MRC TM-9017SD Manual de usuario

PT 100 ohm, type K/J/T/R/E/S
PRECISION 0.01°
THERMOMETER
Model : TM-9017SD
Your purchase of this PRECISION THERMOMETER marks a step
forward for you into the field of precision measurement.
Although this METER is a complex and delicate instrument, its
durable structure developed. Please read the following
instructions carefully and always keep this manual within
easy
OPERATION MANUAL
PLEASE READ THIS MANUAL CAREFULLYBEFORE OPERATION
Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 [email protected]
MRC.1.22

TABLE OF CONTENTS
1. FEATURES..................................................................................................................................
1
2. SPECIFICATIONS........................................................................
...................................................
2
3. FRONT PANEL DESCRIPTION..................................................................
...........................
6
4. MEASURING PROCEDURE....................................................................
...........................
7
4-1 Function selection and measurement
..............................................................
7
4-2 T1-T2 measurement...............................................................
...........................
9
4-3 Data Hold..........................................................
......................................................
10
4-4 Data Record ( Max., Min. reading )...............................................................................................................
10
4-5 LCD Backlight ON/OFF
.........................................................................................
10
5. DATALOGGER................................................................................
......................................................
11
5-1 Preparation before execute datalogger function...............................................................................
11
5-2 Auto Datalogger ( Set sampling time ≧ 1 second ).......................
...........................
12
5-3 Manual Datalogger ( Set sampling time = 0 second )....................
...........................
13
5-4 Check time and sampling time information..........................................................................................................
13
5-5 SD Card Data structure..................................................................................................
14
6. Saving data from the SD card to the computer..................................
...........................
15
7. ADVANCED SETTING...............................................................................
...........................
17
7-1 Set clock time ( Year/Month/Date, Hour/Minute/ Second ).........
...........................
17
7-2 Set sampling time ................................................................................................................
18
7-3 Auto power OFF management ..........................................................
...........................
18
7-4 Set beeper Sound ON/OFF.................................................................
...........................
19
7-5 Decimal point of SD card setting................................................................................................
19
7-6
SD memory card format....................................................................................................
20
7-7 Select the temperature unit to ℃ or ℉
...............................................................
20
7-8 Select the Thermometer to Type K or Type J/T/R/E/S………………………………...
20
8. POWER SUPPLY from DC ADAPTER.....................................................
...........................
21
9. BATTERY REPLACEMENT............................................................
...........................
21
10. RS232 PC serial interface.................................................................................
22
11. OFFSET ADJUSTMENT.............................................................
...........................
24
12. Optional Type K Temp. probe.................................................................................
26
13. PATENT...........................................................................................................................................
26

1. FEATURES
* Type K/J/T/E/R/S, Pt 100 ohm, measurement .
*Type K : -100 to 1300 ℃.
*Type J : -100 to 1200 ℃.
*Pt 100 ohm : -199.99 to 850.00 ℃.
*℃/℉, 0.01 degree / 0.1 degree / 1 degree.
* 2 channels ( Pt 1, Pt 2, Pt 1- Pt 2 ), 1 channels
Thermocouple Type K or J/T/R/E/S .
* Microcomputer circuit provides intelligent function and high accuracy.
* Offset adjustment for the Type K/J/T/E/R/S measurement.
* Offset adjustment for the Pt 100 measurement.
*Measuring unit can select to ℃ or ℉.
* Real time SD memory card Datalogger, it Built-in Clock
and Calendar, real time data recorder, sampling time set
from 1 second to 3600 seconds.
* Manual datalogger is available ( set the sampling
time to 0 second ), during execute the manual datalogger
function, it can set the different position ( location ) No.
( position 1 to position 99 ).
* Innovation and easy operation, computer is not need to
setup extra software, after execute datalogger, just take
away the SD card from the meter and plug in the SD card
into the computer, it can down load the all the measured
value with the time information ( year/month/date/
hour/minute/second ) to the Excel directly, thenuser can
make the further data or graphic analysis by themselves.
* SD card capacity : 1 GB to 16 GB.
* LCD with green light backlight, easy reading.
* Can default auto power off or manual power off.
* Data hold, record max. and min. reading.
* Microcomputer circuit, high accuracy.
* Power by UM3/AA ( 1.5 V ) x 6 batteries or DC 9V adapter.
* RS232/USB PC COMPUTER interface.
* Heavy duty & compact housing case.
1

