Norsat ATOMSKU Series Manual de usuario

1
ATOM Ka 25/40W/50W BUC & SSPA
USER MANUAL
ATOM Ku 80W BUC & SSPA

© Norsat International Inc. (“Norsat”) All Rights Reserved
2022-07-04 908236 Rev C 2
ATOM 80W BUC & SSPA
Operator’s Manual
The information in this document has been fully reviewed and is believed to be entirely reliable. However,
Norsat International Inc., hereinafter referred to as Norsat, reserves the right to modify any products to
improve reliability, function, or design. Norsat does not assume any liability arising out of the application or
use of any product or circuit described herein. Norsat does not convey any license under its patent rights
or the rights of others.
Technical Support
This manual provides engineers with information necessary to operate the applicable system. Technical
support is available from Norsat.
Norsat International Inc.
Attn: Technical Support
110 –4020 Viking Way
Richmond, BC
Main: 1 (604) 821-2800
Support: 1 (800) 644-4562

© Norsat International Inc. (“Norsat”) All Rights Reserved
2022-07-04 908236 Rev C 3
Table of Contents
1.1 Overview ...................................................................................................................... 7
1.2 Features....................................................................................................................... 7
1.3 Safety........................................................................................................................... 8
2.1 Introduction................................................................................................................... 9
2.2 J1 & J6–Inputs and Grounding ...................................................................................11
2.3 J3 –DC/AC Power ......................................................................................................11
2.4 J2 –Monitor and Control Interface...............................................................................13
2.5 J4 –RF Output............................................................................................................27
2.6 Ground Connection .....................................................................................................27
2.7 Indicators / LEDs.........................................................................................................27
3.1 ATOM Installation........................................................................................................28

© Norsat International Inc. (“Norsat”) All Rights Reserved
2022-07-04 908236 Rev C 4
3.2 Fans & Baseplate Cooling ...........................................................................................29
3.3 Accessories.................................................................................................................29
3.4 General Specifications.................................................................................................29
3.5 Standard Warranty ......................................................................................................30

© Norsat International Inc. (“Norsat”) All Rights Reserved
2022-07-04 908236 Rev C 5
List of Figures
Figure 2-1: Input Connections for ATOM 80W DC Unit………………………………………. 9
Figure 2-2: Input Connections for ATOM 80W AC Unit………………………………………. 10
Figure 2-3: Standard Waveguide Output for ATOM 80W units……………………………… 10
Figure 2-4: Optional Waveguide to Coax adaptor…………………………………………….. 10
Figure 2-5: DC Unit J3 Connector Pinout……………………………………………………….12
Figure 2-6: AC Unit J3 Connector Pinout……………………………………………………….13
Figure 2-7: J2 M&C Connector Pin Arrangement……………………………………………... 14
Figure 2-8: RJ-45 Plug Pinout……………………………………………………………………18
Figure A-3-1: 80W SSPA with AC Input & SMA Output……………………………………….31
Figure A-3-2: 80W BUC/SSPA with DC Input WR62/75 Output, Fan Cooled……………… 32
Figure A-3-3: 80W BUC/SSPA with DC Input WR62/75 Output, Baseplate Cooled………. 33

© Norsat International Inc. (“Norsat”) All Rights Reserved
2022-07-04 908236 Rev C 6
List of Tables
Table 1-1: Input and Outputs..................................................................................................... 7
Table 2-1: DC Unit J3 Connector Pinout ..................................................................................12
Table 2-2: AC Unit J3 Connector Pinout...................................................................................13
Table 2-3: M&C Interface Options.............................................................................................14
Table 2-4: J2 Pinouts for ATOM Configurations........................................................................15
Table 2-5: ATOM Mute Control Behavior ..................................................................................16
Table 2-6: RS-485 Address Assignment ...................................................................................17
Table 2-7: Ethernet Cable Pinout..............................................................................................18
Table 2-8: Serial Port Interface Setup......................................................................................19
Table 2-9: Getident Parameters and Data Types......................................................................22
Table 2-10: Getstatus Parameters and Data Types ..................................................................23
Table 2-11: Getmute Parameters and Data Types....................................................................24
Table 2-12: Indicators / LEDs....................................................................................................28
Table 3-1: General 80W ATOM Specifications..........................................................................29
Table B-3-1: Acronyms and Abbreviations................................................................................34

