Observator Instruments OMC-048 Manual de usuario

Users' Hardware Manual | OMC-048
Status:Released | Not confidential
Page 2 | 15
V1.4
Document history
The Observator range is in continuous development and so specifications may be subject to change
without prior notice. When in doubt about the accuracy of this document, contact the Observator Group.
Revision history
Version
Date
Amendments
Company, position
2020-7-1
Initial document creation
Observator, TDC
2020-8-4
Pre- release
Observator, TDC
1.0
2020-11-16
First Release
Observator, TDC
1.1
2021-12
Observator, TDC
1.2
2022-4
Revision to Hardware V1.03 only for review
Observator
1.3
2022-6
Release
Observator
1.4
2022-06-20
Release, minor textual corrections
Observator

Users' Hardware Manual | OMC-048
Status:Released | Not confidential
Page 3 | 15
V1.4
Preface
This manual is intended for the user of the OMC-048 Scriptable Data logger.
You will find all information related to the hardware v1.03 (released in June 2022).
Detailed and up to date information concerning drivers and firmware is available in the OMC-048
Configuration Manual, which is available for download on the Observator.com website.
It does not include explanation of the Python scripting language. It assumes Observator Instruments or a
third party supplies the Python application for your logger.
If you are interested in scripting the logger yourself, we kindly refer to the OMC-048 Webmanual, which is
available on our Observator.com website.

Users' Hardware Manual | OMC-048
Status:Released | Not confidential
Page 4 | 15
V1.4
For correct functioning of this system the OMC-048 Data logger and
connected sensors must be installed and commissioned according
installation instructions.
Note the correct power supply voltage:
This a 12-24VDC system
Use external fuse!
After end of life dispose this product according local regulations or
return to manufacturer.

Users' Hardware Manual | OMC-048
Status:Released | Not confidential
Page 5 | 15
V1.4
What’s in the box
1
OMC-048 Scriptable Data Logger
2
Micro SD card 32GB (installed in the logger
3
Backup battery 3V coin cell (installed in logger)
Type: BR2032
4
USB cable C-type

Users' Hardware Manual | OMC-048
Status:Released | Not confidential
Page 6 | 15
V1.4
Table of contents
1Introduction......................................................................................................................8
1.1 Hardware revision 1.03 ..................................................................................................................8
2First use............................................................................................................................8
2.1 Requirements ................................................................................................................................8
2.2 Installation SIM card & activation backup battery............................................................................9
3I/O Connections .............................................................................................................10
3.1 Pinning ........................................................................................................................................10
3.2 Ground connections.....................................................................................................................12
3.3 USB connection...........................................................................................................................12
Appendix A: Specifications:...................................................................................................13
Appendix B: Declaration of Conformity.................................................................................14

Users' Hardware Manual | OMC-048
Status:Released | Not confidential
Page 7 | 15
V1.4

Users' Hardware Manual | OMC-048
Status:Released | Not confidential
Page 8 | 15
V1.4
1 Introduction
This versatile data logger is the successor of the successful OMC-045-3 data logger. It has a large
number of inputs and outputs, including SDI-12, ModBus and analog. The OMC-048 uses the latest
technology and includes a powerful processor as well as a state-of-the-art LTE ‘world wide’ modem for
connecting to the cellular network.
Thanks to the advanced processor and the availability of a large collection of input and output drivers, it is
possible to write your own programs (Python scripts) for maximum flexibility. For common applications,
scripts will be available for you to download, so most users will be able to use the logger without any
programming.
1.1 Hardware revision 1.03
This manual assumes you have the updated hardware 1.03.
Main differences with previous version:
1. 1 switchable 12VDC power output has been converted to 5VDC (Available outputs are now: 3 x 12VDC
and 1 x 5VDC).
2. The reset button is updated to a software controlled reset, button on previous version resulted in a hard
reset.
3. Internal ADC for (logger) power supply voltage monitoring.
4. Vref output changed from 2.5V to 5V.
2 First use
2.1 Requirements
For setting up your OMC-048 Scriptable Data Logger you will require the following:
1. USB –C cable (included)
2. PC / laptop
3. Terminal program
4. External power supply *
5. Cellular antenna (suitable for the band you will use)
6. Sensors (optional)
7. Phillips screwdriver
8. 2mm flat screwdriver
* Configuration & firmware updates are possible with USB power, external power is required for starting
the application!

Users' Hardware Manual | OMC-048
Status:Released | Not confidential
Page 9 | 15
V1.4
2.2 Installation SIM card & activation backup battery
When you receive your OMC-048 Scriptable Data Logger, it might or might not already have been
configured by Observator Instruments. For the following steps we assume it has not.
1. Use a suitable Philips screwdriver to remove the 2 screws of the right cover.
2. Remove the right cover
3. Remove plastic strip from coin cell (if not already removed)
4. Place Nano SIM card (without pin code, check and disable with a phone).
5. Reinstall cover
6. Tighten the 2 screws.

Users' Hardware Manual | OMC-048
Status:Released | Not confidential
Page 10 | 15
V1.4
3 I/O Connections
3.1 Pinning
Connector
Description
Remarks
Power supply input
12- 24 VDC
Note: Power input is
protected but not internally
fused.
Use an external fuse
Switchable power supply
3 x12VDC, 1x 5VDC
Max 200mA nominal per
output
Peak power 500mA (1 port!)
For sensor use.