PRODUCT DATA
CHANGING YOUR
CHANNEL SETTINGS
Any connected utilities need to be connected
to a ‘Turned On’ channel. Here is a quick walk
through a channel set up.
Navigate to this screen via NETTHINGS,
CONFIGURATION then CHANNELS
CHANGING YOUR
PULSE SETTINGS
When monitoring utilities via pulse you
will have to adjust the scale to match
the pulse of the connected equipment.
Navigate to this screen via NETTHINGS,
CONFIGURATION then SETTINGS and
select PULSE CONFIGURATION in
APPLICATION OPTIONS
Name of Manufacturer NetThings Limited
Unique reference number (model number) NT01:00:00
Purpose of product (Energy Manager) Monitoring building energy consumption
Dimensions 165mm x 95mm x 52mm
Operating temperature range 0°C to 40°C
Enclosure protection IP 20
Level of protection from electric shock Double insulation
Case material V0 rating Rated re retardant
Supply Voltage 220-240V AC
Max power in watts 7W
Power Supply Frequency Hz 50-60 Hz
WiFi IEE 802.11 Frequency Band EEE 802.11 BG 2.4 GHz
Type of Memory & Data Storage Capacity Internal-4Gb storage greater than 2 years External-microSD card slot for downloading data
Power supply for display 12W Switching Power Supply: I/P 90-264VAC unterminated wire for
spur connection. O/P USB Connection DC 5V. 82.5mm x 40mm x 29mm
Number of monitored channels Up to 6: Max of 3 x Electricity via CTs & 3 x any pulse enabled meter
CT Current Transformer related measurements (16mm/24mm) Kilowatt and kilowatt/hour kW and kW/h
Real-time, instantaneous Measurements Energy units consumed £/h (gas, water, electricity, heat, cooling, solar power)
Continued Utility Measurements Historical total energy consumed in currency and kW/h. Carbon CO2
WiFi Security WiFi Protected Access (WPA) security protocol and certication program
IMPORTANT
Whilst NetThings takes all reasonably practical steps
to design and manufacture its products to comply with the
requirements of the Health and Safety at Work Act 1974, all
products must be properly used and purchasers are reminded
that their obligations under the Act are to ensure that the
installation and operation of such products at a place of work
should be safe and without risk to them. Do not place the product
where it may be affected by dust, moisture, adverse temperature,
radio interference or be subject to physical damage.
Do not insert any objects into the Energy Manager or Display.
CAUTION Do not connect or disconnect CTs with the device
powered up as terminals will be at mains potential!
This information is for reference only. Accuracy may vary
depending on the type of connection and wiring system used.
CARE AND MAINTENANCE: The NetThings Energy Manager
or Display require no regular maintenance. Do not spray with
water or any cleaning products.
WHAT’S IN THE BOX?
1 x NT Measurement Unit, 1 x 5” Table display,
1 x aluminium tamper free wall mount, 1 x display power
supply, 1 x CT 16mm and 2 x pulse cable free end 10m
plus User and Installation guide.
DECLARATION OF CONFORMITY This product conforms to: ETSI EN 301 489- 1 V1.4.1 (2002- 08) IEC 61643, 61326, 61010, 60529. NetThings Limited, 14 New Mart Road, Edinburgh EH14 1RL
NetThings policy is one of continuous improvement and development. The right to change specication and appearance without prior notice is reserved. Document Number 200SM035 Rev.1.2.
This eld doesn’t need changed.
Change this to match the correct unit value of energy.
Input the correct pulse value here.
This eld doesn’t need changed.
Save your changes.
Select the type of pulse you want to congure here rst.
Change the channel type so that the icon is correct.
Indicate what the channel usage will be.
The channel name can be changed to represent
what is being monitored.
The Monthly balance can be left at zero.
Select the tariff that suits the utility being monitored.
Save your changes.
If on channels 1 to 3 select the correct CT (default is
CT16) If on pulse channels 4 to 6 select pulse value.
Select the channel that is to be congured.