4
B
A
G
E
F
D
C
UNCERTAIN IMPLEMENTATION TIME, CAN WE PUT: EARLY PRODUCTION: 5/16-37T JIC INLET/OUTLET.
LATE PRODUCTION: 1/4 NPT INLET OUTLET?
A- Connect the exhaust elbow of the diesel engine to the exhaust system of the vessel.
B- Connect the sea water pump to the vessel’s water inlet. Pass a 3/4” ID hose from the vessel’s sea water strainer through
hole B to the sea water pump inlet tting.
C- Connect the vessel’s fuel supply and fuel return to the generator set through hole C. Fuel connections are located at the
fuel manifold on the base frame of the generator’s left hand side. Size will be 1/4” NPT or 5/16” JIC-37T depending on year
of manufacture. Use Coast Guard-approved rubber hose only.
D- Connect the DC control panel harness to the genset engine harness plug through hole D.
E- Connect the 12 volt battery leads to the generator set through hole E.
F- Connect the AC output leads from the generator junction box to the vessel’s power distribution panel through hole F.
G- “OPTIONAL” This port is used for water outlet in KEEL COOLED applications.