PROVA 1011 Manual de usuario

PROVA 1011
Solar System Analyzer
Users Manual
PROVA INSTRUMENTS INC.
This unit (excluding Remote Solar Detector 1012) passes
the following tests:
EN 61010-1: 2010
EN 61010-2-030: 2010
CAT II 1000V, CAT III 300V
Pollution Degree 2
EN61326-1: 2006 Class B
(CISPR 11: 2009/A1: 2010 Group 1 Class B,
EN 61326-1: 2006, IEC 61000-4-2: 2008,
IEC 61000-4-3: 2006+A1:2007+A2:2010,
IEC 61000-4-8: 2009)
Safety Symbols
Please read the statement thoroughly to prevent injury or
loss of life, and prevent damage to this product.
Earth (ground)
DC (Direct Current)

Conforms to relevant European Union
directives.
Do not dispose of this instrument as unsorted
municipal waste. Contact a qualified
recycler for disposal.
Caution:
1. The ventilation openings on the unit should
not be blocked.
2. Please pay attention to polarity of DC input,
follow the polarity info by the input jack.
Caution, Risk of Electric Shock.
This equipment is not for
measurements performed for CAT IV.
Please remove all the test leads
before performing maintenance,
cleaning, battery replacement, fuse
replacement, etc.
Do Not plug in the AC adapter when
the ambient temperature exceeds
45℃/ 113℉.
Do Not charge the lithium battery
when the ambient temperature
exceeds 45℃/ 113℉.
© 2013 PROVA INSTRUMENTS INC. All rights reserved.

Table of Contents
I
I. Preparation ............................................................................................1
II. Features .................................................................................................2
III. Panel Description..................................................................................4
A. Solar system analyzer................................................................4
B. Remote Solar Detector 1012 (with Thermometer).................11
IV. Operation ............................................................................................ 13
A. Connecting Diagram ............................................................... 14
B. AUTO SCAN ............................................................................. 19
C. REPORT.................................................................................... 23
D. FILE LIST.................................................................................. 25
E. REF MODULE........................................................................... 27
F. SOFTWARE KEYBOARD ........................................................ 29
G. ZERO Calibration..................................................................... 30
H. Data Logging............................................................................ 31
I. Clear Recorded (File) Data and Restore Defaults ................ 33
J. SETUP Parameters.................................................................. 34
K. THERMOMETER Setup ........................................................... 36
L. POWER Mode .......................................................................... 37
M. Irradiance/Temperature (Irr Tc) Mode .................................... 44
V. Application Notes............................................................................... 47
A. Quality Control at Production Line, Warehouse, or Site of
Installation. ....................................................................................... 47
B. Identify Requirements of Solar Power System ........................ 48
C. Maintenance of Solar Panels...................................................... 49
Table of Contents
II
D. Verify the Best Installation Angles of Solar Panels.................. 51
VI. Specifications ..................................................................................... 52
A. Electrical Specifications ......................................................... 52
B. General Specifications............................................................ 56
VII. Battery Replacement (Recharging) .................................................. 59
VIII.
Fuse Replacement.............................................................................. 62
IX. Maintenance & Cleaning.................................................................... 63

1
This Solar system analyzer and the Remote solar detector use rechargeable
lithium batteries.
The rechargeable lithium batteries are pre-installed in the solar system
analyzer and the Remote solar detector at the factory.
The Solar System Analyzer
Before using the new rechargeable lithium battery, please charge it for
10~12 hours continuously for better battery life.
Users can plug in the AC adaptor and no need to turn on the Analyzer.
Then the rechargeable lithium battery is charged automatically.
The Remote Solar Detector (RSD)
Before using the new rechargeable lithium battery, please charge it for 4
hours continuously for better battery life.
Users can connect the USB power cord with the RSD and a PC USB port,
then the rechargeable lithium battery is charged automatically.
I. Preparation
2
■ I-V curve test for solar system
■ Max. solar system power (Pmax) search by Auto-scan:
1000V, 12A (12000W capability)
■ The analyzer and the Remote Solar Detector is connected by Bluetooth
wireless communication (Bluetooth 2.1 + EDR Class 1).
■ The Remote Solar Detector is moisture-proof.
■ Intelligent test logic with no personnel attendance required in the field.
Solar system analyzer waits and tests the system until appropriate
sunlight irradiance is detected.
■ Max. voltage (Vpm) at Pmax
■ Max. current (Ipm) at Pmax
■ Voltage at open circuit (Voc)
■ Current at short circuit (Isc)
■ Efficiency (%) calculation of solar system
■ Temperature measurement of solar panels
■ Irradiance measurement of sun light
■ Series resistance (Rs) calculation of solar panels
■ I-V curve with cursor to display each data point
■ With data logging/open function, the I-V curves of solar system can be
analyzed/recorded for a period of time (e.g. 60 min.)
■ Conversion of I-V curve under OPC to data under standard test
condition (STC) based upon IEC standard
■ Provide OPerating Condition (OPC) and Standard Test Condition (STC)
test reports for verification of solar panel performance (OK, or NO OK)
■ Users can set up the parameters of solar panels
II. Features

3
■ Users can set up the series number of solar panels. Parameters of
many solar panels can be measured in one measurement.
■ The irradiances and temperatures of solar panels can be continuously
measured, monitored and recorded.
■ Built-in calendar clock
■ AC power adaptor
■ Rechargeable lithium battery, low battery warning
■ Optical USB cable for PC
■ With optional power clamps (SOLAR 15 DC Current Probe and SOLAR
21 AC Power Clamp), continuously measure/monitor/record the DC
power output of solar system and the AC power output of inverter (1
phase or balanced 3 phases); calculate the efficiency of DC to AC
power conversion and the efficiency of the max. output power
4
A. Solar system analyzer
A-1 FRONT PANEL
III. Panel Description
9
1
2
15
16
3 17
18
19
4
5
12
13
14
10
11
6
8
20
7

