MRC DW-6160 Manual de usuario

WATT/Leakage METER
Model : DW-6160 Your purchase of this
WATT/Leakage METER
marks a step forward for
you into the field of
precision measurement.
Although this
WATT/Leakage METER
is a complex and
delicate instrument, its
durable structure will
allow many years of use
if proper operating
techniques are
developed. Please read
the following
instructions carefully
and always keep this
manual within easy
reach.
OPERATION MANUAL

Caution Symbol
Caution :
* Risk of electric shock !
Caution :
* Do not apply the overload
voltage, current to the input
terminal !
* Remove test leads before open
the battery cover !
* Cleaning - Only use the dry
cloth to clean the plastic case !
Environment Conditions
*
Installation Categories II 600V.
*
Pollution Degree 2.
*
Altitude up to 2000 meters.
*
Indoor use.
*
Relative humidity 80% max.
Equipment protected throughout
by double insulation or reinforced
insulation.

TABLE OF CONTENTS
1. FEATURES................................................................. 1
2. SPECIFICATIONS.................................................... 2
2-1 General Specifications............................................ 2
2-2 Electrical specifications...........................................3
3. FRONT PANEL DESCRIPTION..................................... 6
3-1 Display..................................................................6
3-2 Backlight button................................................. 6
3-3 Record button ( MAX. / MIN. )............................... 6
3-4 Data hold button.................................................. 6
3-5 Power & function rotary switch .......................... 6
3-6 ACV / DCV & Ωinput terminal.............................. 6
3-7 Load terminal....................................................... 6
3-8 Power source terminal......................................... 6
3-9 Battery Cover / Compartment.................................6
3-10 Stand................................................................ 6
3-11 RS-232 output terminal........................................ 6
3-12 DC 9V power adapter input socket........................ 6
4. MEASURING PROCEDURES.......................................... 7
5. MAINTENANCE........................................................... 8
6. RS232 PC SERIAL INTERFACE.................................... 9
7. BATTERY REPLACEMENT........................................... 10
8. THE ADDRESS OF AFTER SERVICE CENTER..................11

1. FEATURES
* Professional WATT meter with Leakage current tester
digital display , battery operated .
* LSI - circuit provides high reliability and durability .
*Measurement
WATT ( AC ) : 2500W x 0.1 W / 1 W.
Leakage current ( AC mA ) : 80.00 mA x 0.01 mA.
ACV : 600.0 V x 0.01 V / 0.1 V.
ACA : 10.00 A x 0.001 A / 0.01 A.
DCV : 600.0 V x 0.01 V / 0.1 V.
Ω: 20 kΩx 0.01 kΩ/ 0.001 kΩ/ 1 Ω.
* Low Watt measurement , 999.9 Watt x 0.1 W.
* True Power and Wide range 0 to 2500 Watt.
* True RMS measurement of ACV / ACA.
* Leakage detect ( AC mA ) detection.
* Continuity beeper.
* Super large LCD , Dual display at same time.
* Full function Auto range.
* Memory Record ( Max. , Min. ) , Data Hold.
* RS232 / USB Computer interface.
* Built-in low battery indicator.
* Built-in backlight easy to readout .
* Power : DC 1.5V (UM-3 , AA ) x 8 PCs or DC 9V
adapter in.
1

2. SPECIFICATIONS
2-1 General Specifications
Circuit Custom one-chip of microprocessor
LSI circuit.
Display Large LCD display Max. reading 9999.
LCD size :90.5 x 64.5 mm.
Dual value display with backlight.
Measurement ACV 0 to 600.0 V
DCV 0 to 600.0 V
Ω0 Ωto 20.00 kΩ
WATT 0.1 W to 2500 W
Leakage 0.01 m A to 80.00 m A
current
ACA 0.01 A to 10.00 A
Over input " - - - - " mark indication .
Polarity Automatic switching , "-" indicates
reverse polarity.
Zero Adjustment Automatic adjustment.
Sampling Time Approx. 1.5 second.
Data Hold Freeze the display reading.
Memory Recall Maximum & Minimum value.
Data output RS232 / USB PC Computer interface .
* Connect the optional RS232 cable
UPCB - 02 will get the RS232 plug .
*Connect the optional USB cable
USB - 01 will get the USB plug .
Operation 0 to 50 (32 to 122 ) .℃℃℉ ℉
Temperature
Operation Less than 80% RH.
Humidity
2

