Prexiso P60LC Manual

IMPORTANT: Read before Using
P60LC
OFFOFF
C
UNITS
P60LC
®
LASER DISTANCE MEASURE
www.prexiso-eu.com
2WARRANTY
LIMITED
YEARS

1
EN
Table of Contents
Instrument Set-up ------------------------------ 2
Overview---------------------------------------------
Display---------------------------------------------------
Insert batteries ----------------------------------------
2
2
2
Operations ---------------------------------------- 3
Switching ON/OFF -----------------------------------
Unitsetting Change ----------------------------------
Measurement Reference --------------------------
3
3
3
Measuring Functions ------------------------- 4
Measuring single distance------------------------
Continuous measuring------------------------------
Area------------------------------------------------------
Volume--------------------------------------------------
Pythagoras(2-point)----------------------------------
Pythagoras(3-point)----------------------------------
Clear-----------------------------------------------------
Addition/Subtraction ---------------------------------
Angle Measurement ---------------------------------
4
4
4
5
5
6
6
6
7
Technical Data -----------------------------------
Message Codes ---------------------------------
Care -------------------------------------------------
Disposal -------------------------------------------
8
8
8
8
Safety Instructions ----------------------------
Warranty -------------------------------------------
Symbols used -----------------------------------------
Permitted use -----------------------------------------
Prohibited use ----------------------------------------
Hazards in use ---------------------------------------
Limits of use ------------------------------------------
Areas of responsibility -----------------------------
Electromagnetic Compatibility (EMC) ----------
FCC statement (applicable in U.S.) -------------
Laser classification ----------------------------------
9
11
9
9
9
9
9
10
10
10
11
Prexiso P60LC

Instrument Set-up
Overview
The safety instructions and the user manual should be
read through carefully before the product is used for the
first time.
The person responsible for the product must ensure that
all users understand these directions and adhere to them.
Display
Insert batteries
+
+
-
-
i
Change
batteries when
battery symbol
is empty.
Prexiso P60LC
P60LC
OFFOFF
C
UNITS
On / Measure /
Continuous
measuring
Units
Measuring
Reference
Add Sub
Area / Volume/
Pythagoras(2-Point
/3-Point)
Clear / Off
Color Display Units
Main line
Measuring
Reference
Area / Volume/
Pythagoras(2-Point/3-Point) BatteryAngle
2
EN

3
EN
Operations
Switching ON / OFF
ON OFF
Device is turned
OFF.
5 sec
i
If no key is
pressed for
120 sec, the
device
switches off
automatically.
If the info icon appears with a number, observe the
instructions in section "Message Codes".
Example:
Unit setting
Switch between
the following units:
Prexiso P60LC
OFFOFF
C
UNITS
Change the measurement reference
1 2
The system
default
measurements
start at the
bottom as a
reference point.
Press button
to change the
reference to
top for
measurement.
0.000 m
0.00 in
0.00 ft

UNITS
4
EN
Measuring Functions
Measuring single distance
1
Aim active laser at target.
2
59.99 m
3
i
Target surfaces: Measuring errors can occur
when measuring to colourless liquids, glass,
styrofoam or semi-permeable surfaces or when
aiming at hight gloss surfaces. Against dark
surfaces the measuring time increases.
Continuous measuring
3 sec
1 2
The largest and smallest
measured value appear
above it.
Stops continuous
measuring.
43
Area
1x
1 2
Aim laser at first
target point.
3 4
Aim laser at
second target
point.
24.352 m
2
5
i
The result is shown in the
main line and the measured
distance above.
Prexiso P60LC
Aim active laser at target.
min max
max
59.999 m
min
0.009 m

Measuring Functions
Volume
5
EN
2x
1 2
Aim laser at
first target
point.
3 4
Aim laser at
second target
point.
Aim laser at
first target
point.
Aim laser at
second target
point.
5
Aim laser at
third target
point.
6
78.694 m
3
7
i
The result is shown in the main
line and the measured distance
above.
Prexiso P60LC
Pythagoras(2-point)
90°
1 2 3 4
The result is
shown in the
main line and
the measured
distance
above.
3x
45.286 m
90°

39.999
—20.000
m
m
79.999
+20.000
m
m
EN
Prexiso P60LC
6
90° 90°
Pythagoras(3-point)
1 2
Aim laser
at first
target
point.
3
Aim laser at
second target
point(Perpen-
dicular to the
measuring
surface).
90°
4
Aim
laser at
third
target
point.
5
The result is
shown in the
main line and
the measured
distance
above.
4x
58.868
m
4
The result is
shown in the
main line and
the measured
distance
above.
1
Measure
the first
data.
59.999 m
3
Then
measure
the
second
data.
20.000
m
Clear
Addition/subtraction
2
Press the “+”or “-”
button to
add/subtract next
measurement from
the previous data.
1
Press button to
undo last action.
or
C/off

The result is shown in the main line
and the measured distance above.
Inclination measurement is
used to measure a slope or
incline (e. g ofstairs, railings,
when fitting furniture, laying
pipes, etc. )
EN
Prexiso P60LC 7
Angle Measurement
1 2
ON
3
40.8
º
36.0
º