5
1.
STC
POWER
STC POWER button
Press this button to switch the display to STC or OPC curves;
or press it to enter POWER mode.
2.
ENTER
ENTER button
(In the FILE LIST) Press this button to open a chosen file (REC file or
Mod file).
3.
FILE
EXIT FILE EXIT button
Press this button to display File List. Press it again to exit File List.
4. DELETE button
(In the FILE LIST) Press this button to delete the data of a chosen file.
5. I/V/P
Irr / Tc I/V/P Irr/Tc button
After AUTO-SCAN, press this button to select I-V curves or P-V curves,
or display both. When under Irradiance/Temperature (Irr Tc) Mode,
press this button to select Irradiance curves or Temperature curves.
6. ZERO ZERO button
For Zero calibration and Timer reset. Connect two testing clips with
each other and press this button, the zero calibration of voltage and
current will be performed. Regular zero calibration would maintain the
accuracy of the instruments. Under POWER mode or Irr Tc mode,
press this button to reset the Timer and curve drawings.
7. SOFTWARE KEYBOARD button
6
Press this button to display or conceal the SOFTWARE KEYBOARD
which be used to type in characters.
8.
AUTO
SCAN AUTO SCAN button
Auto scan I-V curve test. Press this button for 2 sec. to perform the
auto scan of intelligent test logic.
9. LCD
LCD displays measurement data and curves.
10.
SETUP
SETUP button
Enter/Exit (parameter) SETUP menu.
11. button
(1) In a curve, press it to move the cursor left.
(2) In SETUP menu or REF MODULE function or FILE LIST, press it to
decrement value by 1 or display the file of previous page.
12. button
In “SETUP menu” or “REF MODULE function” or “File List”, press ▲
button to select the previous item or file.
13. button
In “SETUP menu” or “REF MODULE function” or “File List”, press ▼
button to select the next item or file.
14. button
(1) In a curve, press it to move the cursor right.
(2) In SETUP menu or REF MODULE function or FILE LIST, press it to

7
increment value by 1 or display the file of next page.
15.
REF
MODULE
REF MODULE button
Enter/Exit the editing function of solar panel parameters.
16.
REPORT
REPORT button
Press this button to display Standard Test Condition (STC) report and
OPerating Condition (OPC) report, or search the Remote Solar Detector
again.
17.
REC
REC button
(1) Press this button to start data logging. Press it again to stop data
logging.
(2) How to clear recorded data: keep pressing REC button and turn on
the Analyzer, then all the data recorded in the Analyzer will be
completely deleted. And the factory defaults will be restored.
18.
Irr
Tc Irr Tc button
Press this button to enter or exit Irradiance/Temperature mode.
19. ~
POWER
η
DC graph/ AC graph/ Efficiency button
Press this button to display “DC power graph” or “AC power graph” or
“Efficiency”.
20. Power button
Turn on/off the power of the Analyzer.
8
A-2 REAR PANEL
1. Communication window:
(1) Connecting the Analyzer with PC via USB cable.
(2) Or under POWER mode, connecting the Analyzer with the
communication cable of Solar 21 AC Power Clamp.
2. AC to DC adaptor input.
1 2
3
5
4
6

9
3. Terminal for connecting Solar 15 DC Current Probe
4. Stand
5. Battery cover
6. Screw of battery cover
Note:
When the Analyzer is under POWER mode, the PC
Application Software can not communicate with the
Analyzer.
10
A-3 TOP PANEL
CAT 1000V I-
V+ I+
V-
DO NOT BLOCK VENTILATION OPENINGS
CAT 300V
1000V MAX 12A MAX
1. V+ terminal
2. I+ terminal
3. V- terminal
4. I- terminal
1 2
3 4

11
B. Remote Solar Detector 1012 (with Thermometer)
Remote Solar Detector (RSD for short)
1. Box for Remote Solar Detector.
2. Auxiliary Thermometer.
2
1
12
1. Power switch of RSD
2. The hole to plug in USB power cord
USB power cord
Note: Apply Thermal conductive gel on the metal part
of Auxiliary thermometer, then stick it on solar panel
(back side) to detect the temperature of solar panel.
And Thermal conductive gel can be removed easily.
1
2

13
IV. Operation
Warning: To avoid risk of electric shock and damage
to the unit, do not touch any internal components with
tools of any kind through the ventilation opening.
Warning: AC adaptor is used for lithium battery
recharging only. The power source of the Solar
System Analyzer is always the (rechargeable) lithium
battery, NOT AC adaptor.
Warning: When using a lithium battery as the power
source, please do not plug in an AC adaptor. If users
plug in an AC adaptor during operation, power to the
analyzer will be interrupted and the data during
operation will be lost.
Note: When pressing any button, users will hear a
sound of buzzer. When keeping pressing it for more
than 2 seconds, users will hear another sound of
buzzer. This status is normal.
14
A. Connecting Diagram
Solar (DC) System
4-wire Testing Clips Connecting Diagram
Tabla de contenidos
Otros manuales de Instrumento de medición de PROVA
Manuales populares de Instrumento de medición de otras marcas

Endress+Hauser
Endress+Hauser Proline Promag 50 Especificaciones técnicas

Siemens
Siemens SITRANS F Coriolis FCT030 Manual de lista de piezas

KLINGER
KLINGER CMF V Series Manual de usuario

EXFO
EXFO FTB-2 Manual de operación y mantenimiento

Keysight
Keysight M8290A Manual de usuario

ADTEK
ADTEK MW-5 Manual de usuario