to use, the gearing, the axis bearings, the
spiral of the crank, and the sections.
5.3 - All lifts should undergo an annual
technical inspection carried out by an
authorized VMB dealer to check the cer-
tications and general condition of all the
lift’s elements and security systems invol-
ved in the lift’s use.
5.4 - Only use original spare parts to gua-
rantee a continued security level. The
user loses all rights to warranty if any spa-
re parts other than originals are used or
carries out any modication or alteration
to the towerlift.
5.5 - To request a spare part please in-
dicate the corresponding code which can
be found in this manual together with the
lift’s serial number and year of manufac-
ture.
6. GUARANTEE.
The warranty period for this lift is 2 years
from the date of purchase.
PRO LIFTS S.L. promises, that from the
date of purchase and during the warranty
period to resolve any faults that may oc-
cur, produced through defect material or
fabrication. Damage caused by improper
use, product modication, third party ma-
nipulation or accidental re are not cove-
red by this warranty.
certain point each tower will be extended
to a height different to that of the others.
For this reason it is necessary that the
structure does not stretch and allows
for these differences. With a rigid xa-
tion and if the level difference is signi-
cant, the force generated from the handle
of the winch will deform the structure and
apply a lateral force to the lifts causing
them to break and block.
4.7 - Transport:
For the transport of the tower is necessary
to fold the machine lowering every section
completely. Once the towerlift is comple-
tely folded, unlock the catch pawl (R) and
untighten the retainer knob (K), then rise
and close the support system (SA) up to
its transport position, then x the safety
catch pawl (R) and tighten the knob (K).
5. MAINTENANCE.
5.1 - Regularly check the state of the ca-
ble. If the cable has broken threads, or if
it shows any signs of crushed/attened
areas, it should be changed and replaced
immediately with a new one. Do not use
the lift if the cables are in bad condition.
Only use VMB steel cables reference: DIN
3060 torsion resistant.
5.2 - The lift is supplied from the factory
completely greased. However, it is recom-
mended to periodically grease according