English
Tester MS016
10
2.3. Keep the tester far from the direct sunlight.
2.4. Keep away from heating devices, microwaves, and other temperature-raising equipment.
2.5. Avoid dropping the tester or spilling technical liquids on it.
2.6. Any interference with the electric diagram of the device is strictly prohibited.
2.7. Make sure the crocodile clips are completely insulated before connecting them to the
alternator/voltage regulator terminals.
2.8. Avoid the crocodile clips short circuit between themselves or to any conductive parts of a
vehicle, including its body.
2.9. Do not put the tester on the vehicle battery or other elements of the underhood space.
Avoid short circuit of the tester housing to the conductive parts of a vehicle.
2.10. Do not use the device with a faulty power unit.
2.11. Turn off the tester when it is not in operation.
3. In case of failures in the operation of the tester, stop further operation and contact the
manufacturer or sales representative.
WARNING! The manufacturer is not responsible for any damage or injury to human health
resulting from non-compliance with the requirements of this user manual.
5.1. Safety regulations
The operation of the tester requires technical proficiency of the operator, he must be authorized
to operate certain types of test benches (devices) and receive safety training.
5.2. Mode of operation
Mode 1 – Powered from a power unit.
Testing voltage regulators with a nominal voltage of 12/24V requires the use of a power unit: either
the one included in the equipment set or any other power unit with the «Quick Charge 2.0»
function. In this mode, the supply voltage (9V) will be displayed at the top of the tester screen.
When the tester is powered from a 5V power unit, the only available test mode is for 12V units.
WARNING! The operation of some voltage regulators requires heavy current that the tester
cannot provide. The diagnosis of such voltage regulators is not possible.
Mode 2 – Powered from a vehicle power system.
Use a diagnostic cable for alternators included in the equipment set (Fig.6). The tester will switch
on and function in alternator test mode only when we connect big crocodile clips “B+” and “B-“ to
the alternator output terminals.