Page 4 XG0526-151109.2
I-Series Indoor Gas Fireplace
Installation
Introduction
Congratulations on your purchase of a Montigo Fireplace.
With over 30 years of experience, Montigo is committed to providing
you with a gas replace that is not only a beautiful addition to your
space, but that is also designed and manufactured to the highest
safety, reliability and engineering standards.
We strongly encourage you to read and carefully follow the instructions
laid out in this Installation, Operation and Maintenance Manual
and retain it for your future reference. Pay special attention to all
cautions, warnings, and notices throughout this manual intended
to ensure your safety.
This manual covers installation, operation and maintenance. Lighting,
operation and care of this replace can be easily performed by the
homeowner. All installation and service work should be performed
by a qualied or licensed installer, plumber or gas tter as certied
by the state, province, region or governing body where the replace
is being installed.
This installation, operation and maintenance manual is applicable
to the models described below. Refer to your rating plate to verify
included options.
Warranty and Installation Information: (See Appendix B)
The Montigo warranty will be voided by, and Montigo disclaims any
responsibility for, the following actions:
► Modication of the replace and/or components including
Direct-Vent assembly or glass doors.
►
Use of any component part not manufactured or approved
by Montigo in combination with this Montigo replace system.
► Installation other than as instructed in this manual.
ConsultyourlocalGasInspectionBranchoninstallationrequirements
for factory-built gas replaces. Installation & repairs should be done
by a qualied contractor.
This appliance is equipped for altitudes from 0 - 4500 feet [0
-1370 m]. For higher altitudes contact your Montigo dealer.
34FIDN-L-F [NG] 34FIDL-L-F [LP]
Part Number 34FIDNIL-01 34FIDLIL-01
Input Rating 31,000 BTU 30,000 BTU
Gas Supply Pressure 7" WC 11" WC
Manifold Pressure
High 3.5" 10"
Low 2.2" 6.4"
Orice Size (DMS) 35 52
Pilot Orice Size (No.) 62 35
Air Shutter Min Settings Fully Closed 3/16" Open
Electrical Requirement 115 VAC, 60Hz 115 VAC, 60Hz
Vent Size 4"Exhaust/3" Intake 4"Exhaust/3"Intake Aluminum / Stainless Flex
Minimum Vent Length 10' 10'
Maximum Vent Length 36' 36'
Efciency AFUE Method 70.01% 71.06%
Efciency P.4 Method 77.40% 78.50%
Clearances
Mantel 17" 17"
Hearth 0" 0"
Side Wall 8" 8"
Control Type SIT Proame 2 SIT Proame 2
Light Bulb Specication 20W, G6.35, Qty 5 20W, G6.35, Qty 5
Fuse Specication 3.15Amps 3.15Amps
Fan Amperage 1.6Amps 1.6Amps
Certication(s) Ansi Z21.88-2014 / CSA 2.33-2014 VENTED GAS FIREPLACE HEATERS
CGA2.17-M91 [R2009] GAS FIREDAPPLIANCES FOR HIGHALTITUDES
CSA P.4.1-09 Fireplace Efciency
CSA P.4.1-09 [R2014] Fireplace Efciency