Oricom NFS100 Manual de usuario

User Manual
NFS100
Infrared Forehead
Thermometer
NFS100 is included as a medical device on the Australian
Register of Therapeutic Goods (ARTG No. 198436).
NFS100 is intended for use as a measuring device for determining the patient's body temperature.
ALWAYS READ THE LABEL AND USER GUIDE, USE ONLY AS DIRECTED.
Keep this user guide for future reference. Always retain your proof of purchase in case of
warranty service and register your product on line at AUSTRALIA: www.oricom.com.au
Please visit www.oricom.com.au for the latest copy of the user manual.
Oricom Customer Support: 1300 889 785 or (02) 4574 8888
NFS100 user manual Jan 2014.indd 1 2015-1-21 09:13:42

2
Need Help?
If you need assistance setting up or using your Oricom product now or in the
future, call Oricom Support.
Australia 1300 889 785 or (02) 4574 8888
www.oricom.com.au
Mon-Fri 8am – 6pm AEST
New Zealand 0800 67 42 66
www.oricom.co.nz
Mon-Fri 10am – 8pm NZST
Contents
Warnings...............................................................................3
Principle of Measurement.......................................................5
Temperature Ranges .............................................................6
Product Descriptions ..............................................................7
How to Use NFS100...............................................................8
Memory Feature ....................................................................9
Mode Change (C F)............................................................10
Battery Replacement............................................................10
Probe Replacement..............................................................11
Cleaning Storage .................................................................12
Indications of Errors .............................................................13
Product Specications..........................................................14
Customer Support................................................................15
Warranty information ...........................................................16
NFS100 user manual Jan 2014.indd 2 2015-1-21 09:13:42

3
Thank you for purchasing the Oricom NFS100 Infrared Forehead Thermometer
The NFS100 is an innovative thermometer using highly developed infrared
technology enabling clinical accuracy.
This new type of thermometer enables the user to measure temperature by
gently moving the sensor across the forehead.
To use this device correctly please follow the directions in this user guide.
The instructions provide important details on how to achieve accurate
measurements.
Warnings
!Please read this user guide carefully before initial use and
follow all instructions.
• Use this product only for its intended purpose as described in
this manual and follow all instructions.
• The measurement of temperature using this product does
not represent a Doctors medical examination.
• Consult with your medical professional if any abnormality is found.
• Do not take a temperature measurement over a scar or open tissue.
• Do not expose the product to temperatures below 20C
(68F) or above 50C (122F) or a relative humidity of 95% or
greater.
• Do not drop the thermometer as it may cause damage.
• Do not take temperature with this product near heat sources
such as in direct sunlight, near a replace or stove.
• Do not use this product if it is not working properly, contact
Oricom support.
• There are no user serviceable parts the only service required
is battery replacement and general cleaning please follow
instructions in this user guide.
• If the product is not going to be used for an extended period of
time please remove the battery and store the thermometer in a
cool dry place.
NFS100 user manual Jan 2014.indd 3 2015-1-21 09:13:42

4
• This product is NOT waterproof. Direct contact with water or
other liquids should be avoided.
• Do not leave the thermometer with infants or children at any
time.
• The protective glass over the lens is fragile, handle with care.
• Do not touch the glass of the infrared lens with bare ngers.
Warning
Many people may not have an elevated temperature even if
they are ill. In the. following cases please consult your medical
professional before using this product.
• Under 90-day-old infants
• People on steroids, antibiotics or antipyretics.
• People with compromised immune systems.
Cautions
• If your child is moving during the measurement it may result
in an inaccurate measurement due to the probe losing
contact with the skin please calm your child and try again.
• In forehead measurement, slowly move the product from
starting point to end for 3 seconds.
• The reliability of the measurement cannot be guaranteed if
the temperature is measured from parts of body that are not
recommended (anywhere other than the forehead or behind
the earlobe).
• Wait 30 seconds between repeat measurements.
• Similar to other thermometer, measurement error may occur
within a range of ± 0.2oC (± 0.4oF).
• Measurement should not be taken until completely relaxed at
normal room temperature.
NFS100 user manual Jan 2014.indd 4 2015-1-21 09:13:42

5
• Please note that measurement may be incorrect after
exercising, bathing or getting wet in the rain.
• For accurate measurement, make sure forehead is clean and
free from makeup.
• Temperature between right and left forehead could be
different. Always take the temperature from the same side of
the forehead.
• Measurement may be incorrect when low battery( ) signal
is indicated. Replace the battery and re-measure.
• When measuring the temperature of a liquid (milk, water)
place the probe as close as possible to the liquid but ensure
that it is not immersed into the liquid as this may damage
your thermometer.
Principle Of Measurement
According to Clinical studies the temperature of the blood in a major artery will
reect an accurate body temperature
.
This Infared Forehead Thermometer is designed to measure the temperature of
the skin over the temporal artery, a major artery of the forehead
.
The NFS100 is easy and gentle to use it is non-invasive unlike other types of
thermometers for measuring rectal ,oral underarm and ear areas.
NFS100 ensures faster and easier measurement with a degree of clinical
accuracy and several user-friendly functions.
NFS100 user manual Jan 2014.indd 5 2015-1-21 09:13:42