2. SPECIFICATIONS
2-1 General Specifications
Circuit Custom one-chip of microprocessor LSI
circuit.
Display LCD size : 51 mm x 30 mm
LCD with green backlight ( ON/OFF ).
Channels Pt1, Pt2, Pt1- Pt2, Thermocouple Type .
Sensor type Type K thermocouple probe.
Type J/T/E/R/S thermocouple probe.
PT 100 ohm probe
*Cooperate with an 0.00385 alpha
coefficient, meet DIN IEC 751.
Resolution 0.01℃/0.1℃/1℃, 0.01℉/ 0.1℉/1 ℉.
Datalogger Auto 1 second to 3600 seconds
Sampling Time @ Sampling time can set to 1 second,
Setting range but memory data may loss.
Manual Push the data logger button
once will save data one time.
@ Set the sampling time to
0 second.
@ Manual mode, can also select the
1 to 99 position ( Location ) no.
Data error no. 0.1% of total saved data max.
Memory Card SD memory card. 1 GB to 16 GB.
Advanced * Set clock time ( Year/Month/Date,
setting Hour/Minute/ Second )
* Set sampling time
* Auto power OFF management
* Set beep Sound ON/OFF
* Decimal point of SD card setting
* SD memory card Format
*Set temperature unit to ℃ or ℉
* Set thermocouple type to K/J/R/E/T/S.
2

Temperature Automatic temp. compensation for the
Compensation type K/J/T/E/R/S thermometer.
Linear Linear Compensation for the full range.
Compensation
Offset Available for Type K/J/T/E/R/S and
Adjustment Pt 100 ohm.
Probe Input Type K/J/T/E/R/S
Socket 2 pin thermocouple socket.
Pt 100 ohm : 4 DIN socket.
Over Indication Show " - - - - ".
Data Hold Freeze the display reading.
Memory Recall Maximum & Minimum value.
Sampling Time Approx. 1 second.
of Display
Data Output RS 232/USB PC computer interface.
* Connect the optional RS232 cable
UPCB-02 will get the RS232 plug.
* Connect the optional USB cable
USB-01 will get the USB plug.
Power off Auto shut off saves battery life or
manual off by push button.
Operating 0 to 50 ℃.
Temperature
Operating Less than 85% R.H.
Humidity
Power Supply * Alkaline or heavy duty DC 1,5V battery
( UM3, AA ) x 6 PCs, or equivalent.
* DC 9V adapter input. (AC/DC powerl
adapter is optional ).
3

Power Current Normal operation ( w/o SD card save
data and LCD Backlight is OFF) :
Approx. DC 13 mA.
When SD card save the data but and
LCD Backlight is OFF) :
Approx. DC 31 mA.
* if Backlight on, the power consumption.
will increase approx. 4mA
Weight 242 g/0.53 LB ( meter only ).
Dimension 177 x 68 x 45 mm
(7.0 x 2.7x 1.8 inch)
Accessories *
Instruction manual......................................
1 PC
Included
Optional * Type K thermocouple probe.
Accessories TP-01, TP-02A. TP-03, TP-04, TP-05.
* Pt 100 ohm probe, TP-100.
* SD Card ( 4 GB )
* USB cable, USB-01.
* RS232 cable, UPCB-02.
* Data Acquisition software,
SW-U801-WIN., SW-E802.
* AC to DC 9V adapter.
* Hard carrying case, CA-06.
* Soft carrying case, CA-05A.
2-2 Electrical Specifications (23±5
℃
)
PT 100 ohm
Resolution Range Accuracy
0.01 ℃-199.99 to 850.00 ℃± ( 0.1 % + 0.2 ℃ )
0.01 ℉-327.00 to 1562.00 ℉± ( 0.1 % + 0.4 ℉ )
*Pt 100 ohm probe TP-10 0 is the optional accessory.
4

Type K/J/T/E/R/S
Sensor Resolution Range Accuracy
Type
Type K 0.1 ℃-50.1 to -100.0 ℃ ± ( 0.4 % + 1 ℃ )
-50.0 to 1300.0 ℃ ± ( 0.4 % + 0.5 ℃ )
0.1 ℉-58.1 to -148.0 ℉ ± ( 0.4 % + 1.8 ℉ )
-58.0 to 2372.0℉ ± ( 0.4 % + 1 ℉ )
Type J 0.1 ℃-50.1 to -100.0 ℃ ± ( 0.4 % + 1 ℃ )
-50.0 to 1200.0℃ ± ( 0.4 % + 0.5 ℃ )
0.1 ℉-58.1 to -148.0 ℉ ± ( 0.4 % + 1.8 ℉ )
-58.0 to 2192.0 ℉ ± ( 0.4 % + 1 ℉ )
Type T 0.1 ℃-50.1 to -100.0 ℃ ± ( 0.4 % + 1 ℃ )
-50.0 to 400.0 ℃ ± ( 0.4 % + 0.5 ℃ )
0.1 ℉-58.1 to -148.0 ℉ ± ( 0.4 % + 1.8 ℉ )
-58.0 to 752.0 ℉ ± ( 0.4 % + 1 ℉ )
Type E 0.1 ℃-50.1 to -100.0 ℃ ± ( 0.4 % + 1 ℃ )
-50.0 to 900.0 ℃ ± ( 0.4 % + 0.5 ℃ )
0.1 ℉-58.1 to -148.0 ℉ ± ( 0.4 % + 1.8 ℉ )
-58.0 to 1652.0 ℉ ± ( 0.4 % + 1 ℉ )
Type R 1 ℃ 0 to 1700 ℃ ± ( 0.5 % + 3 ℃ )
1 ℉ 32 to 3092 ℉ ± ( 0.5 % + 5 ℉ )
Type S 1 ℃ 0 to 1500 ℃ ± ( 0.5 % + 3 ℃ )
1 ℉ 32 to 2732 ℉ ± ( 0.5 % + 5 ℉ )
Remark :
a. Accuracy value is specified for the meter only.
b. Accuracy is tested under the meter's environment temperature
within 23 ±5
℃
.
c. Linearity Correction :
Memorize the thermocouple's curve into the intelligent CPU
circuit,
@ Above specification tests under the environment RF Field Strength
less than 3 V/M & frequency less than 30 MHz only.
5