Power Supply Alkaline or heavy duty DC 1.5 V battery
( UM3, AA ) x 8 PCs, or equivalent.
*
A
DC 9V adapter input. ( AC/DC power
adapter is optional ).
Power Approx. DC 33 mA
Consumption
Weight 883 g / 1.95 LB
Dimension 224 x 125 x 65 mm
( 8.8x 4.8 x 2.5 inch )
Standard Instruction manual................
.
1 PC
Accessories
T
est lead ( Red & Black ).......
.
1 pair
Included
Optional * AC/DC 9V adapter, AP-9VA.
Accessories * USB cable , USB - 01.
* RS232 cable , UPCB - 02.
* Data Acquisition software,
SW-U801-WIN.
* Hard carrying case , CA-08.
2-2 Electrical specifications (23±5 )℃
AC / DC VOLTAGE
Range Range 1 0.01V to 99.99V
Range 2 100 V to 600V
Resolution Range 1 0.01 V
Range 2 0.1 V
Accuracy ACV ± (1 %+5d)
DCV ± (0.8 %+5d)
* Measuring Signals come from the front panel terminals.
* Auto range.
* Max. input voltage : AC 600 V, DC 600 V.
* ACV accuracy is test under input signal is sine wave,
50/60 Hz
*ACV frequency response is from 40 to 400 Hz.
* ACV is true rms measurement..
3

OHMS ( Resistance )
Range Resolution Accuracy
0 to 999 Ω1 Ω± (1 % + 1d )
1.000 to 9.999 KΩ0.001 KΩ± (1 % + 1d )
10 to 20 KΩ0.01 KΩ± (1 % + 1d )
* Auto range.
* Continuity beeper : < 4 Ω.
* Overload Rating : AC / DC 600V at 20 second Max
WATT ( true power )
Range Resolution Accuracy
1000 W 0.1 W ± (1.5 % + 5d )
1001 to 2500 W 1 W ± (1.5 % + 5d )
* 0.1 W resolution : Input voltage < 120 AVC or
Input current < 1 ACA.
Beyond above input, the resolution will still be 1 W.
*Measuring Signals come from the top power plug input..
* Accuracy is test under input signal is sine wave, 50/60 Hz
* ACV, ACA frequency response is from 40 to 400 Hz.
* Max. input voltage : AC voltage 250 V, AC current : 10 A.
Leakage ( AC mA )
Range Resolution Accuracy
0 to 80 mA 0.01 mA ± (1 % + 5d )
*The leakage current that sense between the " Hot line " and the "
Earth " of the measuring installation that connect to the output "
Power plug "
4

V, A ( true rms )
Range Resolution Accuracy
ACV 250 V 0.01 V/0.1 V ± (1 % + 5d )
ACA 10 A 0.001 A/0.01A ± (1 % + 3d )
* ACV, 0.01 V resolution is valid from 0.01 V to 99.99 V.
ACV, 0.1 V resolution is valid from > 100.0 V.
* ACA, 0.001 A resolution is valid from 0.001 A to 1.200 A.
ACA, 0.01 A resolution is valid from > 1.2 A.
* Measuring signals come from the top power plug input
( power source ).
* Auto range.
* ACV, ACA accuracy is test under input signal is sine wave,
50/60 Hz
*ACV, ACA frequency response is from 40 to 400 Hz.
* ACV, ACA is true rms measurement..
* Max. input voltage : AC voltage 250 V, AC current : 10 A.
5

3. FRONT PANEL DESCRIPTION
Fig. 1
3-1 Display
3-2 Backlight button
3-3 Record button ( MAX. / MIN. )
3-4 Data hold button
3-5 Power & function rotary switch
3-6 ACV / DCV & Ωinput terminal
3-7 Load terminal
3-8 Power source terminal
3-9 Battery Cover / Compartment
3-10 Stand
3-11 RS-232 output terminal
3-12 DC 9V power adapter input socket
6

4. MEASURING PROCEDURE
4-1 ACV measurement procedure
1)Rotate the function switch to the " ACV " position and
Power ON the meter.
2)Connect Red test lead to the " V Ω" input terminal and
Black test lead to " COM " input terminal.
3)Use the test lead measurement unknown AC voltage.
4)Read the Display. The show value will correspond to the
position selected. If the Display shows " ---- ", it
indicates an out-of-range measurement.
4-2 DCV measurement procedure
1)Rotate the function switch to the " DCV " position and
Power ON the meter.
2)Connect Red test lead to the " V Ω" input terminal and
Black test lead to " COM " input terminal .
3)Use the test lead measurement unknown DC voltage.
4)Read the display . The show value will correspond to the
position selected. If the Display shows " ---- " it
indicates an out-of-range measurement.
Remark :
* Observe polarity when measuring DC voltage.
4-3 Resistance measurement procedure
1)Rotate the function switch to the Ωposition and Power
ON the meter.
2)Connect red test lead to the " V Ω" input terminal and
black test lead to " COM " input terminal .
Connect test lead to the resistance.
7
Tabla de contenidos
Otros manuales de Multímetro de MRC
Manuales populares de Multímetro de otras marcas

Gossen MetraWatt
Gossen MetraWatt METRAmax 6 Manual de usuario

PeakTech
PeakTech 4000 Manual de uso y cuidado

YOKOGAWA
YOKOGAWA 90050B Manual de usuario

Gossen MetraWatt
Gossen MetraWatt METRALINE DMM16 Manual de usuario

Fluke
Fluke 8846A Manual de operación y mantenimiento

Tempo Communications
Tempo Communications MM200 Manual de usuario