Redarc R-12-350S Manual de usuario

Pure Sine Wave Inverters
R-12-350S/R-24-350S
R-12-700S/R-24-700S
R-12-1000S/R-24-1000S
R-12-1500S/R-24-1500S
R-12-2000S/R-24-2000S
R-12-3000S/R-24-3000S

REDARC PURE SINE INVERTERS
REDARC Pure Sine Wave Inverters produce a pure sine wave output. This means that the power
output from a REDARC Pure Sine Wave Inverter is not only the same as the mains supply... it’s
often better!
WARNING & SAFETY INSTRUCTIONS
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they are supervised
or have been instructed on how to use the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Do NOT disassemble the (Product) - the internal circuitry contains hazardous voltages. Attempting
to service the unit yourself may result in electric shock or fire and will void the unit warranty.
Do not expose the inverter to rain, snow, spray, bilge or dust. To reduce the risk of hazard, do
not cover or obstruct the ventilation openings. Do not install the inverter in a zero-clearance
compartment. Overheating may result.
To avoid a risk of fire and/or electronic shock, make sure that existing wiring is in good condition
and not undersized.Do not operate the inverter with damaged or substandard wiring.
Some components in the inverter can cause arcs and sparks. To prevent fire or explosion, do
not put batteries, flammable materials, or anything that should be ignition–protected around the
inverter.
If battery acid contacts skin or clothing, you must wash it out with soap and water immediately.
If battery acid contacts your eyes, you must wash it out with cold running water for at least 20
minutes and get medical attention immediately.
Never smoke or make a spark or flame in the vicinity of the battery or the engine.
Do not drop a metal tool on the battery. The resulting spark or short-circuit on the battery or
other electrical part may cause an explosion.
Remove personal metal items such as rings, bracelets, necklaces, and watches when operating
with a lead-acid batteries.
Failure to do so may cause short circuit and very high temperature, which can melt metal items
and burn your skin.
1
SAL.FOR.Instruction Manual.Pure Sine Inverters – DOC435 – Version 1

CONTENTS
Table of Contents Page
Warnings and Safety Instructions 01
Contents 02
1 Introduction 03
1. 12V Specifications 03
2. 24V Specifications 04
3. Dimensions 05
2 USER Guide 06
1. Front Panel Operation 06
1. Front Panel View 06
2. On/Off/Remote Switch (700W - 3000W) 07
3. Input Level LED Display (700W - 3000W) 07
4. Load Level Display (700W - 3000W) 07
5. Status LED Displayc (All Models) 08
6. Power Saving Mode Settings (700W - 3000W) 08
7. AC Frequency Setting (All Models) 09
2. Rear Panel Operations 09
1. Rear Panel View 09
2. On/Off/Remote Switch (350W Only) 10
3. Remote Port (700W - 3000W) 10
4. Ventilation Fan 10
5. DC Input Terminal (All Models) 11
6. Chassis Ground 11
3 INSTALLATION Guide 12
1. Mounting 12
2. DC Wiring Connections (700W - 3000W) 12
1. DC Cable Size 13
3. Wiring Diagrams 14
4. DC Cable Connection (700W - 3000W) 15
1. 700W - 1500W DC Connection method 15
2. 2000W - 3000W DC Connection method 15
5. AC Safety Grounding 16
6. Inverter First Operation 16
7. Maintenance 16
4 Troubleshooting 17
5 Two Year Warranty 18
2

