3
ENGLISH
Before connecting and using this product, please read this instruction
manual carefully and keep it on hand for future reference.The manual is
to be considered an integral part of this product and must accompany
it when it changes ownership as a reference for correct installation and
use as well as for the safety precautions. RCF S.p.A. will not assume any
responsibility for the incorrect installation and / or use of this product.
WARNING: To prevent the risk of fire or electric shock, never expose
this product to rain or humidity.
1. SAFETY PRECAUTIONS
All the precautions, in particular the safety ones, must be read with
special attention, as they provide important information.
2. POWER SUPPLY FROM MAINS (direct connection)
a. The mains voltage is sufficiently high to involve a risk of electrocution;
therefore, never install or connect this product when its power cable
is plugged in.
b. Before powering up, make sure that all the connections have been
made correctly and the voltage of your mains corresponds to the
voltage shown on the rating plate on the unit, if not, please contact
your RCF dealer.
c. The metallic parts of the unit are earthed by means of the power
cable.
d. Protect the power cable from damage.
e. To prevent the risk of electric shock, never open the product: there
are no parts inside that the user needs to access.
3. Make sure that no objects or liquids can get into this product, as
this may cause a short circuit. This apparatus shall not be exposed to
dripping or splashing. No objects filled with liquid, such as vases, shall
be placed on this apparatus. No naked sources (such as lighted candles)
should be placed on this apparatus.
4. Never attempt to carry out any operations, modifications or repairs
that are not expressly described in this manual. Contact your authorized
service centre or qualified personnel should any of the following
occur:
- The product does not function (or functions in an anomalous way).
- The power supply cable has been damaged.
- Objects or liquids have got in the unit.
- The product has been subject to a heavy impact.
SAFETY
PRECAUTIONS
WARNING
IMPORTANT NOTES

4
ENGLISH
5. If this product is not used for a long period, disconnect the power
cable.
6. If this product begins emitting any strange odours or smoke, switch it
off immediately and disconnect the power supply cable.
7. Do not connect this product to any equipment or accessories not
foreseen. For suspended installation, only use the dedicated anchoring
points and do not try to hang this product by using elements that are
unsuitable or not specific for this purpose.Also check the suitability of the
support surface to which the product is anchored (wall,ceiling, structure,
etc.), and the components used for attachment (screw anchors, screws,
brackets not supplied by RCF etc.), which must guarantee the security
of the system / installation over time, also considering, for example, the
mechanical vibrations normally generated by transducers.To prevent the
risk of falling equipment, do not stack multiple units of this product
unless this possibility is specified in the user manual.
8. RCF S.p.A. strongly recommends this product is only installed
by professional qualified installers (or specialised firms) who
can ensure correct installation and certify it according to the
regulations in force.The entire audio system must comply with
the current standards and regulations regarding electrical
systems.
9. Supports and trolleys
The equipment should be only used on trolleys or supports, where
necessary, that are recommended by the manufacturer. The equipment
/ support / trolley assembly must be moved with extreme caution.
Sudden stops, excessive pushing force and uneven floors may cause the
assembly to overturn.
10. There are numerous mechanical and electrical factors to be
considered when installing a professional audio system (in addition
to those which are strictly acoustic, such as sound pressure, angles of
coverage, frequency response, etc.).
11. Hearing loss
Exposure to high sound levels can cause permanent hearing loss. The
acoustic pressure level that leads to hearing loss is different from
person to person and depends on the duration of exposure. To prevent
potentially dangerous exposure to high levels of acoustic pressure,
anyone who is exposed to these levels should use adequate protection
devices. When a transducer capable of producing high sound levels is
being used, it is therefore necessary to wear ear plugs or protective
earphones. See the technical specifications in loudspeaker instruction
manuals to know their maximum sound pressure levels.

5
ENGLISH
IMPORTANT NOTES
To prevent the occurrence of noise on microphone / line signal cables,
use screened cables only and avoid putting them close to:
- Equipment that produces high-intensity electromagnetic fields (for
example, high power transformers).
- Mains cables.
- Loudspeaker lines.
OPERATING PRECAUTIONS
- Never force the control elements (keys, knobs, etc. ).
- Do not use solvents, alcohol,benzene or other volatile substances for
cleaning the external parts of this product.
OPERATING PRECAUTIONS
IMPORTANT NOTES

6
ENGLISH
RDNET CONTROL 2 is an hardware interface to connect RCF RDNET
compatible devices to a Personal Computer (PC) by means of an USB
connection.
The RDNET system was purposely developed to create a data network
for monitoring and command of more systems. The RDNET CONTROL 2
unit can manage up to 2 subnets. Up to 32 devices can be connected
to each subnet (2 subnets x 32 = total 64 devices).
The addressing of the various devices is handled automatically by
RDNET CONTROL 2 interface. Each device is assigned a unique address
during the power on procedure of network.
For the RDNET network operating, it is necessary to install the
appropriate Software on PC, on Microsoft Windows® environment.
From PC it is possible to check the operating of each single device
connected to the network and edit its parameters output level, mute,
equalization, delay, etc.
The network and devices configuration can be saved as file in the PC
and later reloaded. RDNET is a “real-time” system: Information relating
to the functioning of the devices is acquired in real-time, a feature that
allows a global view of connected devices.
For the correct working of USB (1.1 o 2.0) communication between
PC and RDNET CONTROL2 it is recommended to use the USB cable
supplied.
PRODUCT
INFORMATIONS
RCF S.P.A. THANKS YOU FOR PURCHASING THIS PRODUCT,
WHICH HAS BEEN DESIGNED TO GUARANTEE RELIABILITY AND
HIGH PERFORMANCES

