RCP ADF-B38A Manual de usuario

Non-contact
Thermometer
Model # ADF-B38A

Non-Contact Thermometer
V1.1 REMOTE CARE PARTNERS PAGE 2
TABLE OF CONTENTS
INTRODUCTION ............................................................... 3
NOTES ON SAFETY ........................................................... 4
Handling batteries properly ....................................... 4
QUICK START.................................................................... 5
FEATURES ......................................................................... 7
HOW IT WORKS................................................................ 7
PRODUCT OVERVIEW...................................................... 8
SETTINGS .......................................................................... 9
TAKING A MEASUREMENT............................................. 10
Notes on Taking A Measurement ............................ 11
MEMORY FUNCTION ..................................................... 11
REPLACING THE BATTERIES............................................ 12
CLEANING ..................................................................... 13
DISPLAY MESSAGES....................................................... 14
TECHNICAL SPECIFICATION.......................................... 15
CONTACT INFORMATION AND NOTICES..................... 16
FCC Compliance Statement ................................... 16

Non-Contact Thermometer
V1.1 REMOTE CARE PARTNERS PAGE 3
Model # ADF-B38A
INSTRUCTION MANUAL
INTRODUCTION
This Non-Contact Thermometer is provided to by
Remote Care Partners (RCP), for use exclusively
with the health monitoring program from your
provider.
Please read this manual carefully and keep it
handy for future reference.

Non-Contact Thermometer
V1.1 REMOTE CARE PARTNERS PAGE 4
NOTES ON SAFETY
Please read this section carefully to familiarize
yourself with the features and operations before
using the unit.
1. Do not drop the unit.
2. Do not immerse the unit in water.
3. Keep the unit out of reach of children.
4. Avoid touching the lens with your fingers.
5. Do not use in areas with strong
electromagnetic interference.
6. Consult your physician if the reading is out
of the normal body temperature range.
7. Remove the batteries from the
thermometer if the unit will not be used for an
extended period. This will prevent battery
leakage causing damage to the thermometer.
8. If the unit is not working properly, please
contact customer service.
9. Do not disassemble the unit, Open the
battery cover only when replacing batteries.
Handling batteries properly
As soon as old batteries run out, replace them
with new batteries.
•Do not use old and new batteries together.
•Align the polarities of batteries correctly.
•When the unit will not be used for more than 3
months, remove the batteries. Otherwise,
batteries may leak and cause damage to the
unit.

Non-Contact Thermometer
V1.1 REMOTE CARE PARTNERS PAGE 5
NOTES FOR USING THIS THERMOMETER
•Always make sure the thermometer is in BODY
mode before taking a measurement. The light
next to the word BODY should be lit to indicate
it is in BODY MODE. If the light next to the word
SURFACE is lit, press the "MODE" button to
select BODY MODE.
•Store the thermometer in the room where you
take your measurements. If you move the
thermometer to a new room to take a
measurement and the temperature in the new
room is very different from where the
thermometer was stored, the reading may not
be accurate. Bring the patient to the
thermometer, don’t bring the thermometer to
the patient.
•Do not allow other people to use your
thermometer. The thermometer is
specifically assigned to you and you only.
Allowing other people to use your
thermometer can mislead your provider.

Non-Contact Thermometer
V1.1 REMOTE CARE PARTNERS PAGE 6
QUICK START
1. Press and hold "Power/Measure” trigger to turn
on the thermometer.
2. The light next to the word BODY should be lit to
indicate it is in BODY MODE. If the light next to
the word SURFACE is lit, press the "MODE"
button to select BODY MODE
3. Point the head of the thermometer .5 inches to
approximately 2 inches from the forehead
4. Pull the “Power/Measure” trigger and release.
The temperature will display in the LCD Viewing
window.
5. The thermometer will turn off automatically in 1
minute.
6. The reading will automatically be transferred to
the RCP SmartHub and then sent to your
provider.

Non-Contact Thermometer
V1.1 REMOTE CARE PARTNERS PAGE 7
FEATURES
1. Measurement range:
Body: 90°~108°F / 32°~42.2°C
Surface: 50°~140°F / 10°~60°C
2. Free to set alarm temperature.
3. Non-contact measurement avoids cross-
infection.
4. Memory for 50 readings.
5. Auto power off.
6. Unit of Measure: °F/°C.
7. Backlight.
HOW IT WORKS
Using infrared technology, the body and surface
temperature is measured.

Non-Contact Thermometer
V1.1 REMOTE CARE PARTNERS PAGE 8
PRODUCT OVERVIEW

Non-Contact Thermometer
V1.1 REMOTE CARE PARTNERS PAGE 9
SETTINGS
1. Turn on the thermometer by pressing the
“SET” Key for 4 seconds to enter the set-up
mode. The LCD viewing window will display:
F-00 and alarm temperature value. Modify
the alarm temperature by pressing the
“MODE” or “MEM” keys.
2. Press the “SET” key again and the LCD
viewing window will display F-01. Modify the
alarm parameters by using the "MODE" or
"MEM" keys.
3. Press the “SET” key again and the LCD
viewing window will display F-02. Modify the
Temperature Unit (C/F) by pressing the
“MODE” key.
4. Press the “SET” key again and the LCD
viewing window will display F-03. Modify the
temperature reading saved (Yes/No) by
pressing the “MODE” key.
5. To exit the set-up mode, press and hold the
“SET” key for 4 seconds.

Non-Contact Thermometer
V1.1 REMOTE CARE PARTNERS PAGE 10
Do not allow other people to use your thermometer.
The thermometer is specifically assigned to you and
you only. Allowing other people to use your
thermometer can mislead your provider.
TAKING A MEASUREMENT
1. Press and hold "Power/Measure” trigger to turn
on the thermometer.
2. The light next to the word BODY should be lit to
indicate it is in BODY MODE. If the light next to
the word SURFACE is lit, press the "MODE"
button to select BODY MODE
3. Point the head of the thermometer .5 inches to
approximately 2 inches from the forehead
4. Pull the “Power/Measure” trigger and release.
The temperature will display in the LCD Viewing
window.
5. The thermometer will turn off automatically in 1
minute.
6. The reading will automatically be transferred to
the RCP SmartHub and then sent to your
provider.