Introduction & disclaimer 3
Guarantee 4
NEMTEK group outlets 5
Foreword 6
Mounting & battery replacement 7
PC Board replacement 8
Connections 9
Fence wiring diagrams 10
4-zone installation 12
Network cards and NEMTEK Connect 13
Large network 14
Solar installation 15
Detailed service indicators & fuses 16
Installation notes 17
Programmable options 18
Programmable options summary 29
Document revision history 30
Table of Contents
2

INTRODUCTION
The DRUID LCD 20 is a low voltage (less than 50V peak), fence monitoring system, which will
alert the user if a fault condition (open-circuit or short-circuit) is introduced to the fence. For
increased security the DRUID LCD 20 can be used in conjunction with an electric fence
energizer, provided the energizer output energy is 8 joule or less.
The unit is battery (12V 7AH nominal) operated and suitable for connection to mains power
(AC 100V-240V, 50-60Hz).
The batteries to be used are rechargeable lead-acid batteries. Non-rechargeable batteries must
not be used. The lead-acid batteries require venting and it is imperative that the unit be
situated in a well-ventilated area. A new fully charged battery will typically provide in excess of
24 hours backup.
DISCLAIMER
NEMTEK Holdings (Pty) Ltd or any of its subsidiary companies does not guarantee that the
operation of the product will be uninterrupted or totally error free.
Specifications may be altered without prior notification.
Introduction & disclaimer
3

GUARANTEE
The Druid LCD 20 fence monitoring system, manufactured by NEMTEK, is guaranteed for a
period of two years from date of sale against defects due to faulty workmanship or materials.
NEMTEK will, at its discretion, either repair or replace a product that proves to be defective.
NEMTEK guarantees that the product, when properly installed and used in line with the
specification as determined by NEMTEK from time to time, will execute its function of
generating a suitable potential. NEMTEK does not guarantee that the operation of the product
will be uninterrupted and totally error free. Faulty units must be returned to one of the NEMTEK
Group outlets. The buyer shall pay all shipping and other charges for the return of the product
to NEMTEK or NEMTEK Security Warehouse.
LIMITATION OF GUARANTEE
The guarantee does not apply to defects resulting from acts of God, modifications made by the
buyer or any third party, misuse, neglect, abuse, accident and mishandling.
EXCLUSIVE REMEDIES
The remedies provided herein are NEMTEK’s sole liability and the buyer’s sole and exclusive
remedies for breach of guarantee. NEMTEK shall not be liable for any special, incidental,
consequential, direct or indirect damages, whether based on contact, tort, or any other legal
theory. The foregoing guarantee is in lieu of any and all other guarantees, whether expressed,
implied, or statutory, including but not limited to warranties of merchantability and suitability
for a particular purpose.
Guarantee
4

NEMTEK Group outlets
HEAD OFFICE - NORTHRIDING
Tel: +27 (0)11 462 8283/4 Northriding Commercial Park, Stand 251,
Email: websales@nemtek.co.za Aintree Avenue, Northriding, Randburg, South Africa
EXPORTS
EDENVALE
Tel: +27 (0)11 453 1970 Unit 1 & 2, Eden Crossing, Corner Dick Kemp
and Herman Road, Edenvale, South Africa
CAPE TOWN
Tel: +27 (0)21 386 3742 21 Concord Crescent, Airport City
Or Tel: +27 (0)21 386 3100 Cape Town, South Africa
PORT ELIZABETH
Tel: +27 (0)41 581 4130 Unit 4, 51 Leadwood Crescent, Fairview
Or Tel: +27 (0)41 581 4064 Port Elizabeth, South Africa
PINETOWN
Tel: +27 (0)31 701 2125 19 Henwood Road, Pintetown, KwaZulu-Natal
Or Tel: +27 (0)31 701 3131 South Africa
NELSPRUIT
Tel: +27 (0)13 752 2187 44 Rapid Road, Riverside Industrial Park
Nelspruit, South Africa
BLOEMFONTEIN
Tel: +27 (0)51 004 0490 Plot 42, Gemsbok Street, Unit 12, Quaggafontein,
Bloemfontein, South Africa
TRAINING
Northriding Commercial Park, Stand 251,
Aintree Avenue, Northriding, Randburg, South Africa
AUSTRALIA
Tel: +61 8 9303 9855 Unit 5, 19 Innovation Circuit,
Wangara, 6065, Perth, WA, Australia
Website: www.nemtek.com
E-mail: nemtek@nemtek.com
Manufactured in South Africa
5