7
ENGLISH
CONTROLS
AND FUNCTIONS
CH1 INDICATOR LIGHT
This indicator light, green LED,flashes to indicate data transmission
or reception in the subnet 1.
CH2 INDICATOR LIGHT
This indicator light, green LED, flashes to indicate data transmission
or reception in the subnet 2.
LINK INDICATOR LIGHT
This indicator light, green LED,will be used for future applications.
ERROR INDICATOR LIGHT
This indicator light, red LED, lights up to indicate errors during data
transmission or reception.
ON INDICATOR LIGHT
This indicator light, green LED, lights up to indicate that device is
on and powered by USB.
USB CONNECTOR
USB type B connector, for computer link, by means of cable
provided. The RDNET CONTROL 2 is powered by USB connector.
5
6
1
2
3
4
15 623 4

8
ENGLISH
RJ45 CONNECTOR CH1
Connector for Subnet 1 RDNET connection by means of CATS cable.
For connections refer to “CHANNEL CONNECTIONS” paragraph.
If this connector is used DO NOT CONNECT the connector CH1
XLR socket .
XLR CONNECTOR CH1
Connector for Subnet 1 RDNET connection.
For connections refer to “CHANNEL CONNECTIONS” paragraph.
If this connector is used DO NOT CONNECT the connector CH1
RJ45 socket .
RJ45 CONNECTOR CH2
Connector for Subnet 2 RDNET connection by means of CATS cable.
For connections refer to “CHANNELCONNECTION” paragraph.
lf this connector is used DO NOT CONNECT the connector CH2
XLR socket .
XLR CONNECTOR CH2
Connector for Subnet 2 RDNET connection. For connections refer
to “CHANNELCONNECTION” paragraph.
If this connector is used DO NOT CONNECT the connector CH2
RJ45 socket .
8
8
9
9
10
10
7
7
7 8 9 10

9
ENGLISH
CHANNEL
CONNECTION
DO NOT CONNECT BOTH RJ 45 AND XLR CONNECTORS
TO THE SAME RDNET PORT!
RJ 45 CONNECTOR
Pin
1. Available for other functions (for example: audio signal +, hot)
2. Available for other functions (for example: audio signal -, cold)
3. Available for other functions (for example: analogue ground)
4. Digital ground
5. Digital ground
6. Available for other functions (for example: power supply)
7. RS 485 A
8. RS 485 B
XLR SOCKET
Pin
1. Digital ground
2. RS 485 A
3. RS 485 B
Each of the 2 available RDNET ports of the RDNET CONTROL
2 unit can be connected to max 32 compatible devices (linked
in “daisy-chain”).
Example: the RDNET CONTROL 2 port 1 is connected to the DATA IN
input of a TTL55-A loudspeaker, of which DATA LINK parallel output is
linked to the input of the following TTL55-A loudspeaker.
In the example above, [n] is a number from 3 to 32 (max. quantity of
devices that can be connected to a subnet).The total CAT 5 cable length
of a subnet cannot exceed 900 metres (c. 2950 feet).
SUBNET
CONNECTION
TTL55-A [1] TTL55-A [2] TTL55-A [n]
DATA IN DATA IN DATA INDATA LINK DATA LINK DATA LINK
CH 1
ACTIVE
LINK
ACTIVE
LINK
ACTIVE
LINK
RDNET
CONTROL 2

10
ENGLISH
The RDNET software is protected by international copyright laws and is
to be used to configure the RCF RDNET system only.
lt is not allowed to modify or change or try to decompile this software.
In no event shall RCF be liable to end-users for any damage whatsoever,
including but not limited to financial damages for loss of business profits
or business information due to the software use or inability to use this
product. The foregoing provision is effective even if RCF has been
advised of the possibility of such damages. Even if the software has any
material, verifiable and reproducible program errors, RCF shall have no
obligation to modify such errors.
NOTES ABOUT THE
RDNET SOFTWARE
RDNET SOFTWARE
INSTALLATION
Minimum requirement: a PC with Microsoft Windows® XP,
Vista or 7 operating system, having an available USB port.
Before installing a new software release, it is necessary to remove
the previous version (if installed) by running Start > Programs > RCF
Group > RDNet > Uninstall and disconnect the USB cable between the
computer and the RDNET CONTROL 2 unit.
If “.NET Framework 4.0” has been previously
installed, the RDNET ware wizard starts.
Click the NEXT> button to proceed.
If the installed PC software does not include the
release 4.0 of MS “.NET Framework” (necessary
to install the RDNET software), it will be show the
request for downloading from the web (for free).
Run setup.exe (inside the ‘setup folder)
to start the software installation.
If internet is available, click the YES button to open
the web page where it is possible to download the
last release of “.NET Framework” software, then
install it.

11
ENGLISH
NOTES ABOUT THE
RDNET SOFTWARE
RDNET SOFTWARE
INSTALLATION
Read the license agreement.
Click “I Agree” to accept and proceed
with the software installation.
Click the NEXT > button to proceed.
lt is now possible to change the installation
folder (directory) of the RDNET software (or
keep the default path).
Choose if the software can be used by
“Everyone” or “Just me”.
Click the NEXT> button to proceed.
The wizard reminds you that it is necessary
to disconnect the USB cable between the
computer and the RDNET CONTROL 2 unit in
order to install A drivers properly.
Check if the USB cable is actually disconnected
before proceeding.
Tabla de contenidos
Otros manuales de Unidad de control de RCF
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards
BOC Edwards Q Series Manual de usuario