Instruction Manual SDI-TG-EL-D4B-xx-x-0 page 3 of 38 Revised 3/8/22
Preferred Utilities Manufacturing Corporation Firmware 1.06
Specifications
Inputs (15 total)
Analog: (8) 4-20 mA or contact closure
Each channel field-configured
Intrinsically Safe: Class 1, Zone 0, Group CD
Voc = 29.9, Isc= 99.5mA, Po= 0.75W
Resolution: 0.007%
Accuracy: 0.1%
Discrete: (2) 120 VAC, 13 mA
(5) 24 VDC, sinking, internal pull-up
Outputs (14 total)
Analog: (2) 4-20mA, 16 bit
650 ohms max, volume or depth
Relays: (4) SPST NO, 1.5A pilot, 120Vac
(2) SPDT, 10A 250Vac
Discrete: (6) 24 Vdc, 200mA, Sinking
Requires external power supply
Instrument
Input power: 120 VAC +/-15%, 50/60 Hz, 26 VA
Enclosure: Nema 12 Faceplate
Bezel: 3 7/8 w x 8 h x 1 d
Rear Case: 3 1/2 w x 7 9/16 h x 4 7/8 d
Panel Cutout: 3.61 w x 7.65 h
Ambient temp.: 32° to 131° F (0-55° C)
Display: Color Touch Screen
Communications
RS485: Modbus RTU, 4800-57600 baud
Ethernet: Modbus TCP
USB: for D4B_Edit config. Read/Write
Printer
Input power: 120 VAC +/-15%, 50/60 Hz, 20 VA
Size: 4.6"H x 4"W x 2.8"D
Enclosure: Nema 1
Ambient temp.: 32° to 122° F
Paper: 2.25" W, thermal, 30 columns
Ordering Information
No enclosure, no printer 00
Wall-mount enclosure, no printer E0
Wall-mount enclosure, with printer EP
Magnetostrictive Level Sensor…………..…………TG-EL-MSxx
Single Float, (1) 4-20mA
Magnetostrictive Level Sensor……………..TG-EL-MSxx-D420
Dual Floats, Fluid and Water levels, (2) 4-20mA
Wire float level sensor, 4-20 mA
(See TG-EL-WF for dimensional information.)
7-ft. max. depth ............................................. TG-EL-WF-7-C
12-ft. max. depth ........................................... TG-EL-WF-12-C
Submersible head level sensor, 4-20 mA
7-ft. max. depth, #2 oil and diesel ................ TG-EL-HLT-7-C
15-ft. max. depth, #2 oil and diesel .............. TG-EL-HLT-15-C
Leak sensor, dry/water/oil, 4-20mA
25-ft. sensor .......................................................... HD-A2-C
8-ft. sensor ......................................................... HD-A2-C-8
Sensor guard for HD-A2-C for sumps, vault floors,
bright areas ................................................................... HD-HSG
Leak sensor, float actuated, day tank, double wall pipe ...... RBS
Leak sensor, pump set leak float switch ........................ PS-LDS
Two-wire direct burial cable .............................................. 92612
(For use with TG-EL-WF-x-C, RBS, HLS.)
Four-wire vented direct burial cable .................................. 26000
(For use with TG-EL-HLT-x-C.)
Fil-A-Larm Station (120 V)………………A-AV-xD3-SS
Printer for panel mounting ....................... TG-EL-D4x-PRINTER
(Shipped loose for TG-EL-D4B-00-x-0 or TG-EL-D4B-E0-x-0.)
Windows configuration software (not equired)………..D4B_Edit