PTT ROIP102 Series Manual de usuario

RoIP-102 User Manual
Cross-Network Gateway
(Radio,VoIP,Public Announce)
User Manual
ROIP102 Series
Version:1.0
2011-4-9
For environmental protection,please view this manual electronically and
only print the pages you need
- RoIP-102 -

RoIP-102 User Manual
Content
I. Important Notices.............................................................................................. 3
II. Gift Box Check List......................................................................................... 4
III. Overview ........................................................................................................5
IV. Installation ......................................................................................................7
V. Default Factory Settings ................................................................................10
VI. Device Configuration Via Built-in Web Server ........................................... 11
VII. Call settings.................................................................................................14
VIII. Application Examples ...............................................................................17
IX. Hardware Specifications ..............................................................................20

RoIP-102 User Manual
I. Important Notices
i. This product is used to link up the civilian radio network,internet,and cellular phone
network.Its operation and performance rely on the broadband network connections via private
and/or public networks and the cellular phone networks.Due to the stability and reliability of these
networks,this product may not be able to link up all the networks connected without any
interruptions.Therefore,it is not recommended to use this product in an emergency system or a
communication system with zero-failure.
ii. This product can bridge and extend radio networks all over the world.Please consult your
local regulations in order to use this product legally.
iii. This product requires the use of dynamic DNS(DDNS) service.For testing purpose,this
DDNS service is temporary provided for free by Skyline Technology. How ever, this
service is not guaranteed without any interruptions.Customers are urged to build their own DDNS
server or obtain this service from a DDNS provider.Free DDNS server software may be obtained
freely from your local network service provider.
iv. Customers and/or users are taking full responsibilities and all risks in using this product.We
are not responsible for any direct or indirect losses caused by,but not limited to,communication
failures as a result of product failure or network problems.
CUSTOMERS ARE ASSUMED TO HAVE READ AND ACCEPTED WITH FULL
UNDERSTANDINGS OF THE IMPORTANT NOTICES STATED ABOVE.

RoIP-102 User Manual
II. Gift Box Check List
Upon unpacking the gift box,please check carefully that all items listed below are
included.Please report to your supplier for any missing items immediately.
1×PPT Adapter Cables
1×AC/DC Adapter
Input:110/220 VAC
Output:12VDC,2A
1×Main Unit
1×Ethernet Cable

RoIP-102 User Manual
III. Overview
The fundamental of RoIP Radio over IP technology is to convert the audio and PTT signals in
a radio terminal into IP packets and then transmit the data via the IP networks.The challenge in this
technology is to insure that the audio is transmitted in real time and the PTT control signal is
transmitted immediately and reliably.The radio range is general limited by the restricted
transmitting power,the antenna sensitivity,and other environmental factors.The success deployment
of this technology extends the coverage of a radio network without using expensive repeaters or
links up multiple radio networks in the world.In addition,this technology can also link up the radio
world to the VoIP world and the cellular world easily.It truly makes voice communications across
multiple networks possible.
RoIP 102 basic version is a more compact, more practical high-tech multiple network
(Radio,Cellular,VoIP) equipment,which access to a group,no GSM module,simply complete the
radio voice signals into IP signals,access to the Professdional Edition or Stardard Edition RoIP
302M group,to achieve the client and the central station intercom communication.Also has a remote
control switch interface,which enables remote control.
RoIP102 gateway can be installed in IP networks with intranet or internet connections via
ADSL modem,Cable modem,or Local Area Network (LAN). The unique built-in DDNS client can
help to simplify the installation and configuration without relying on a voice relay server in order to
achieve interconnections among RoIP Series gateways.
i. Basic link diagram

RoIP-102 User Manual
ii. Basic networking:multi-region over internet
The diagram above demonstrates A to use with the conference system RoIP302M as a central
switching point,the other three regions using RoIP102.Through this link,ABCD four areas to
achieve multi-region interconnections among RoIP Series gateways.
iii. Model Nomenclature

RoIP-102 User Manual
IV. Installation
i. Back Panel
Label
1
2
Name
PTT1
Reote Switch
Description
6-pin RJ11 port for PTT Adapter Cable
Relay switch with 220VAC input and 500 mA
load current.
3
3
5
WAN
LAN
Power
10/100Base-T WAN connection for external
10/100Base-T LAN connection
12V 1A
ii. LED Indicators
LED
Power
RUN
Function
Pwoer
RoIP Status
Description
Lights up when the power is connected
Flashes every 4 s indicates the device is not ready
Flashes every 2 s indicates the device is ready
LAN
PC
LAN port status
PC port status
Lights up when the LAN port is connected
Blinks when there are data transmissions.
Lights up when the PC port is connected.
Blinks when there are data transmissions.
Channel 1 is receiving / transmitting.
Channel 1
Channel 1
Tx/Rx status

RoIP-102 User Manual
iii. Channel Port Pin Assignment
The channel port is 6-pin RJ-11 Socket
1、PTTOUT 2、GND
3、Vin(RX)4、Aout(TX)
5、GND
6、PTTIN
iv. PTT Adapter Cable wiring Diagram
v. Switch Port
The built-in relay switch is connected to the middle two pins
of the RJ-11 socket.It acts as an ON/OFF switch for the
external system connected.

RoIP-102 User Manual
vi. Main Unit Setup
Connect the Channel Port to a Radio Channel via the PPT Adapter Cabel
provided.Up to 1 channel is supported.
Connect the WAN Port to a router,network switch,ADSL/Cabel Modem for access
an external network or the public network.
Connect the Switch Port to an external system fro remote control.It can be used to
switch on and off a Public Announce (PA) system to instant broadcast.If the relay
switch is connected to high voltage load.The maximum rating for the internal relay is
240VAC and 500 mA load current.
Connect the LAN Port to a local PC or a local Ethernet network(LAN).This allows
sharing the external network connected to the WAN Port with the local
network.However,the shared network is intended for configuration the device and is
best not used for high data traffics applications in order for the device to insure the
best voice quality.

RoIP-102 User Manual
V. Default Factory Settings
The table below shows the factory default settings.There are two way to reset to the factory
default settings:
i. Press the RESET switch for more than 15 seconds.
ii. In the Configuration paga,select Tools and then Reset Config.
Item
Factory Default Settings
Range
Login ID
Login Password
admin
admin
Programmable(16
characters in the ASCII
table)
WAN Port Setting
LAN Port Setting
PTT State
DHCP
192.168.8.1
“0”is active
“0” is active low
“1” is active high
PTT maximum duration
Jitter Delay
60 seconds
60 milliseconds
Less than 600 seconds
20-220 milliseconds
Tabla de contenidos
Manuales populares de Puerta de otras marcas

LST
LST M500RFE-AS Manual de usuario

Kinnex
Kinnex Media Gateway Manual de usuario

2N Telekomunikace
2N Telekomunikace 2N StarGate Manual de usuario

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manual de usuario

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manual de usuario

Telsey
Telsey CPVA 500 - SIP Manual de usuario