4. OPERATION
1. Place the degausser on a stable surface.
2. Connect the power cord to the degausser and then to a power outlet.
3. Install the media slide in the catch located below media output.
4. Turn on the power button and then the START / STOP button - this button will glow green.
5. Wait until the message "Load disk" appears on the display. The device is ready for
operation.
6. Place the data carrier in the media input.
7. The degaussing process is in progress, the message on the display
"Erase cycle finished -OK" informs about its successful completion.
8. The degaussed storage medium will automatically pop up onto the media slide.
9. Remove the medium from the media slide.
10. As soon as the message "Load disk" appears on the display, you can start another
degaussing cycle.
11. Opening the media input while the degaussing is in progress, stops the process, and the
display shows "WARNING cycle terminated". To recover the medium, press the RESET
button.
12. If you want to interrupt the degaussing cycle, press the RESET button. The storage
medium will automatically pop up onto the media slide.
13. In order to properly turn off the device, after completing the degaussing cycle, press the
START / STOP button and the main power switch.
14. Disconnect the power cord from the power outlet and then from the degausser.
Instruction manual ProDevice ASM240
9