6
Temperature Ranges
Body temperature means internal temperature of body. Normal
temperature even in a healthy person can vary within a small
range. The temperature of a person measured in the evening is
normally 0.5C higher than early morning and is also affected
by the environment, time and activity. Refer to the table below to
nd out the normal body temperature ranges.
Normal temperature range at various parts of body
Armpit 34.7 ~ 37.3C (94.5 ~ 99.1F)
Mouth 35.5 ~ 37.5C (95.9 ~ 99.5F)
Rectum 36.6 ~ 38.0C (97.9 ~ 100.4F)
Ear 35.8 ~ 38.0C (96.4 ~ 100.4F)
Normal temperature range by age
0 ~ 2age 36.4 ~ 38.0C (94.5 ~ 100.4F)
3 ~ 10age 36.1 ~ 37.8C (97.0 ~ 100.0F)
11 ~ 65age 35.9 ~ 37.6C (96.6 ~ 99.7F)
Above 65age 35.8 ~ 37.5C (96.4 ~ 99.5F)
• Normal body temperature can vary between individuals it is
recommended that you record your body temperature when
you are healthy as a reference point.
NFS100 user manual Jan 2014.indd 6 2015-1-21 09:13:42

7
Product Descriptions
1. Probe
2. LCD Display
3. Power/Memory Button
4. Scan Button
5. Battery Cover
6. Carrying Case
7. Spare Probe
NFS100 user manual Jan 2014.indd 7 2015-1-21 09:13:43

8
How to Use NFS100
1. Press /mem button as illustrated.
2. All symbols are displayed on LCD when
started.
3. When ready symbol ( - - . - ) shows on
the display, thermometer is ready to
use.
4. Gently hold the NFS100 as illustrated.
Press and hold the scan button then
place the probe at and rmly on the skin.
5. Slowly slide the probe midline across
the forehead to the hairline keeping the
instrument flat and in contact with skin.
You should scan the forehead slowly,
just like wiping the skin, for 3 seconds
and then release the scan button.
Measurement should start from center of
the forehead.
6.
The unit beeps one time (1) per second,
the nal beep only occurs after the scan
button is released, the thermometer
should remain in contact with the skin
once the scan button is released until the
nal beep is heard
.
7. Read the temperature on display.
8. As per cautionary notices on pages 4-5 you should allow 30
seconds between each new measurement.
9. The thermometer will automatically turn off after one minute
of no-use.
NFS100 user manual Jan 2014.indd 8 2015-1-21 09:13:43

9
[NOTE ]
• Follow instructions 1 to 4 and 6 replace
only instruction 5 with instruction
below.
• Normally, the artery behind the earlobe does not provide
a sufficiently accurate reading. However, in this case due
to the effect of sweat lowering the temperature, taking the
temperature behind the earlobe may give a better result.
• Brush hair aside if covering the ear and wait for 30 seconds for
more accurate measurement. Then gently nestle the NFS100 on
neck directly behind earlobe and scan through the arrow direction
about 1~2cm (0.4~0.8inch) as illustrated for 3 seconds.
• You should slide the product until you hear a “beep” sound,
which indicates the end of the measurement, and then release it
from skin.
Memory Feature
NFS100 stores the last 8 readings
Last measured data is automatically stored in order to review the
stored temperature.
Pressing /mem will show MEM 1
Pressing /mem again will show
MEM 2
Pressing / mem third time will
show MEM 3
NFS100 user manual Jan 2014.indd 9 2015-1-21 09:13:43

10
Memory location with no data will not
be displayed.
Pressing and holding /mem for 5 seconds
deletes the memory.
Mode Change (C F)
To change from C to F press and hold the mem/. and scan
button at the same time for 2 seconds.
Battery Replacement
This product contains one lithium battery. When low battery indication
( ) is displayed on LCD, replace the battery as follows:
To remove the battery cover. Press and slide the
battery door as indicated by the arrow in the
illustration. To replace the battery. Using a pen or
similar probe press latch to release the battery.
Place the new battery with the "+" mark facing up.
Replace the battery door cover.
Don't throw used lithium batteries in the bin.
Keep them safely out of reach of children before
disposing them. Ask your local council for the
nearest location to dispose your batteries safely.
NFS100 user manual Jan 2014.indd 10 2015-1-21 09:13:46
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Termómetro de Oricom