PR electronics 9106A Manual de usuario

9106B
CCOE
HART®Transparent
Repeater
No. 9106V103-UK
Product version: 9106-002

1503
PR electronics A/S tilbyder et bredt program af analoge og digitale
signalbehandlingsmoduler til industriel automation. Programmet
består af Isolatorer, Displays, Ex-barrierer, Temperaturtransmittere,
Universaltransmittere mfl. Vi har modulerne, du kan stole på i selv
barske miljøer med elektrisk støj, vibrationer og temperaturudsving,
og alle produkter opfylder de strengeste internationale standarder.
Vores motto »Signals the Best« er indbegrebet af denne filosofi – og
din garanti for kvalitet.
PR electronics A/S oers a wide range of analog and digital signal
conditioning devicdes for industrial automation. The product
range includes Isolators, Displays, I.S. Interfaces, Temperature
Transmitters, and Multifunctional Devices. You can trust our products
in the most extreme environments with electrical noise, vibrations
and temperature fluctuations, and all products comply with the most
exacting international standards. »Signals the Best« is the epitome
of our philosophy – and your guarantee for quality.
PR electronics A/S ore une large gamme de produits pour le
traitement des signaux analogiques et numériques dans tous
les domaines industriels. La gamme de produits s’étend des
transmetteurs de température aux acheurs, des isolateurs aux
interfaces SI, jusqu’aux modules universels. Vous pouvez compter
sur nos produits même dans les conditions d’utilisation sévères,
p.ex. bruit électrique, vibrations et fluctuations de température.
Tous nos produits sont conformes aux normes internationales les
plus strictes. Notre devise »SIGNALS the BEST« c’est notre ligne
de conduite - et pour vous l’assurance de la meilleure qualité.
PR electronics A/S verfügt über ein breites Produktprogramm
an analogen und digitalen Signalverarbeitungsgeräte für die in-
dustrielle Automatisierung. Dieses Programm umfasst Displays,
Temperaturtransmitter, Ex- und galvanische Signaltrenner, und
Universalgeräte. Sie können unsere Geräte auch unter extremen
Einsatzbedingungen wie elektrisches Rauschen, Erschütterungen
und Temperaturschwingungen vertrauen, und alle Produkte von
PR electronics werden in Übereinstimmung mit den strengsten
internationalen Normen produziert. »Signals the Best« ist Ihre
Garantie für Qualität!
DK
UK
FR
DE

9106 - Product version 9106-002 1
HART®TRANSPARENT REPEATER
9106B
CONTENTS
Warning....................................................................................................... 2
Symbol identification............................................................................ 2
Safety instructions................................................................................. 2
How to demount system 9000 ........................................................ 4
Technical characteristics...................................................................... 5
Applications............................................................................................... 6
PR 4501 display / programming front........................................... 7
Mounting / demounting the PR 4501/4511............................... 8
Visualisation in 4501 of hardware / software error................ 13
Connections .............................................................................................. 14
Block diagram........................................................................................... 15
Signal error indications without display front ............................ 16
Configuration / operating the function keys............................... 17
Routing diagram...................................................................................... 19
Routing diagram, Advanced settings (ADV.SET)........................ 20
Scrolling help texts in display line 3............................................... 21
Appendix.................................................................................................... 22
IECEx Installation Drawing.............................................................. 23
ATEX Installation Drawing............................................................... 28
FM Installation Drawing ................................................................... 33
INMETRO Installation Drawing ...................................................... 38
Safety Manual....................................................................................... 44

9106 - Product version 9106-002 2
SYMBOL IDENTIFICATION
Triangle with an exclamation mark: Read the manual before installation
and commissioning of the device in order to avoid incidents that could lead
to personal injury or mechanical damage.
The CE mark proves the compliance of the device with the essential
requirements of the directives.
The double insulation symbol shows that the device is protected by
double or reinforced insulation.
Ex devices have been approved according to the ATEX directive for use in
connection with installations in explosive areas. See installation drawings
in appendix.
SAFETY INSTRUCTIONS
DEFINITIONS
Hazardous voltages have been defined as the ranges: 75...1500 Volt DC, and
50...1000 Volt AC.
Technicians are qualified persons educated or trained to mount, operate, and also
troubleshoot technically correct and in accordance with safety regulations.
Operators, being familiar with the contents of this manual, adjust and operate
the knobs or potentiometers during normal operation.
WARNING
The following operations should only be carried out on a discon-
nected device and under ESD-safe conditions:
General mounting, connection and disconnection of wires.
Troubleshooting the device.
Repair of the device and replacement of circuit breakers must
be done by PR electronics A/S only.
WARNING
Do not open the front plate of the device as this will cause dama-
ge to the connector for the display / programming front PR 4501.
This device contains no DIP-switches or jumpers.

