NCR RealScan 7875-7000 Manual de usuario

RealScan 7875-7000/8000
Installation Guide
16044
AIP-00342
Release C
Aug 16, 2007
Information Products
RSD-Atlanta

NCR RealScan 7875-7000/8000 Installation Guide
06/03 AIP-00342 Release B
2 of 56
The program products described in this book are licensed products of NCR Corporation. It is the
policy of NCR to improve products as new technology, components, software, and firmware
become available. Therefore, NCR reserves the right to change specifications without prior
notice. All features, functions, and operations described herein may not be marketed by NCR in
all parts of the world. Therefore, before using this document, consult your NCR representative or
NCR office for information that is applicable and current.
NOTE: Connection of EPOS/PC terminals to weighing or measuring devices requires
governmental approval before the connected devices can by placed into service for retail trade.
Before connecting any NCR device to a retail weighing or measuring system contact the NCR,
Weights and Measures Coordinator, Retail Atlanta to authenticate that NCR Certificates of
Conformance/Approval are not infringed.

NCR RealScan 7875-7000/8000 Installation Guide
AIP-00342 Release B 06/03 3 of 56
Contents
Contents..........................................................................................................................................3
Revision Record..............................................................................................................................5
Obtaining Additional Information..................................................................................................5
Obtaining Technical Assistance......................................................................................................6
System Components .......................................................................................................................7
NCR Components......................................................................................................................7
Sensormatic Components...........................................................................................................7
Step 1 – Verify and Prepare the Checkstand ..................................................................................8
Checkstand Cutout – RealScan 7875-7000/8000......................................................................8
Service Clearance.......................................................................................................................9
Item Diverter..............................................................................................................................9
Ventilation Requirements.........................................................................................................10
Electrical Wiring to the Checkstand ........................................................................................11
Specific Checkstand Modifications..........................................................................................12
Sensormatic Equipment ...........................................................................................................12
Step 2 – Connect the Components................................................................................................13
Install Sensormatic Antenna ....................................................................................................13
Connect Sensormatic Cables....................................................................................................14
Connect Remaining Components.............................................................................................15
Set the Communications Protocol Switch................................................................................16
Step 3 – Sensormatic Deactivation Setup.....................................................................................17
Power up the System................................................................................................................17
Specific Function Programming ..............................................................................................18
Step 4 – Install RealScan 7875.....................................................................................................19
Install RealScan 7875...............................................................................................................19
Align the RealScan 7875 to the Checkstand............................................................................20
Step 5 – Calibrate the Scale..........................................................................................................22
Set Scale AC Voltage Frequency.............................................................................................22
Exercise the Scale ....................................................................................................................22
Access the Calibration Switch .................................................................................................23
Calibrate the Scale ...................................................................................................................24
Verify the Calibration ..............................................................................................................24
Secure the Calibration Switch..................................................................................................26
Step 6 – Set Program Parameters..................................................................................................27
Setting the Program Parameters...............................................................................................27
Step 7 – Check the Scanner Operation .........................................................................................28
Scan Sample Tags....................................................................................................................28
Check Sensormatic Deactivation System.................................................................................29
Call Sensormatic ......................................................................................................................29
Operating the Scanner...................................................................................................................30