8
EN
Technical Data
*The typical measurement uncertainty of ± 2 mm
is valid for measurements on white, diffusive,
reflective targets up to 5 m at low ambient light
and moderate temperatures. For distances
greater than 5 m, the measurement uncertainty
could increase additionally by 0.1 mm/m. In
unfavourable conditions (such as bright sunlight,
targets with poor reflectivity, or high or low
temperatures) the measurement uncertainty
could further increase up to ± 4 mm for distances
below 5 m and additionally by roughly 0.15
mm/m for distances greater than 5 m.
Message Codes
If the message Error does not disappear after
switching on the device repeatedly, contact the
dealer.
If the message InFo appears with a number,
press the Clear button and observe the
following instructions:
Care
• Clean the device with a damp, soft cloth.
• Never immerse the device in water.
• Never use aggressive cleaning agents or
solvents.
Disposal
CAUTION
Flat batteries must not be disposed
of with household waste. Care for
the environ-ment and take them to
the collection points provided in
accordance with national or local
regulations.The product must not be
disposed with household
waste.Dispose of the product
appropri-ately in accordance with
the national regulations in force
in your country. Adhere to the
national and country specific
regulations.Product specific
treatment and waste management
can be downloaded from our
homepage.
General
Range 0.09 - 60 m
0.29 - 196 ft
Measuring accuracy* ± 2 mm
± 3/32 in
Smallest unit displayed 1 mm
1/16 in
Laser class
Laser type
Autom. power switch-off
Continuous measuring
Area / Volume
Dimension (H x D x W)
2
635 nm, < 1 mW
after 120 s
yes
yes
Battery durability (2 x AAA) up to 3000
measurements
Weight
(without batteries)
Temperature range:
- Storage
- Operation
-10 to 60 °C
14 to 140 °F
0 to 40 °C
32 to 104 °F
Prexiso P60LC
115 x 43.5 x 24.7 mm
4.52 x 1.71 x 0.97 in
81 g / 2.86 oz
No. Cause Correction
252 Temperature too high Let device cool
down.
253 Temperature too low Warm device up.
255 Received signal too
weak, measuring time
too long or outside of
measuring range
Change target
surface (e.g. white
paper)or correct
range.
204 Received signal too
high
Change target
surface (e.g. white
paper).
257 Too much background
light
Shadow target area.
Measurement outside
of measuring range Correct range.
Error

EN
Safety Instructions
The person responsible for the instrument
must ensure that all users understand
these directions and adhere to them.
Symbols used
The symbols used have the following
meanings:
WARNING
Indicates a potentially hazardous situation
or an unintended use which, if not avoided,
will result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation
or an unintended use which, if not avoided,
may result in minor injury and/or
appre-ciable material, financial and
environ-mental damage.
Important paragraphs which must be
adhered to in practice as they enable
the product to be used in a technically
correct and efficient manner.
Permitted use
• Measuring distances
Prohibited use
• Using the product without instruction
• Using outside the stated limits
• Deactivation of safety systems and
removal of explanatory and hazard
labels
• Opening of the equipment by using tools
(screwdrivers, etc.)
• Carrying out modification or conversion
of the product
• Use of accessories from other
manufac-turers without express
approval
• Deliberate dazzling of third parties; also
in the dark
• Inadequate safeguards at the surveying
site (e.g. when measuring on roads,
construction sites, etc.)
• Deliberate or irresponsible behaviour on
scaffolding, when using ladders, when
measuring near machines which are
running or near parts of machines or
installations which are unprotected
• Aiming directly in the sun
Hazards in use
WARNING
Watch out for erroneous measurements if
the instrument is defective or if it has been
dropped or has been misused or modified.
Carry out periodic test measurements.
Particularly after the instrument has been
subject to abnormal use, and before,
during and after important measurements.
CAUTION
Never attempt to repair the product
your-self. In case of damage, contact a
local dealer.
WARNING
Changes or modifications not expressly
approved could void the user’s authority
to operate the equipment.
Limits of use
Refer to section "Technical data".
The device is designed for use in
areas permanently habitable by humans.
Do not use the product in explosion
hazardous areas or in aggressive
environments.
i
Prexiso P60LC 9
Tabla de contenidos
Otros manuales de Instrumento analítico de Prexiso

Prexiso
Prexiso X2 Manual de usuario

Prexiso
Prexiso P80E-8L Manual de usuario

Prexiso
Prexiso P50 Manual de usuario

Prexiso
Prexiso P100LCU Manual de usuario

Prexiso
Prexiso PVX-240 Manual de usuario

Prexiso
Prexiso P40B-3LI Manual de usuario

Prexiso
Prexiso PLT15 Manual de usuario

Prexiso
Prexiso PWX-1000M Manual de usuario

Prexiso
Prexiso P80 Manual de usuario
Manuales populares de Instrumento analítico de otras marcas

EXTOL PREMIUM
EXTOL PREMIUM 8820043 Instrucciones de instalación y funcionamiento

RIDGID
RIDGID SeeSnake Compact Manual de usuario

Teledyne
Teledyne 3000PA Manual de usuario

YDLIDAR
YDLIDAR TIA Manual de usuario

Olympus
Olympus IPLEX FX Series Manual de usuario

Bosch
Bosch GLM 50 C Professional Manual de usuario