1 INTRODUCTION
1.1 12V Specifications
Specification R-12-350S R-12-700S R-12-1000S R-12-1500S R-12-2000S R-12-3000S
Output Power (Cont.) 350W 700W 1000W 1500W 2000W 3000W
Output Power (Max.) 385W 770W 1100W 1650W 2200W 3300W
Surge Rating (Max.) 700W 1400W 2000W 3000W 4000W 6000W
Input Voltage (Nom.) 12V 12V 12V 12V 12V 12V
Input Voltage (Min.) 10.5V 10.5V 10.5V 10.5V 10.5V 10.5V
Input Voltage (Max.) 15V 15V 15V 15V 15V 15V
Output Voltage 220/ 230/ 240V AC ± 3%
Frequency 50 / 60Hz ± 0.05%
Output Waveform Pure Sine Wave (THD < 3%)
Efficiency (full load) 91.0% 91.0% 91.0% 90.0% 91.0% 90.0%
No Load Current Draw 1.20A 1.25A 1.40A 2.64A 2.80A
Stand-By Current Draw 0.25A 0.25A 0.28A 0.60A 0.55A
Input Voltage Regulation 10.5V - 15.0V
Input Level Indicator N/A Red/ Orange/ Green LEDs
Load Level Indicator N/A Red/ Orange/ Green LEDs
Failure Indicator Red LED
Protection Overload, Short Circuit, Reverse Polarity (Fuse), Over/Under Voltage, Over Temp.
Remote Control Unit Hardwire CR-6 12 / CR-8
Safety Certificate EN60950-1
EMC EN55022:1997, EN55024: 1997, EN61000-3-2: 1998, EN61000-3-3: 1995
Operating Temp. 0 - 40°C
Cooling Loading Controlled Cooling Fan
Protection Features for 12V Inverters
Over Voltage Shutdown 15.3V
Over Voltage Restart 14.3V
Under Voltage Alarm 11.0V
Under Voltage Shutdown 10.2V
Under Voltage Restart 12.7V
Over Temperature Shutdown (Interior) 70°C
Over Temperature Restart (Interior) 45°C
Over Temperature Shutdown (Heat Sink) 90°C
Over Temperature Restart (Heat Sink) 60°C
3

1 INTRODUCTION
1.2 24V Specifications
Specification R-24-350S R-24-700S R-24-1000S R-24-1500S R-24-2000S R-24-3000S
Output Power (Cont.) 350W 700W 1000W 1500W 2000W 3000W
Output Power (Max.) 385W 770W 1100W 1650W 2200W 3300W
Surge Rating (Max.) 700W 1400W 2000W 3000W 4000W 6000W
Input Voltage (Nom.) 24V 24V 24V 24V 24V 24V
Input Voltage (Min.) 21.0V 21.0V 21.0V 21.0V 21.0V 21.0V
Input Voltage (Max.) 30V 30V 30V 30V 30V 30V
Output Voltage 220/ 230/ 240V AC ± 3%
Frequency 50 / 60Hz ± 0.05%
Output Waveform Pure Sine Wave (THD < 3%)
Efficiency (full load) 93.0% 93.0% 94.0% 93.0% 94.0% 93.0%
No Load Current Draw 0.60A 0.65A 0.70A 1.32A 1.50A
Stand-By Current Draw 0.15A 0.15A 0.15A 0.25A 0.35A
Input Voltage Regulation 21.0 - 30.0V
Input Level Indicator N/A Red/ Orange/ Green LEDs
Load Level Indicator N/A Red/ Orange/ Green LEDs
Failure Indicator Red LED
Protection Overload, Short Circuit, Reverse Polarity (Fuse), Over/Under Voltage, Over Temp.
Remote Control Unit Hardwire CR-6 24 / CR-8
Safety Certificate EN60950-1
EMC EN55022:1997, EN55024: 1997, EN61000-3-2: 1998, EN61000-3-3: 1995
Operating Temp. 0 - 40°C
Cooling Loading Controlled Cooling Fan
Protection Features for 24V Inverters
Over Voltage Shutdown 30.6V
Over Voltage Restart 28.8V
Under Voltage Alarm 22.0V
Under Voltage Shutdown 20.3V
Under Voltage Restart 25.2V
Over Temperature Shutdown (Interior) 70°C
Over Temperature Restart (Interior) 45°C
Over Temperature Shutdown (Heat Sink) 90°C
Over Temperature Restart (Heat Sink) 60°C
4

5
1 INTRODUCTION
1.3 Dimensions
Dimension 350S 700S 1000S 1500S 2000S 3000S
A180mm 270mm 340mm 370mm 370mm 400mm
B125mm 150mm 150mm 160mm 180mm 180mm
C60mm 70mm 85mm 85mm 165mm 165mm
D145mm 175mm 180mm 190mm 210mm 210mm
E132mm 195mm 195mm 195mm 245mm 245mm
F135mm 160mm 165mm 175mm 195mm 195mm
G6mm 8mm 8mm 8mm 9mm 9mm
A
B
C
D
F
E
G

