CARE AND MAINTENANCE TIPS
1. Keep the inner parts of the handpiece as free as possible of dust and filing residue.
2. Use Clinilotion on a tissue to remove dust from the unit and avoid moisture inside the unit (never spray
Clinilotion directly on the device nor handpiece).
3. Only use bits that conform to the standard 2.35mm diameter size and avoid using damaged or rusty bits.
Improper use of this kind can lead to excessive wear and tear of the ball bearings. Follow ‘Professionails’
safety procedures and keep to the designated safe speed.
4. Do not subject the handpiece to hard shocks, as this can damage the bearings.
If you do drop the handpiece, check if the filing bit is not damaged or twisted.
Stay alert for signs of damages such as noise and overheating.
If the handpiece is damaged, send it for repair right away.
SAFETY INSTRUCTIONS
Before Using the unit:
1. Never set up the unit in a wet or humid environment.
2. Never bring the unit into direct contact with fire, gas, oxygen or hot objects such as cooker hot plates.
When operating the unit:
1. The handpiece must be used only with the device it is supplied with.
2. Suitable filing bits:
• Use only ProNails approved bits at the recommended minimum and maximum rotation speeds.
• Standard size: 2.35mm shaft diameter and 35 to 40 mm shaft length
• Only use balanced filing bits with rounded shaft end.
• Do not use rusty, twisted or damaged filing bits.
3. Switch o the unit before changing the rotation direction.
4. Switch o the unit before changing filing bits.
5. Take every possible precaution not to drop the handpiece or damage it in any other way.
6. Should problems with the handpiece arise, please send it for repair right away.
7. Do not wash or lubricate the handpiece.
8. Never switch on the unit when the chuck is open.
9. When storing the unit, insert the test bit into the chuck.
“This appliance is not intended for use by persons who lack experience and filing knowledge. May be used
by students under supervision of a certified ProNails educator.
WARRANTY
• 1 Year
• Warranty does not include misuse or normal wear of the bearings, carbon brush, collet chuck,
spindle and armature.
Professionails NV • Ruiterijschool 11 • B-2930 Brasschaat • Belgium • www.pronails.com • info@pronails.com