Rev1.0 191107 3
Optical power unit:dBm、mW are optional
Buzzer alarm:ON、OFF are optional
RF control mode:AGC、MGC are optional
MGC attenuation:0-20 are optional
AGC Offset:±3dB is optional
Set the optical power attenuation mode:AUTO、Manu are optional this menu is not
visible without the
WDM model.
Set the optical power attenuation:0~15dB are optional.
Set the difference between the main optical power and the inserted
o
tical
ower
Set SBS,13~20dB,0.5dB stepping
Number of channels:0-100 are optional
Set the local IP address
Set the subnet mask
Set gateway
Restore factory configuration
Laser output optical power
optical power after the attenuator, this menu is not visible without the WDM model.
External optical input power, this menu is not visible without the WDM model.
Laser bias current
Internal temperature of the laser
Laser cooling current
Number of transmission channels of the system
Laser drive level
RF control mode
AGC Offset (This menu is only available in AGC mode.)
MGC Attenuation (This menu is only available in MGC mode.)
Wavelength
+5V Monitoring voltage
-5V Monitoring voltage
+24V Monitoring voltage
Serial number
Current temperature inside the machine
IP address of this machine
Subnet mask of this machine
Gateway of this machine
MAC address of this machine
机内软件系统的版本号
SetLaserOutputUnit dBm
Set BuzzerAlarm ON
SetRF ControlMode AGC
Set MGC ATT XX dB
Set AGC Ref XX dB
Set OPT ATT Mode AUTO
Set OPT ATT XX dB
Set OPT Delta XX dB
Set SBS
SetChannel Number XX
Set IP Addr
Set Subnet Mask
Set GateWay
Laser Output xx dBm
Voa Input xx dBm
Master Input xx dBm
Laser Bias xx mA
Laser Temp xx ℃
Tec current xx A
RF Chan No xx
Laser RF xx dBuV
RF Ctrl Mode AGC
AGC Ref x dB
MGC ATT x dB
Wave Length 1550
+5V Read x v
-5V Read x v
+24V Read x v
S/N
BOX Temp xx ℃
IP Address
Mask
GTW
Mac
SoftWare Ver
Drive level alarm:The default normal range is 80 to 110dBuV, which can be set through the network management.
Laser temperature alarm:The default normal range is 25±10°C, which can be set through the network management.
Laser bias current alarm:The default normal range is 20 to 90 mA, which can be set through the network management.
Laser cooling current: The default normal range is -1.5~1.5A, which can be set through the network management.
Output optical power alarm: The default normal range is 2 to 25 mW, which can be set through the network management.
+5V alarm:The default normal range is 5±1V, which can be set through the network management.
-5V alarm:The default normal range is -5±1V, which can be set through the network management.
+24V alarm:The default normal range is 24±2V, which can be set through the network management.
Disp Parameters Level 2 submenu:
Set Parameters Level 2 submenu:
Alarm Status Level 2 submenu:
Laser RF
Laser Temp
Laser Bias
Laser TEC
Laser Output
+5V Alarm
-5V Alarm
+24V Alarm
Cordoba – Argentina - www.unicorsa.com.ar