6
2 USER GUIDE
The Redarc pure sine wave power inverter series is one of the most advanced mobile AC power
systems available.
For ideal operation of the power inverter, it must be installed and used properly. Please read
this instruction manual before you install and operate your inverter.
2.1 Front Panel Operation
2.1.1 Front Panel View
350W
1000W
1500W
700W
2000W
3000W
On/Off/Rem.
Switch
AC Output
Input Level
Load Level
Status
Frequency
Power Saving
AC Output
Power
Status
Frequency
On/Off/Rem.
Switch
Input Level
Load Level
Status
Frequency
Power Saving
AC Output

7
2 USER GUIDE
2.1.2 On/Off/Remote Switch (700W - 3000W)
This switch acts as an On - Off switch and can also set the unit to remote mode allowing the On
- Off functionality to be performed by either the CR-6 or CR-8 remote control.
Usage:
a. Before installing the inverter, you need to ensure the main switch is set to “OFF”.
b. Before using the remote unit, you need to ensure the main switch is set to “REMOTE”.
2.1.3 Input Level LED Display (700W - 3000W)
The Input Level LED Display is designed to advise the user of the DC Input Voltage Level. The
Input Level LED will display the Input Voltage Level using this sequence of flashes and colours
on the LED.
LED Status 12V Inverters 24V Inverters
RED Slow Blink 10.3 - 10.6 20.5 - 21.2
RED 10.6 - 11.0 21.2 - 21.8
ORANGE 11.0 - 12.1 21.8 - 24.1
GREEN 12.1 - 14.2 24.1 - 28.6
ORANGE Blink 14.2 - 15.0 28.6 - 30.0
RED Blink > 15.0 > 30.3
2.1.4 Load Level Display (700W - 3000W)
The Load Level LED Display is designed to advise the user of the currently supplied AC Wattage.
The Load Level LED will display the Loaded Wattage using this sequence of flashes and colours
on the LED.
LED Status 700W 1000W 1500W 2000W 3000W
DARK 0-56W 0-80W 0-120W 0-160W 0-240W
GREEN 56-230W 80-330W 120-495W 160-660W 240-990W
ORANGE 230-525W 330-750W 495-1125W 660-1500W 990-2250W
RED 525-672W 750-960W 1125-1450W 1500-1920W 2250-2880W
RED Blink > 672W > 960W > 1450W > 1920W > 2880W

2 USER GUIDE
2.1.5 Status LED Display (All Models)
The Status LED will display Power and Fault Status for the inverter using this sequence of
flashes and colours on the LED.
GREEN LED LED Signal Status
Solid Power OK
Slow Blink Power Saving**
RED LED LED Signal Status
Fast Blink OVP*
Slow Blink UVP*
Intermittent Blink OTP*
Solid OLP*
*Note: Refer to Troubleshooting (Section 4) for details on status indication.
**Note: Power Saving Mode not available for 350W model.
2.1.6 Power Saving Mode Settings (700W - 3000W)
Power saving mode will trigger when the AC Loaded Wattage (Power Consumption) falls below
the set threshold. The threshold can be set using S1, S2 and S3 on the DIP switch Panel in the
sequences shown on this table.
700W 1000W
1500W
2000W
3000W S1 S2 S3
DISABLE DISABLE DISABLE Off Off Off
15W 20W 40W On Off Off
25W 40W 80W Off On Off
40W 55W 125W On On Off
50W 75W 170W Off Off On
65W 95W 210W On Off On
75W 115W 245W Off On On
85W 135W 280W On On On
8

9
2 USER GUIDE
2.1.7 AC Frequency Setting (All Models)
This switch will set the output AC Frequency to either 50Hz or 60Hz. For 700W to 3000W
models S4 on the DIP switch is the AC Frequency setting.
Frequency Switch
50Hz Off
60Hz On
2.2 Rear Panel Operations
2.2.1 Rear Panel View
350W
1000W
1500W
700W
2000W
3000W
Chassis
Ground
Remote
Port
On/Off/Rem.
Switch DC Input
Terminal
Ventilation
Fan
DC Input
Terminal
Ventilation
Fan
Chassis
Ground
Remote
Port
DC Input
Terminal
Ventilation
Fan
Chassis
Ground
Remote
Port
Este manual sirve para los siguientes modelos
11
Tabla de contenidos
Otros manuales de Inversor de Redarc