MultiScan TD-32 series Manual de usuario

INSTRUMENTS
MultiScan
OPERATING MANUAL
MODEL TD-32-R
INSTRUMENTS
PUSH FOR
SETTING
SELECTING
ENTER
UP/DOWN
AUSTRALIAN MADE
TD-32 SERIES
Suc Press +298 KPA
Dis Press +1099 KPA
Oil Press +198 KPA
Comp-Stat 1234 TS4cn
RECIPROCATING COMPRESSOR
CONTROLLER

2
TWITE INSTRUMENTS MultiScan MODEL TD-32-R OPERATING MANUAL
© Copyright 2012 Twite Instruments Pty. Ltd. All rights reserved.
No part of this publication may be reproduced, translated into another language,
stored in a retrieval system, or transmitted, in any form or by any means, electronic,
mechanical, photocopying, or otherwise without the prior written consent of
TWITE INSTRUMENTS Pty. Ltd.
Every precaution has been taken in the preparation of this publication.
TWITE INSTRUMENTS assumes no responsibility for errors or omissions. Nei-
ther is any liability assumed for damages resulting from the use of the information
contained herein.
with this unit are subject to change without notice.
Twite Instruments Pty. Ltd. or any of its Partners, Principals or Employees cannot be
held responsible or liable for any loss of product, produce or buildings where any of
Twite Instruments Pty. Ltd. Products are found to be responsible for the loss of any
product, produce or buildings.
TWITE INSTRUMENTS PTY. LTD. ®
A.C.N. 050 199 758
A.B.N. 41 050 199 758

TWITE INSTRUMENTS MultiScan MODEL TD-32-R OPERATING MANUAL
Contents
Terminal Numbers and Position 9
MultiScan positioning and Mounting 10

TWITE INSTRUMENTS MultiScan MODEL TD-32-R OPERATING MANUAL
Contents

TWITE INSTRUMENTS MultiScan MODEL TD-32-R OPERATING MANUAL
Contents

TWITE INSTRUMENTS MultiScan MODEL TD-32-R OPERATING MANUAL
Contents

TWITE INSTRUMENTS MultiScan MODEL TD-32-R OPERATING MANUAL

8
TWITE INSTRUMENTS MultiScan MODEL TD-32-R OPERATING MANUAL
INSTALLATION :-
INSTRUMENTS
PUSH FOR
SETTING
SELECTING
ENTER
UP/DOWN
AUSTRALIAN MADE
TD-32 SERIES
160mm
5 x 15mm
5 x 15mm 5 x 15mm
90mm
Height 80mm
Suc Press +298 KPA
Dis Press +1099 KPA
Oil Press +198 KPA
Comp-Stat 1234 TS4cn

9
TWITE INSTRUMENTS MultiScan MODEL TD-32-R OPERATING MANUAL
INSTALLATION :-
INSTRUMENTS
PUSH FOR
SETTING
SELECTING
ENTER
UP/DOWN
AUSTRALIAN MADE
TD-32 SERIES
7
4
1
8
5
2
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
R1
35
R2
36
R3
37
R4
42
51
46
55
43
52
47
56
44
53
48
57
45
54
49
58
50
59
60
61
62
63
64
65
X50
6
3
R5
R6
R8
R7
Suc Press +298 KPA
Dis Press +1099 KPA
Oil Press +198 KPA
Comp-Stat 1234 TS4cn
R1
R2
R3
R4
R5
R6
R8
R7

10
TWITE INSTRUMENTS MultiScan MODEL TD-32-R OPERATING MANUAL
INSTALLATION :-
The unit should be mounted at a level for easy viewing and access to setting knob,
in a dry area and not in direct sunlight and not subject to any vibration.
The unit must be mounted as far away from contactors, switching motors, sole-
noids etc. as possible and if possible mount the unit within its own cabinet.
NOTE:- If more than one MultiScan is connected to the same 24v dc power sup-
ply, all terminals numbered 2 must be connected to the same side of the 24v dc
(ground) and all terminals numbered 3 must be connected to the other side of the
24v dc (positive).
The power supply that is used must be used for the MultiScan only (not connect-
ed to any other units including a 24v DC TempScan) and the cable must not run
near or with any control cables.
The power supply cables must be kept away from any control cables that are
connected to the relay control outputs, also sensor and transducer cables must be
kept away from the control cables.
NOTE:-Terminal 1 and 2 are connected together on the circuit board.
NOTE:- The power supply for the unit should be left on at all times to conserve
the battery power for the Real Time Clock and Set Points memory. See Battery
Replacement later in this manual to change the battery.
INSTRUMENTS
1
2
57
58
59
60
61
62
63
64
65
3
GROUND
24V DC NEGATIVE
24V DC POSITIVE
X50