Modular Analog Audio Router Rev. 8
2Specifications
2.1 Mechanics
Dimensions: HxWxD = 396x483x340mm, (19”, 9RU), or
HxWxD = 220x483x340mm, (19”, 5RU).
Backplane card: 128x128 Analog Stereo Audio (9RU), or
64x64 Analog Stereo Audio (5RU).
X-point Modules: 64x64 mono, 32x32 stereo audio module cards.
System Controller: 1 Syscon card required, must be specified, 1 redundant card
is optional.
GYDA-VX: 2 GYDA-VX cards, both optional.
Safety/Emission standards: Compliant with CE EN55103-1 and 2, FCC part 15.
2.2 Power Supply
Built-in, redundant power supply. 1 module included, 1 (redundant) optional.
Backplane card: 2x AC-inlets.
Main internal voltage: 36 - 72VDC.
AC Supply voltage range: 90-130VAC / 180-254VAC, switchable, 50-60Hz, 300W.
AC Mains connector: IEC 320, separate input for each PSU module.
Alarms: Power failure alarm on relay contact closure, LED in front,
and Open Collector to GYDA-VX.
Alarms connector: RJ45.
Safety standards: Compliant with CE EN60950, UL-1950/CSA22.2.
2.3 Control
Standard Features:
Audio control: - Stereo audio
-Left-/Right channel controlled independently.
Serial ports:
Connector:
-RS-232/RS-422 for protocol conversion, to VikinX
compact control protocol, or to third party protocols.
(1x per Syscon card).
-RS-232/RS-422 for new router control protocol.
(1x per Syscon card).
DB9, female.
Ethernet ports:
Connector:
-10/100BaseT Ethernet bus for external router control
with new protocol. (1x per Syscon card).
-10/100BaseT Ethernet bus for GYDA-VX (1x per GYDA-
VX card).
RJ45.
Monitored parameters: - Module temperature.
-Internal module voltages.
Status surveillance: On each card with LED, and via system controller.
Configuration storage: Removable compact flash card.
9