PURIKOR PKVSF26D Manual de usuario

PKVSF26D
Series Valve Operation Manual


Table of Contents
Introduction ..................................................................................................................................................................... 1
Main Functions ................................................................................................................................................................ 1
Specifications ..................................................................................................................................................................
2
Programming .................................................................................................................................................................... 2
1. Key Definition ........................................................................................................................................................ 2
2. Setting Methods .................................................................................................................................................... 3
3. Inquiry Function ..................................................................................................................................................... 3
4. System Initialization
...............................................................................................................................................
3
5. Menu Diagram at Different Regeneration Modes
................................................................................................ 5
6. Default Settings ..................................................................................................................................................... 7
Manual Regeneration
..................................................................................................................................................... 7
Water Hardness Adjustment (Optional for Softener Valve)
............................................................................................... 8
Optional Parts
................................................................................................................................................................. 8
1. Inlet/Outlet Screw Standards
................................................................................................................................ 8
I.
II.
III.
IV.
V.
VI.
VII.
2. Inlet/Outlet Screw Adaptor (Optional)
.................................................................................................................. 8
VIII.
IX.
X.
XI.
XII.
3. Inlet/Outlet Connections Types
.......................
................................
...................................................................... 9
4. Drain Line Flow Controls (DLFC) and Injector
......................................................................................................... 9
5. Bypass Assembly
................................................................................................................................................. 10
Valve Powerhead Assembly
...........................................................................................................................................
11
Valve Body Assembly
..................................................................................................................................................... 14
Bypass Assembly
........................................................................................................................................................... 17
General Valve Installation
............................................................................................................................................. 19
Trouble Shooting ............................................................................................................................................................ 20
XIII.
Warranty ........................................................................................................................................................................
21

1
I. Introduction
This valve is controlled with simple, user-friendly electronics displayed on a LCD screen. The main page displays the
current time. In addition, the main page also shows key valve information including: regeneration mode, volume
remaining (meter mode), regeneration days remaining (timer mode).
II. Main Functions
• Valve Operation Mode:
1. SOFTENER: Standard water softener operation.
2. FILTER: Automatic backwashing filters such as Multi-Media Depth or Carbon Filter.
• Regeneration Mode:
1. TIMER 2. METER IMMEDIATE 3. METER DELAYED 4. MIX REGENERATION
• Water Hardness can be adjusted:
User can adjust the mixing valve to get proper water hardness (optional for softener valve).
• Display Format:
Metric format and US format are available to meet the different customers’ requirements.
• Three factory setting defaults are available:
1. Large capacity mode (ab. L.CAPA.).........fit the large size tank.
2. Medium capacity mode (ab. M.CAPA.)......fit the medium size tank.
3. Small capacity mode (ab. S.CAPA.).........fit the small size tank.
• Auto-locking:
All keys will be locked after 3 minutes during the stand-by status, press and hold “MENU” key for 3 seconds to
unlock.
PKVSF26D Series Valve Operation Manual
PKVSF26D Key PadPKVSF26D Series Outline
9:00 AM
F0900G
MENU
SET/REGEN DOWN/-
UP/+

1. Key Definition:
Menu key “ ”:
• Press this key to enter or exit the menu.
• Press and hold this key for 3 seconds to unlock when the screen was locked at standby status.
Set/Regen. key “ ”:
• Press this key to select a program or to save the settings.
• Press and hold the key for 3 seconds to initiate a manual regeneration at standby status.
UpandDownkey “ ”, “ ”:
• Press the key to increase or decrease the value of the settings Press the key to enter the previous or the next menu.
PKVSF26D Series Valve Operation Manual
2
III. Specifications
• Hydrostatic Test Pressure ............. 350 psi (24.15 bar)
• Working Pressure ........................ 20~125 psi (1.38~8.62 bar)
• Working Temperature ................... 1ºC~39ºC
• Riser Pipe Diameter Required ........ 1.050 inch (26.7mm)
• Electrical Adapter ........................ Input: AC110V/AC240V, 50Hz/60Hz; Output: AC12V
• Pressure Tank Thread ................... 2.5”NPSM
• Inlet/Outlet Connector ...................1”, 3/4”, 1/2”(PPR, PPO, Brass)
IV. Programming
PKVSF26D Series Dimensional Drawing (unit: inch, mm in brackets)

2. Setting Methods:
• Press the key “ ” to enter the menu.
• Press the key “ ” or “ ” to select a parameter.
• Press the key “ ” the parameter starts flashing
• Pressthekey “ ” or “ ”to change the value.
• Press the key “ ” to save the setting
• Press the key “ ” or “ ” to select another parameter.
• Follow the above steps to change another parameter.
• Press the key “ ” to exit settings.
Program will be back to standby status if any key was not operated in 1 minute. Without being operated in 3 minutes,
the keys will be locked.
3. Inquiry Function:
Press the key “ ”and “ ” simultaneously at the standby status, the screen will
display different regeneration information at different regeneration mode.
• Timer:
The first raw shows the days remaining of one regeneration cycle.
The second raw shows regeneration time.
• Meter Immediate, Meter Delayed, Mix Regeneration:
The first raw is the volume remaining of one regeneration cycle in meter. “G” refers to Gallon
The second raw is total usage.
4. System Initialization:
When power is first supplied, the valve may take about two minutes to initialize,
and the valve will show:
PKVSF26D Series Valve Operation Manual
3
You can only change the flashing parameters.
D-07
02:00 AM
1300G
0000800G
WAITING
PLEASE