3. FRONT PANEL DESCRIPTION
Fig. 1
3-1 Display. 3-11 Reset Button
3-2 Power Button (Backlight Button )
3-12 DC 9V adapter socket
3-3 Hold Button 3-13 Battery compartment/Cover
3-4 REC Button 3-14 Battery Cover Screws
3-5 ▲ Button ( T1-T2 Button) 3-15 Stand
3-6 ▼ Button ( Function Button ) 3-16 Tripod Fix Nut
3-7 Time Button (SET Button ) 3-17 Thermocouple input socket (Type K/J/T/R/E/S )
3-8 Enter Button ( Logger Button) 3-18 PT2 input socket ( Pt 100 ohm )
3-9 SD card socket 3-19 PT1 input socket ( Pt 100 ohm )
3-10 RS-232 output terminal
6

4. MEASURING PROCEDURE
4-1 Function selection and measurement
1) Turn on the meter by pressing the " Power Button "
( 3-2, Fig. 1 ) > 1.5 seconds continuously.
*Pressing the " Power Button " ( 3-2, Fig. 1 )
continuously and > 1.5 seconds again will turn off the
meter.
2) The meter can select 5 kind function as :
a. Thermocouple Type , Pt1 , Pt2
b. Pt1 Thermometer.
c. Pt2 Thermometer.
d. Pt1, Pt2 Thermometer.
e. Thermocouple Type Thermometer.
Pressing the " Function Button " ( 3-6, Fig. 1 )
continuously ( not release the button ), the Display
will show the following text in sequence :
Until the Display show the desired mode ( Function ),
just release the " Function Button " ( 3-6, Fig. 1 ), the
meter will execute this function with default.
7

3) Thermocouple Type , Pt1 , Pt2 measurement
a. Plug the Thermocouple Probe into the "Thermocouple Probe
Input Socket " ( 3-17, Fig. 1 ).
Plug the Pt1 , Pt2 Probe into the " Pt Probe
Input Socket " ( 3-18 , 3-19 Fig. 1 ).
b. Power on the meter by pressing the " Power Button >1.5 Sec,"
( 3-2, Fig. 1 ).
c. Function select to " Thermocouple Type , Pt1 , Pt2 " measurement,
the LCD shows the unit " Type , " and " Pt1 " Pt2 "
at same time the measured value will show on the
display ( upper display is Thermocouple Type value, the lower
display is the temperature " Pt1 " and " Pt2 " value ) .
Remark :
The meter Temp. display unit is defaulted to "
℃
".
If intend to let the meter's temperature unit default
to "
℉
" , then please refer chapter 7-7 ( page 20 ).
Remark :
The meter is defaulted to " Type K thermometer ".
If intend to select the " Type J or T/R/E/S thermometer with
default , please refer chapter 7-8 ( page 20 ).
4) Pt1 Thermometer Temperature measurement
a. Function select to " Pt1 Thermometer ".
b. install the Pt Probe into the " ProbeInput Socket " ( 3-19, Fig. 1 ).
c. Function select to " Pt1 " measurement,the LCD shows
the unit " Pt 385 Pt1 Temp " at same time
the measured value will show on the display .
5) Pt2 Thermometer Temperature measurement
a. Function select to " Pt2 Thermometer ".
b. install the Pt Probe into the " Probe Input Socket " ( 3-18, Fig. 1 ).
c. Function select to " Pt1 " measurement,the LCD shows
the unit " Pt 385 Pt2 Temp " at same time
the measured value will show on the display .
8
Tabla de contenidos