Prodys QLST Manual de usuario

Ocober 2017
Rev. 1.3
Last valid version: 2.2.2

Prodys S.L. Tel: +34 91 6896880 Fax: +34 91 6943777 Email: sales@prodys.net Web: www.prodys.com
Page 2
Index
Index 2
CE Declaration of Compliance 4
Introduction 5
I.1 QLST Features ....................................................................... 6
Installation Guide 7
II.1 Initial checks ........................................................................ 7
II.2 Setting the IP address.............................................................. 7
Front and Rear panels 9
III.1 Front Panel ......................................................................... 9
III.1.1 ON/OFF Button ................................................................ 9
III.1.2 USB Display connector ........................................................ 9
III.1.3 LEDs ............................................................................. 9
III.2 Rear Panels ........................................................................10
III.2.1 Power supply ..................................................................10
III.2.2 Audio interfaces ..............................................................10
III.2.2.1. Digital audio AES/EBU STEREO input/output 10
III.2.2.2. Analog audio input/output 11
III.2.3 Network interfaces...........................................................11
III.2.3.1. LAN1: 11
III.2.3.2. LAN2: 12
III.2.3.3. Wi-Fi on a USB modem: 13
III.2.4 Control interfaces ............................................................13
III.2.4.1. The RS232 port: 13
III.2.4.2. Rear USB slots: 14
III.3 Bottom side (Factory default switch)..........................................15
Technical Specifications 16
IV.1 Dimensions & Weight.............................................................16
IV.2 Power Supply ......................................................................16

Prodys S.L. Tel: +34 91 6896880 Fax: +34 91 6943777 Email: sales@prodys.net Web: www.prodys.com
Page 3
IV.3 User interface .....................................................................16
IV.4 Audio inputs /outputs & controls ..............................................16
IV.5 Communication ...................................................................16
IV.6 Audio Compression ...............................................................17
IV.7 Audio Storage .....................................................................17
Picture index 18

Prodys S.L. Tel: +34 91 6896880 Fax: +34 91 6943777 Email: sales@prodys.net Web: www.prodys.com
Page 4
CE Declaration of Compliance
Procesamiento Digital y Sistemas S.L., hereby declares that Quantum ST bearing
the CE168X parking are in compliance with Electromagnetic Compatibility
Directive (2004/108/EEC), and the Low Voltage Directive (2006/95/EEC) of the
European Union.
A “Declaration of conformity” for Quantum ST is available on file at Prodys offices
Your product is designed and manufactured with high quality
materials and components, which can be recycled and reused.
When this crossed-out wheeled bin symbol with black bar underneath
is attached to a product it means that product is covered by the
European Directive 2002/96/EC.
Please, inform yourself about the local separate collection system for
electrical and electronic products.
Please act according to your local rules and do not dispose of your old
products with your normal household waste. The correct disposal of
your old product will help prevent potential negative consequences for
the environment and human health.

Prodys S.L. Tel: +34 91 6896880 Fax: +34 91 6943777 Email: sales@prodys.net Web: www.prodys.com
Page 5
INTRODUCTION
Picture 1. QLST codec.
QLST is a small IP audio codec designed to be the studio counterpart of the
Quantum Lite handheld audio codec. Like the rest of the audio codec from the
Quantum family, it inherits world-class IP technology from the Prodys Quantum
Codec Family.
Its main application is to receive, decode and store (in a external memory
device) audio streams from remote Quantum Lite units. But QLST is not just a
decoder; it is also capable of encoding audio back to the remote Quantum Lite
codec.
This unit can be controlled from its built-in web graphical interface, its front
panel display (optional), or from the ProdysControlPlus application.
Chapter I

Prodys S.L. Tel: +34 91 6896880 Fax: +34 91 6943777 Email: sales@prodys.net Web: www.prodys.com
Page 6
I.1 QLST Features
Among QLST most remarkable features are:
Analog Hardware or Digital Audio Hardware: Any of two flavours might
be purchased: either analogue or AES/EBU in/out. QLST is offered with
professional XLR line level audio inputs and outputs. These can be either
analog or AES/EBU digital.
Compression algorithms 1: QLST is equipped with OPUS and apt-X
compression algorithms to guarantee low delay communications.
Communications: IP (2 Ethernet interfaces).
Control and monitoring: This unit can be controlled from its built-in web
graphical interface, its front panel display menu (with an optional touch
panel), or from the ProdysControlPlus application. All the controls are
configurable remotely. It is also possible to remote control the unit from the
ProdysControlPlus application as long as the unit is connected to the Internet,
and even when the unit is connected to the Internet through a firewall.
1Other compression modes might be offered as option. Please contact us at sales@prodys.net
for further information in this regard.