NCR RealScan 7875-7000/8000 Installation Guide
06/03 AIP-00342 Release B
4 of 56
Operating the Scale.......................................................................................................................31
Operating the Sensormatic Deactivation System..........................................................................32
Normal Operation ....................................................................................................................32
Manual Deactivation................................................................................................................33
Cleaning the RealScan 7875.........................................................................................................34
Correcting Scanner Problems .......................................................................................................35
Correcting Scale Problems............................................................................................................36
Isolating Sensormatic Problems....................................................................................................37
Voice Messages........................................................................................................................37
Tones........................................................................................................................................37
Programming Worksheets.............................................................................................................38
1 0 – Communications Protocol...............................................................................................38
1 1 – Good Read Tone.............................................................................................................38
1 2 – Timers.............................................................................................................................39
1 3 – Bar Codes - 1 ..................................................................................................................39
1 4 – Bar Codes - 2 ..................................................................................................................40
1 5 – Bar Codes - 3 ..................................................................................................................41
1 7 – Bar Codes - 4 ..................................................................................................................41
1 8 – Bar Codes - 5 ..................................................................................................................42
1 6 – Label Identifiers..............................................................................................................42
2 0 – RS-232 Parameters - 1 ....................................................................................................43
2 1 – RS-232 Parameters - 2 ....................................................................................................43
2 2 – RS-232 Prefix Byte.........................................................................................................44
2 3 – RS-232 Terminator Byte.................................................................................................44
2 4 – RS-232 Communications Options...................................................................................44
3 0 – Scale Parameters.............................................................................................................45
3 2 – Miscellaneous Parameters...............................................................................................45
3 6 – Dual Cable Interface Options..........................................................................................45
ASCII Code Chart....................................................................................................................46
Appendix A – Pan-Oston PO-2 ....................................................................................................47
Appendix B – Pan-Oston PO-2.....................................................................................................48
Appendix C – Pan-Oston PO-4.....................................................................................................49
Appendix D – Regulatory Information.........................................................................................50
Federal Communications Commission (FCC) Radio Frequency Interference Statement.......50
Voluntary Control Council for Interference (VCCI) Radio Frequency Interference Statement50
Canadian Department of Communications Radio Frequency Interference Statement............50
Scale Regulatory......................................................................................................................51
Declaration of Conformity.......................................................................................................52
Laser Safety .............................................................................................................................53

NCR RealScan 7875-7000/8000 Installation Guide
AIP-00342 Release B 06/03 5 of 56
Revision Record
Date Issue Pages Remarks
05/13/03 A 1 though 54 First Printing
06/02/03 B 12, 17, 29, 33 Updated to latest Sensormatic requirements
8/16/2007 C 20 Updated scale alignment section
Obtaining Additional Information
Other Information Products
Order Number Title
497-0001843 NCR RealScan 7875 Installation/Owner Guide
B005-0000-1085 NCR RealScan 7875 User Guide
B005-0000-1086 NCR RealScan 7875 Repair Guide
BST0-2121-74 NCR Scanner Programming Tags
BD20-1074-A NCR Scanner/Scale Interface Programmer's Guide
How To Obtain Information Products
Web Sites
•http://inforetail.AtlantaGA.NCR.COM
(NCR only)
•http://www.info.NCR.COM (Anyone)
Online Order
•Connect System (NCR only)
Phone Order
•800-543-2010 (US area)
•622-3727 (VOICEplus)
•44-181-242-5350 (International)
Fax Order
•937-445-6245 (US area)
44 (0) 20 8 242 5355 (International)
E-Mail
(US area)
R.COM (International)
Mail Order
•NCR Corporation IPP-Dayton
1529 Brown St.
IPP EMD-2
Dayton, OH 45479
USA
•NCR Corporation
915 High Road
North Finchley
London N12 0HN United Kingdom

NCR RealScan 7875-7000/8000 Installation Guide
06/03 AIP-00342 Release B
6 of 56
Obtaining Technical Assistance
Technical assistance is available as follows.
•Technical assistance in the United States: 1-800-262-7782
•Technical assistance in other countries: call your local NCR office
•To order parts: 1-800-438-7830
Note: If you find any defective parts during installation of a new scanner, contact the Customer
Satisfaction Hotline at one of the following.
•Phone: 1-800-528-8658 (USA)
•Phone: 770-623-7400 (International)
•E-mail: [email protected]

NCR RealScan 7875-7000/8000 Installation Guide
AIP-00342 Release B 06/03 7 of 56
System Components
NCR Components
Following are the required NCR components.
•NCR RealScan 7875-7000/8000
•Power Supply with Power Cord
•Interface Cable – appropriate for host terminal
•Sensormatic Communications Cable – 1416-C841-030
The RealScan 7875 is shipped with Shipping Spacers that must be removed before installing the
unit.
20790
Shipping Spacers (2)
Sensormatic Components
Following are the required Sensormatic components.
•Sensormatic ScanMaxTM Pro Controller – ZBSMPRO – with software version 6.6 or higher
•Sensormatic ScanMaxTM NS Pro Antenna – ZBSMPNS