9106 - Product version 9106-002 3
RECEIPT AND UNPACKING
Unpack the device without damaging it and check whether the device type
corresponds to the one ordered. The packing should always follow the device
until this has been permanently mounted.
ENVIRONMENT
Avoid direct sunlight, dust, high temperatures, mechanical vibrations and shock,
as well as rain and heavy moisture. If necessary, heating in excess of the stated
limits for ambient temperatures should be avoided by way of ventilation.
The device must be installed in pollution degree 2 or better.
The device is designed to be safe at least under an altitude up to 2 000 m.
MOUNTING
Only technicians who are familiar with the technical terms, warnings, and instruc-
tions in the manual and who are able to follow these should connect the device.
Should there be any doubt as to the correct handling of the device, please contact
your local distributor or, alternatively,
PR electronics A/S
www.prelectronics.com
The use of stranded wires is not permitted for mains wiring except when wires
are fitted with cable ends.
Descriptions of input / output and supply connections are shown in the block
diagram and on the side label.
The device is provided with field wiring terminals and shall be supplied from
a Power Supply having double / reinforced insulation. A power switch shall be
easily accessible and close to the device. The power switch shall be marked as
the disconnecting unit for the device.
For installation on Power Rail 9400 the power is supplied by Power Control Unit
9410.
Year of manufacture can be taken from the first two digits in the serial number.
CALIBRATION AND ADJUSTMENT
During calibration and adjustment, the measuring and connection of external
voltages must be carried out according to the specifications of this manual. The
technician must use tools and instruments that are safe to use.

9106 - Product version 9106-002 4
NORMAL OPERATION
Operators are only allowed to adjust and operate devices that are safely fixed in
panels, etc., thus avoiding the danger of personal injury and damage. This means
there is no electrical shock hazard, and the device is easily accessible.
CLEANING
When disconnected, the device may be cleaned with a cloth moistened with
distilled water.
LIABILITY
To the extent that the instructions in this manual are not strictly observed,
the customer cannot advance a demand against PR electronics A/S that would
otherwise exist according to the concluded sales agreement.
HOW TO DEMOUNT SYSTEM 9000
Picture 1:
By lifting the bottom lock, the device
is detached from the DIN rail.

9106 - Product version 9106-002 5
HART®TRANSPARENT REPEATER
9106B
• 24 VDC supply via power rail or connectors
• Active and passive mA input
• Active or passive output via the same two terminals
• Splitter function - 1 in and 2 out
• SIL2/SIL3 Full Assessment and certified acc. to IEC 61508
Application
• 9106B is a 1- or 2-channel isolated 1:1 repeater barrier for intrinsic safety
applications.
• The device supplies 2-wire SMART transmitters and can also be used for 2-wire
SMART current sources. HART & BRAIN protocols are supported and are trans-
ferred bi-directionally.
• 9106B can be mounted in the safe area or in zone 2 / Cl. 1, div. 2 and receive signals
from zone 0, 1, 2 and zone 20, 21, 22 including mining / Class I/II/III, Div. 1, Gr. A-G.
• The PR 4501 displays the process value for each channel and can be used to
define high and low limits for detection of loop current level. If these limits are
exceeded, the status relay will activate.
• In the 1-channel version the status relay can be used as a simple limit switch.
• Ex splitter application - 1 input and 2 outputs.
• In the dual channel version the 9106B can be implemented in a SIL3 loop.
Advanced features
• The PR 4501 detachable display and the green and red front LEDs indicate
operation status for each channel.
• A tag number can be defined for each channel.
• Monitoring of error events and cable breakage on input via the individual status
relay and/or a collective electronic signal via the power rail.
Technical characteristics
• High galvanic isolation of 2.6 kVAC.
• Fast response time <5 msec.
• High accuracy better than 0.1%.
• 2-wire transmitter supply >16 V.

44
43
42
41
44
43
42
41
12
11
14
13
31
32
33
34
54
53
52
51
COMMUNICATION FOUNDATION
COMMUNICATION FOUNDATION
COMMUNICATION FOUNDATION
COMMUNICATION FOUNDATION
Tx
+
-
+
-
Tx
+
-
+
-
mA
+
-
mA
mA
+
mA
+
+
-
9106 - Product version 9106-002 6
APPLICATIONS
Rail, +24 VDC
Rail, Gnd.
Power rail
Status relay signal
Zone 0, 1, 2,
20, 21, 22, M1 &
Cl. I/II/III, Div. 1
gr. A-G
Zone 2 & Cl. 1, Div. 2, gr. A-D
or Safe Area
Device status
Device status
Gnd. -
Supply +19.2...31.2 VDC
N.C.
No connection
No connection
Power connection:
Channel 2
Output signals:
Analogue, 4...20 mA
Input signals:
Channel 1
2-wire
transmitter
Current
Passive 2-wire
Current
2-wire
transmitter
Same power rail as above
Channel 1
Channel 2

9106 - Product version 9106-002 7
PR 4501 DISPLAY / PROGRAMMING FRONT
Functionality
The simple and easily understandable menu structure
and the explanatory help texts guide you effortlessly and
automatically through the configuration steps, thus making
the product very easy to use. Functions and configuration
options are described in the section ”Configuration /
operating the function keys”.
Application
• Communications interface for modification of operational parameters in 9106B.
• When mounted in the process, the display shows process values and device
status.
Technical characteristics
• LCD display with 4 lines:
Line 1 (H=5.57 mm) shows status for each channel (OK or error).
Line 2 (H=3.33 mm) shows loop current in mA for channel 1 or tag no.
Line 3 (H=3.33 mm) shows loop current in mA for channel 2 or tag no.
Line 4 shows communications status.
• In order to protect the configuration against unauthorised changes, access to
the menus can be blocked by a password.

OK
4501
1
3
4
2
3
9106 - Product version 9106-002 8
MOUNTING / DEMOUNTING THE PR 4501/4511
1: Insert the taps of 4501/4511 into the holes at the top of the device.
2: Swing 4501/4511 into place.
Demounting of 4501/4511
3: Push the release button on the bottom of 4501/4511 and swing 4501/4511
up.
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Reloj de repetición de PR electronics