Prodys S.L. Tel: +34 91 6896880 Fax: +34 91 6943777 Email: sales@prodys.net Web: www.prodys.com
Page 7
Installation Guide
This chapter describes the QLST hardware installation.
II.1 Initial checks
Before unpacking the unit, please check its packaging for any signs of damage or
mishandling during transportation. Report any damage to the shipping company
immediately. Unpack the unit carefully, if you find any damage or the unit does
not work correctly, you should contact Prodys or its distributor as soon as
possible.
II.2 Setting the IP address
QLST default IP configuration is DHCP, so if a codec is booted when connected
to a network with a DHCP server, this will assign a free IP address to the codec
in the established DHCP range.
When the user has a touch panel connected to the QLST, it’s very easy to find
out the IP address assigned by the DHCP server. It can be found in the “IP “ field
of Quantum Lite’s ‘Menu->Conf->Interfaces->Lan->IP’ menu:
Picture 2. QLST IP menu.
Chapter II

Prodys S.L. Tel: +34 91 6896880 Fax: +34 91 6943777 Email: sales@prodys.net Web: www.prodys.com
Page 8
Many times there is no visualization method available, so it’s important to follow
these steps to install the QLST:
1. Switch on the codec with the RJ45 cable directly connected between the
codec LAN1 connector and the computer.
2. Once the codec boots, without any DHCP server replying, it will set to the
default IP address 192.168.100.100
3. By means of your PC, IP address within the range 192.168.100.xxx,
connected to the LAN1 connector of the QLST and access its control
webpage with a browser at the address 192.168.100.100.
4. Change the codec IP address manually selecting “Use the following” in the
aforementioned menu.
Picture 3. Setting the local IP.

Prodys S.L. Tel: +34 91 6896880 Fax: +34 91 6943777 Email: sales@prodys.net Web: www.prodys.com
Page 9
FRONT AND REAR PANELS
III.1 Front Panel
Picture 4. QLST front panel.
III.1.1 ON/OFF Button
This button turns the power on /off.
III.1.2 USB Display connector
This connector allows the user to plug and unplug the touch panel (hot insertion
is allowed).
Take into account that the touch panel menu orientation can be rotated 180º. To
rotate the display, click on ‘Menu->Conf->System->Display->Rotate Display’.
III.1.3 LEDs
There are three LEDs in the front panel
ALARM: (Blinking red) An alarm event is taking place.
SYS: (Green) The codec is on and working.
PWR: (Blue) Power is on.
Chapter III

Prodys S.L. Tel: +34 91 6896880 Fax: +34 91 6943777 Email: sales@prodys.net Web: www.prodys.com
Page 10
III.2 Rear Panels
There are two different rear panel configuration depending on the kind of
input/ouputs: analog or digital:
Picture 5. QLST rear panel (digital)
Picture 6. QLST rear panel (analog)
III.2.1 Power supply
QLST comes supplied with an AC/DC converter (12 volts output) to be connected
to the power connector <VDC INPUT> located at the rear panel. The power
converter works with an AC input range of 100 to 240 VAC, 50 to 60 Hz.
III.2.2 Audio interfaces
III.2.2.1. Digital audio AES/EBU STEREO input/output
An AES/EBU interface is available via three XLR connectors on the rear panel of
the unit. The central connector provides the option to connect an externally
synchronised signal. The user can select via software if the digital output is to
synchronise with the audio input or with an external sync signal. The connectors
are wired in the following way:
Tabla de contenidos
Otros manuales de Sistema de conferencias de Prodys
Manuales populares de Sistema de conferencias de otras marcas

Kramer
Kramer VIA GO Manual de usuario

AVT
AVT MAGIC AC1 Go Manual de usuario

ProSoft Technology
ProSoft Technology AN-X4-AB-DHRIO Manual de usuario

Sony
Sony PCS-I150 Manual de usuario

Middle Atlantic Products
Middle Atlantic Products VTC Series Manual de usuario

Prentke Romich Company
Prentke Romich Company Vanguard Plus Guía