INSTALLER MENU
6 Accessing the installer menu
The installation menu is still accessible after
commissioning.
• Press the button for 7 seconds .
• Enter the installer access code 96.
7 Returning to the user menu
• Press the button for 3 seconds to
return to the main user screen.
8 Installer menu note
The installer menu customises itself depending
on the appliance it is connected to and the
connection method.
8.1 New functions
Automatic heating curve (if an outdoor sensor is
connected)
The automatic heating curve function continually
seeks the most suitable value to ensure your
comfort and the efficiency of your heating
system. The optimum value is obtained
approximately 24 hours after the system is
started. It is recommended that you activate
this function. If the function is deactivated,
the heating curve can be set manually by the
installer.
Thermostat function (if an outside sensor is
connected)
The heating system alters the water temperature
in the heating circuit depending on:
the ambient temperature,
the outside temperature.
If this function is deactivated, the heating
system no longer takes into account the ambient
temperature. The heating system uses just the
outside temperature.
Anticipation
The heating system anticipates the first
programmed setting change in the morning.
This function allows it to reach the programmed
temperature rapidly (the function is available and
independent for each zone).
Recirculation
This function requires the installation of an
option card in the boiler. The installation of a
recirculation pump allows a shorter waiting
time when drawing offhot water. The operating
ranges are programmable on the professional
menu. The programming for a day starts at 00:00
with a maximum of 7 time slots in 24 hours.
Performance index
The performance indicator is calculated from the
efficiency of all appliances over the last 24 hours.
The cursor moves along a scale graduated.
Service reminder
This function reminds the end user to service the
appliance. The user must plan the maintenance
of their system.
The date must be entered into the professional
menu during installation and after each
maintenance.
The icon « » is displayed on the room
thermostat screen 30 days before the date
entered into the installer menu.
INSTALLER MENU