9
EN
Technical Data
*The typical measurement uncertainty of ± 3 mm
is valid for measurements on white, diffusive,
reflective targets up to 5 m at low ambient light
and moderate temperatures. For distances
greater than 5 m, the measurement uncertainty
could increase additionally by 0.1 mm/m. In
unfavourable conditions (such as bright sunlight,
targets with poor reflectivity, or high or low
temperatures) the measurement uncertainty
could further increase up to ± 8 mm for distances
below 5 m and additionally by roughly 0.15
mm/m for distances greater than 5 m.
Message Codes
If the message Error does not disappear after
switching on the device repeatedly, contact the
dealer.
If the message InFo appears with a number,
press the Clear button and observe the
following instructions:
Care
• Clean the device with a damp, soft cloth.
• Never immerse the device in water.
• Never use aggressive cleaning agents or
solvents.
Disposal
CAUTION
The battery must not be disposed of
with household waste. Care for the
environment and take them to the
collection points provided in
accordance with national or local
regulations.The product must not be
disposed with household waste.
Dispose of the
product appropriately in
accordance with the national
regulations in force in your country.
Adhere to the national and country
specific regulations. Product specific
treatment and waste management
can be downloaded from our
homepage.
General
Range
0.05 - 80 m
0.16 - 265 ft
Measuring accuracy*
± 3 mm
± 1/8 in
Smallest unit displayed
1 mm
1/16 in
Laser class
Laser type
Autom. power switch-off
Continuous measuring
Area / Volume
Power supply
Recharging time
Battery service life in
measuring operation, approx.
Dimension(LxWxH)
2
620 nm - 690 nm
after 120 s
yes
yes
Weight (without batteries)
Temperature range:
- Storage
- Operation
-10 to 60 °C
14 to 140 °F
0 to 40 °C
32 to 104 °F
Prexiso P80E-8L
119 x 48 x 26.5 mm
4.7 x 1.9 x 1.0 in
81 g / 2.86 oz
No. Cause Correction
Lithium
Err10
Err15
Err16
Err18
Err26
Low battery
Out of measuring range
Received signal too
weak or measuring time
too long
Too much background light
The results out of maximal
digit on screen
Recharge the battery
Correct range
Change target surface
(e.g. white paper) and
remeasure
Shadow target area
Get the results by changing
units or calculate manually
Li-ion battery
< 3 h
5h