NCR RealScan 7875-7000/8000 Installation Guide
06/03 AIP-00342 Release B
8 of 56
Step 1 – Verify and Prepare the
Checkstand
Checkstand Cutout –
RealScan 7875-7000/8000
20551
G
D D
H
I
A
B
E
C
C
D
ABCD E
11 5/8 in.
29.51 cm 20 1/16 in.
50.95 cm 1 3/8 in.
3.49 cm 3/8 in.
0.95 cm 17 5/16 in.
43.97 cm
7875-7200
Scanner
12 1/16 in.
30.63 cm 20 1/16 in.
50.95 cm 1 3/8 in.
3.49 cm 1/2 in.
1.27 cm 17 5/16 in.
43.97 cm
7875-8200
Scanner/Scale
7875-7200
Scanner
7875-8200
Scanner/Scale
FG
1 3/8 in.
3.49 cm 7 1/8 in.
18.1 cm
1 3/8 in.
3.49 cm 7 1/8 in.
18.1 cm
HI
7 1/4 in.
18.42 cm
7 1/4 in.
18.42 cm
Note: Dimension Afor a 7875-7200
includes a spacer along each side
of the unit so that it fits an existing
7870-2000 cutout.
Recommended shelf to catch
RealScan 7875 if dropped
during installation.
*
No electronics under RealScan 7875
C C
B
EF
A
F
*
7 3/8 in.
18.73 cm
7 1/4 in.
18.42 cm Note: Dimension Hincludes a
Produce Guard.

NCR RealScan 7875-7000/8000 Installation Guide
AIP-00342 Release B 06/03 9 of 56
Service Clearance
Item Flow Area
20784
A = 20.3 cm (8 in.) minimum if checkstand structure is not removable for servicing.
2.5 cm (1 in.) minimum if checkstand structure is removable for servicing.
B = 35.6 cm (14 in.) minimum if checkstand structure is not removable for servicing.
17.8 cm (7 in.) minimum if checkstand structure is removable for servicing.
C = 18.1 cm (7 1/8 in.) minimum clearance to closest checkstand panel.
The NCR 7875-7000/8000 must not be supported by a bottom panel.
Note: RealScan 7875-8000 units with a Produce Guard must have enough clearance to remove
the Produce Guard for cleaning. The dimensions given here satisfy these requirements.
Mounting surface for keyboard must be
removable for the following.
• Servicing the unit.
• Removing the 7875-8000 Produce Guard.
• Replacing the vertical window.
B
C
A A
Item Diverter
Item Diverter
(Must be removable to service
Scanner/Scale in checkstand)
7.25 in. (18.4 cm)
14957
Note: The Item Diverter is not used in most self-checkout installations.

NCR RealScan 7875-7000/8000 Installation Guide
06/03 AIP-00342 Release B
10 of 56
Ventilation Requirements
The RealScan 7875 is designed to operate without an exhaust fan in the checkstand; however,
there must be adequate convection airflow. The ambient temperature inside the checkstand
cannot be higher than 40° C (104° F). Also, the ambient temperature inside the checkstand
cannot be higher than 7° C (12.6° F) above the ambient temperature outside the checkstand. For
example, if the ambient temperature outside the checkstand is 24.4° C (76° F), the ambient
temperature inside the checkstand cannot be greater than 31.4° C (88.6° F). If the checkstand
contains other heat producing equipment, you may need to use forced air to keep the temperature
within the specified range. However, air coming into or leaving the checkstand MUST NOT
enter or exit past the RealScan 7875.
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Escáner de NCR

NCR
NCR 7702-K168 Manual de usuario

NCR
NCR Datalogic DSM0422 Manual de usuario

NCR
NCR Realscan 7837 Manual de usuario

NCR
NCR 7870 Manual de usuario

NCR
NCR 7409-K312 Manual

NCR
NCR 7409-K073 Manual

NCR
NCR 7872 Series Manual de instrucciones

NCR
NCR 7409-K332 Manual

NCR
NCR 7882 Manual de instrucciones

NCR
NCR 7409-K314 Manual

NCR
NCR SelfServ 90 R1.2 Manual

NCR
NCR RealScan 7837-3000 Manual de usuario

NCR
NCR Realscan 7837 Manual de usuario

NCR
NCR RealScan 7892 Manual de usuario

NCR
NCR RealScan 7892 Manual de usuario

NCR
NCR CX5 Manual

NCR
NCR SelfServ 90 Manual

NCR
NCR 7401 Web Kiosk Manual de usuario

NCR
NCR 7409-K321 Manual de usuario

NCR
NCR 7895 Manual de usuario