© Norsat International Inc. (“Norsat”) All Rights Reserved
2022-07-04 908236 Rev C 7
Introduction
1.1 Overview
This operator’s manual applies to all ATOM SSPAs and BUCs with the following marketing numbers:
ATOMSKUxxx (080W)
ATOMBKUxxx (080W)
This includes any ATOM that uses the 80W (P1dB) Ku Extended Band (13.75-14.5GHz) mechanics, such
as a custom frequency band or power derated output unit.
SSPA - Solid State Power Amplifier
If this unit is a SSPA, the RF input signal is amplified to the specified power.
BUC - Block Up Converter and Amplifier
If this unit is a BUC, the IF input signal is upconverted to Ku-Band RF frequencies and then amplified to the
specified power.
1.2 Features
Inputs and Outputs Table 1-1: Input and Outputs
80W
Input Type
Female N-Type Connector (standard)
Female SMA-Type Connector (optional)
Output Type
Waveguide WR75 (standard)
Waveguide WR62 (optional/frequency dependent)
Electrical Interface
M&C Connector –a ten-pin connector is used to interface with a host computer. See Section 2.4 J2 –
Monitor and Control Interface for detailed description of the pinouts.

© Norsat International Inc. (“Norsat”) All Rights Reserved
2022-07-04 908236 Rev C 8
Power Connector –DC Units use a four-pin connector and AC units use a six-pin connector to provide
power to the ATOM. See Section 2.3 J3 –DC/AC Power for detailed description of pinouts.
Ground Terminal –a #10-32 screw is used to ground the chassis during use.
1.3 Safety
W A R N I N G
Leakage Current
The ATOM may exhibit high leakage current during use. Ensure
that the ground terminal is grounded according to local
electrical codes prior to powering on the ATOM.
W A R N I N G
RF Radiation Hazard
The ATOM emits high power RF energy which is harmful to the
human body. Do not operate ATOM unless the RF output flange
is either terminated in an RF load (80W min) or connected to
the feed of a terminal.
Do not obstruct the RF output or feed output with any body part.
W A R N I N G
Do not allow equipment to be standing in water.
While the BUC/SSPA is designed to be used outdoors, the
equipment is not designed to operate in standing water. Failure
to follow this precaution could result in electric shock and injury
to persons.
C A U T I O N
Do not allow any items to fall into the unit from the waveguide
opening.
C A U T I O N
Apply voltage to the AC/DC input connector only as specified in
the original configuration of this unit. Application of a voltage
outside the specified range may cause the unit to become
damaged or non-functional.

© Norsat International Inc. (“Norsat”) All Rights Reserved
2022-07-04 908236 Rev C 9
Interface Control
2.1 Introduction
The unit has three connectors on the input side of the housing and one waveguide port on the output side.
The interface for these connectors is detailed in this document.
On the input side, there are the following connectors:
•J1 –IF or RF Input; N-Type Jack or SMA-Type Jack
•J2 –Ten-pin circular connector for M&C
•J3 –Four-pin circular power connector for DC unit or six-pin circular power connector for AC unit
•J6 –Ground terminal
Figure 2-1: Input Connections for ATOM 80W DC Unit
J1
J6
J2
J3

© Norsat International Inc. (“Norsat”) All Rights Reserved
2022-07-04 908236 Rev C 10
On the output side, there is one connector:
•J4 –WR75 or WR62 waveguide RF output
•Optional Waveguide to Coax adaptor
J6
Figure 2-2: Input Connections for ATOM 80W AC Unit
J1
J2
J3
J4
Figure 2-3: Standard Waveguide Output for
ATOM 80W units
Figure 2-4: Optional Waveguide to Coax