PKVSF26D Series Valve Operation Manual
4
09:00 AM
D-07
Current Time
Timer Regeneration
Mode
Regeneration Days Remaining
09:00 AM
F0900G
Current Time
Meter Inmediate
Regeneration Mode
Volume Remaining
Gallon
09:00 AM
D0900G
Current Time
Meter Delayed
Regeneration Mode
Volume Remaining
Gallon
09:00 AM
M0900G
Current Time
Mix Regeneration
Mode
Volume Remaining
Gallon
Any key will be overridden at this time. When the valve reaches the service position, it will display:
Regeneration Mode: Timer
Regeneration Mode: Meter Immediate
Regeneration Mode: Meter Delayed
Regeneration Mode: Mix Regeneration

PKVSF26D Series Valve Operation Manual
5
5. Menu Diagram at Different Regeneration Modes:
REGIONAL
METRIC
REGIONAL
US
METER
INMEDIATE
MO-DA-YE
09-16-09
TIME
09:00 AM
REG. CAP.
0900G
BACK WASH
20
BRINE
50
RINSE
10
REFILL
5
LOAD
DEFAULT
METER
DELAYED
MO-DA-YE
09-16-09
TIME
09:00 AM
REG. TIME
02:00 AM
REG. CAP.
0900G
BACK WASH
20
BRINE
50
RINSE
10
REFILL
5
LOAD
DEFAULT
TIMER
MO-DA-YE
09-16-09
TIME
09:00 AM
REG. TIME
02:00 AM
REG. DAYS
07
BACK WASH
20
BRINE
50
RINSE
10
REFILL
5
LOAD
DEFAULT
LOAD
L. CAPA.
LOAD
M. CAPA.
LOAD
S. CAPA.
MIX
REGEN
MO-DA-YE
09-16-09
TIME
09:00 AM
REG. TIME
02:00 AM
REG. DAYS
07
REG. CAP.
0900G
BACK WASH
20
BRINE
50
RINSE
10
REFILL
5
LOAD
DEFAULT
PRESS MENU KEY
END

PKVSF26D Series Valve Operation Manual
6
There is no “BRINE DURATION” and “REFILL DURATION” in filter valve.
2 REGIONAL
METRIC
TIMER
TIME
REG. CAP.
BACKWASH
BRINE
RINSE
REFILL
METER
IMMEDIATE
METER
DELAYED
MIX REGEN
US
(REGENERATION
MODE)
MO-DA-YE
(MONTH-DATE-YE AR)
REG. TIME
(REGENERATION TIME)
REG. DAYS
(REGENERATION DAYS)
3
4
5
6
7
9
10
11
12
13
This option controls which unit format should be displayed in
the valve display.
The unit will initiate a regeneration at the next pre-set
regeneration time based on the interval of regeneration
days.
This is the most common setting. When the volume
remaining reaches zero, the system will initiate a
regeneration at the next pre-set regeneration time.
This setting is the current date. The date is used to track the
last time the system regenerated.
This setting controls the time when a regeneration cycle will
start.
This value is the interval (days) between regenerations. It is
used to determine how many days between regenerations.
This value is the total capacity between regenerations. It is
used to determine how many gallons can be used between
regenerations.
This setting controls the length of time for the unit to clean
the bed by reversing the flow of water upwards through the
bed and out to the drain.
This setting controls the length of time for the unit to draw
regeneration (brine for softeners) from the brine tank and
slowly rinse it from the top to bottom of the media tank.
This setting controls the length of time to give the tank a final
rinse from the top to the bottom in order to remove any last
traces of the regeneration from the tank.
This setting controls the length of time which the brine valve
will open to refill the brine tank with water in order to produce
the regeneration solution for the next regeneration cycle.
The water accurately measured through the valves brine line
flow control to make a precise quantity of regeneration
solution.
This setting is the current time of day.
When the volume remaining reaches zero, the system will
initiate a regeneration at the next pre-set regeneration time.
If the days between regeneration are reached before the
volume remaining reaches zero, the system will override the
meter setting and initiate a regeneration.
The unit will initiate a regeneration immediately after the
volume remaining reaches zero.
PARAMETER OPTIONS DESCRIPTION

V. Manual Regeneration
• Press and hold the key “ ” for 3 seconds to unlock screen.
• Press and hold the key “ ” for 3 seconds to initiate a manual regeneration. Screen will display:
“BACKWASH” starts flashing. When the valve reaches “BACKWASH” position, “BACKWASH” stops flashing. Dash line (the
second raw) will be shortened on the way of regeneration. Pressing any key will automatically advance the valve to the
next cycle position: BRINE, Screen will display:
Valve will be advanced to the rest of the regeneration (RINSE and REFILL) just like the above steps.
PKVSF26D Series Valve Operation Manual
7
6. Default Settings.
Three default settings are available:
• Large capacity mode (L-CAPA.) ........... fit the larger size tank.
• Medium capacity mode (M-CAPA.) ....... fit the medium size tank.
• Small capacity mode (S-CAPA.) ......... fit the smaller size tank.
Default value as follows:
14 LOAD DEFAULT This setting allows the current settings to be erased and
changed back to the default settings.
BACKWASH DURATION (minute)
BRINE DURATION (minute)
RINSE DURATION (minute)
REFILL DURATION (minute)
REGEN. DAYS (day)
REGEN. CAPACITY (gallon)
FOR METER VALVE
15
50
10
7
8
10
35
8
5
5
6
20
5
3
3
1300 800
Large
Capacity
Medium
Capacity
Small
Capacity
2000
BACKWASH
---------------
BRINE
---------------
Tabla de contenidos
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards
BOC Edwards Q Series Manual de usuario