use a vapour barrier and insulate the enclo-
sure to the same degree as the rest of the house, or according
sure to the same degree as the rest of the house, or according
to local installation codes. In colder climates, if the heater is
to local installation codes. In colder climates, if the heater is
to be installed against an exterior wall or chase, insulate the exterior walls according to local installation codes.
to be installed against an exterior wall or chase, insulate the exterior walls according to local installation codes.
ZERO CLEARANCE KIT ASSEMBLY
ZERO CLEARANCE KIT ASSEMBLY
Parts Included with Kit:
2 Back sections
2 Side
1 Base
1 Top
2 Front Face Side Panel
1 Front Face Top Panel
2 Top Standoffs
2 Extension Legs
All pieces join together using the sheet metal screws that are
provided with the kit.
Assemble the Cabinet
1) Assemble the Sides and Base sections. The Side sections
fi t inside the lip of the Base section. The wider fl ange on
the Side section is on the front of the kit.
Secure with 2 screws on each side. Leave the 3rd screw
(closest to the rear) until the Back section is attached.
fire-parts.com

7
E33 Gas Insert Zero Clearance Kit
INSTALLATION
Secure to the Lower Back Section with 4 screws (from the
inside). See Below.
From the outside, secure with 2 screws on each side.
See Below.
2) Set the assembled Side and Base sections upright. Slide
the Lower Back (the section with 4 holes) down the
inside
of Side fl anges (make sure the 4 holes are closest to the
fl oor - see photo).
Right
Side
screw
Attach with 2 screws on the side. Repeat for Left Side
Attach with 11 screws on the sides and bottom.
3) Slide the Upper Back Section down the
inside
of the Side
fl anges.
screw
screw
fire-parts.com

8
E33 Gas Insert Zero Clearance Kit
INSTALLATION
5) Assemble the 2 top Standoffs. The Top Standoffs are
shipped fl at and must be folded at the bend lines into the
correct shape.
Attach the Right Standoff to the top using the 4 holes at
the front right of the top. Install the Left Standoff to the 4
holes at the front left.
Secure with 6 screws on the back. Leave the top screw
holes until the top is attached.
4) Install the Top. Hold the top so that the large vertical
fl ange is at the front of the cabinet and fi t it down over
the Side/Back assembly. Secure the top to the assembly
using 3 screws on each side and 5 through the back and
8 on top.
fire-parts.com

9
E33 Gas Insert Zero Clearance Kit
INSTALLATION
8) Assemble the Face Panels (left, right, and top), all 3 Face
panels are installed loosely, and then attached to the
cabinet body.
b) Fit the assembled Side & Top Face Panels to the front of
the cabinet and secure with 19 screws.
7) Drop the Flue Adaptor assembly into the hole on the top
section.
Secure the fl ue adaptor box to the top with
4 screws from the top.
a) Secure the Left and Right Panels to the top with 1 screw
each. Make sure that the outside edges are aligned.
6) Assemble the fl ue adaptor box. Slide the fl ex vent pipe
over the small vent opening on the base of the adaptor
box and secure with a clamp. Repeat for the 2nd fl ex vent
pipe.
EXHAUST
INTAKE
fire-parts.com

10
E33 Gas Insert Zero Clearance Kit
INSTALLATION
Install the Insert
1) Slide the unit into the cabinet on top of the bottom stand-
offs.
2) Connect the fl ue and make all connections according to
the instructions in the Venting section.
3) Install the Surround and Hearth Trim.
Attach the Cabinet to the Framing
Slide the cabinet into the frame constructed previously and
secure with nails or sheet rock screws, installing a fastener
into at least every other hole.
Warning: Combustible materials must not extend inside
the stand-offs on the side, top and rear sup
ports. For safety reasons do not modify or
alter any components of the Kit.
51-7/8"
(1318mm)
52-3/4"
(1340mm)
Any non-combustible facing materials (such as ceramic tile
or masonry face brick) up to 1-1/2" (38mm) thick may be
used to fi nish the area inside the 1/2" (13mm) lip on the face
panels. Non-combustible tile backer board such as Wonder
board or Durock , or metal lath or screen may be fastened
directly to the front of the face panels to provide a base for
attaching facing materials if needed.
If a combustible mantel is desired, it must be above the 1/2"
(13mm) lip on the Top Face panel. This includes both the
mantel itself and any trim below the mantel. A completely
non-combustible mantel, such as stone, may be placed
wherever desired.
fire-parts.com
Tabla de contenidos
Otros manuales de Accesorios para chimeneas de Regency Fireplace Products

Regency Fireplace Products
Regency Fireplace Products VF18V-NG Manual de instrucciones

Regency Fireplace Products
Regency Fireplace Products SIT WiFi Guide Manual de usuario

Regency Fireplace Products
Regency Fireplace Products Masport 410 905 Guía de inicio rápido

Regency Fireplace Products
Regency Fireplace Products 666-945 Manual de usuario
Manuales populares de Accesorios para chimeneas de otras marcas

Bronpi
Bronpi KIT-1 Manual de usuario

Town & Country Fireplaces
Town & Country Fireplaces 22150051 Manual de usuario

Travis Industries
Travis Industries 33 DVI Manual de usuario

Superior
Superior ASD3628-TI Manual de usuario

pleasant hearth
pleasant hearth OFP28WG Manual de usuario

IHP
IHP Astria Series Manual de usuario