The DRUID LCD 20 should ideally be operated by means of a remote keypad to obtain
access to the many monitoring features and receive the greatest protection. It can
however be operated by means of a NEMTEK tab or external switch.
The unit includes many user and installer settings. These will be retained in the event of
total power loss, like when the battery is exhausted during a prolonged mains failure.
The unit can be configured as a master only, 2 zone installation, or as a master and slave
networked 4 zone installation. Only a master unit can communicate with keypads and
other devices present on the keypad bus.
A set of jumpers positioned above each of the three unit’s relays, allow the relay contacts
to be configured as either wet (providing 12V nominal power) or dry (potential free)
contacts.
The unit’s display will light with a blue (OFF), green (all is OK), yellow (alarm in history or
other medium priority event) or red (active alarm condition exists) background to
announce the system state at a glance and from a distance.
NEMTEK Connect
NEMTEK Druid LCD 20 units can be upgraded for remote connectivity through a
smartphone application or internet browser via NEMTEK Connect. Contact NEMTEK for
more information on the hardware and software upgrades required.
Foreword
6

Mounting & battery replacement
7
STEP 1: Disconnect mains. Open the lid after
removing the two cap screws. Unplug the
battery terminals if connected.
STEP 2: Remove screws and battery bracket
STEP 3: Remove battery
*Dispose of old battery according to legal
requirements. Do not replace with a non-
rechargeable battery!
STEP 4: Use a drilling template and drill 4 x
8mm holes in the wall for mounting the unit.
Four nail-in anchors are supplied with the unit.
Insert the plastic sleeve of the nail in anchor
into the wall then hammer the screw in with a
screwdriver and hammer. Leave a gap slightly
more than the thickness of the casing between
screw heads and wall. Position the casing so
that the screws go through the slots provided
then drop it into position. Tighten the top 2
screws to secure the casing. The bottom two
screws will slot into the casing for stability,
they don’t need to be tightened.
STEP 5: Insert battery with the negative
terminal to the top.
STEP 6: Place the battery bracket back (with
plastic offsets at the top) and fasten the
screws into place.
STEP 7: Connect battery wires. Close the lid
by hooking the top of the lid in first and then
fasten the bottom down with the two cap
screws. Apply mains power to the unit.
Note: Unit to be mounted vertically against a flat
surface, in a well-ventilated area.
Avoid prolonged exposure to direct sunlight.

PC Board replacement
8
STEP 1: Disconnect mains power and the
battery terminals if connected.
STEP 2: Remove all seven connectors,
C1 – C7.
STEP 3: Remove the five screws, S1 – S5.
STEP 4: To remove the PC Board, gently
pull the PC Board away from the mounting
plate, unplugging it from the connectors
beneath it. There are four spade connectors
beneath the PC Board in the middle of the
board.
STEP 5: To replace the PC Board, align the
four spade connectors in the middle of the
PC Board using the guide tabs, and gently
press the PCB down into place.
STEP 6: Re-insert and tighten the five
screws.
STEP 7: Reconnect the seven connectors to
the PC Board.
STEP 8: Reconnect the battery terminals
and apply mains power.

Connections
9
12V DC Strobe Light for
Zone 2
12V DC Strobe Light for
Zone 1
20W max 12V DC Siren
Radio alarm not to be
powered from unit!
Gate Switch
(Normally closed)
External On/Off Switch
for Zone 1
External On/Off Switch
for Zone 2
Panic Switch
(Normally closed)
A maximum of two NEMTEK
Druid 4-Zone keypads, two
expansion cards and 100m
of comms cable can be
connected.
A total of two units can
be linked together.
See; Creating a 4 zone
installation, later on in
this manual.

Fence wiring diagrams
10
Fence 1
Fence 2
The fence earth wire is
to be connected to the
main earth spike and
not directly to the unit.
All earth spikes are
connected to one wire of
the fence only, and this
one wire is connected to
the rest of the fence at the
main earth spikes.
Earth wire connection with earth loop monitoring (preferred)
The fence earth wire is
to be connected to the
main earth spike and
not directly to the unit.
Install the main earth
spikes close to the unit
Earth wire connection with no earth loop monitoring
Fence 1
Fence 2
Install the main earth
spikes close to the unit
Fence 1
Fence 2
The Druid LCD D20 can be connected to a standard electric fence installation, as a low
voltage substitute for an electric fence energizer. The installation and erection of an electric
fence in, South Africa, is to be done according to the latest addition of SANS 10222-3.
In other countries, according to relevant specifications.
Live wire connection
Otros manuales para Druid LCD 20
1
Tabla de contenidos
Otros manuales de Instrumento de medición de Nemtek
Manuales populares de Instrumento de medición de otras marcas

Endress+Hauser
Endress+Hauser Proline Promag 50 Especificaciones técnicas

Siemens
Siemens SITRANS F Coriolis FCT030 Manual de lista de piezas

KLINGER
KLINGER CMF V Series Manual de usuario

EXFO
EXFO FTB-2 Manual de operación y mantenimiento

Keysight
Keysight M8290A Manual de usuario

ADTEK
ADTEK MW-5 Manual de usuario