Assembling the equipment
Assemble the high-pressure cleaner as shown in Fig. 2-7.
Water inlet connector (Fig. 1/13)
The connection for the water inlet (13) is equipped with a connector for
standard hose coupling systems. Remove the transport cap (fig.5) and attach
the hose coupling on the supply hose (min. Ø 1/2“) to the connector for the
water inlet (13).
Connecting the high-pressure hose (Fig. 1-2; 5-6/18)
Remove the transport cap as shown in Fig. 5 from the connection for
the high-pressure hose (9). Connect the high-pressure hose (18) to the
connection on the high-pressure cleaner (9) (Fig. 6) and on the spray gun
(14) (Fig. 2).
Fitting the gun attachments
The normal lance or the lance with rotating nozzle can be attached prior to
using the high-pressure cleaner (Fig. 2)
Lance point / wide cone (16)
The shape of the water jet can be changed from concentrated to flat
jet by turning the nozzle (Fig. 9).
Lance with rotating nozzle (17)
To remove particularly stubborn dirt, use the lance with rotating nozzle (17).
Electrical connections (Fig. 1)
• Beforeyouconnecttheappliancetothemainssupplymakesure
that the data on the rating plate is identical to the mains data.
• Ifyouuseanyextensioncables,makesurethattheyaresuitable
for outdoor use and have large enough wires:
1 – 10m: 1.5 mm2
10 – 30m: 2.5 mm2
• Plugthemainsplug(8)onthepowercable(6)intothemains
socket outlet.
Helpline No. UK/Northern Ireland 0151 6491500 Rep. Ireland 1890 946244
Web Support www.einhell-uk.co.uk
Model Number: 43736 05