MONTAGUE Grizzly G Series Manual de usuario

INSTRUCTION MANUAL
THE MONTAGUE COMPANY
1830 Stearman Avenue P.O. BOX 4954
HAYWARD,CA 94540-4954
TEL: 510/785-8822 FAX: 510/785-3342
MONTAGUE
MODELS:
G, GC, GM Series
(25,000 BTU/HR Open Top Burners)
Keep area around appliances free and clear from combustibles.
PLEASE RETAIN THIS MANUAL
FOR FUTURE REFERENCE.
These instructions should be read thoroughly before attempting installation.
Set up and installation should be performed by qualified installation personnel.
Gas Fired Restaurant Ranges

2
IMPORTANT
WARNING:
Improper installation, adjustment,
alteration, service or maintenance
can cause property damage, injury
or death. Read the operating
and maintenance instructions
thoroughly before installing or
servicing this equipment.
FOR YOUR SAFETY:
Do not store or use gasoline or
other flammable vapors and
liquids in the vicinity of this or
any other appliance.
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS MUST BE
POSTED IN A PROMINENT LOCATION. THIS INFORMATION MAY BE OBTAINED BY
CONSULTING THE LOCAL GAS SUPPLIER.
SHIPPING DAMAGE CLAIM PROCEDURE
For your protection, please note that equipment in this shipment was carefully inspected
and packed by skilled personnel before leaving the factory. The transportation company
assumes full responsibility for safe delivery upon acceptance of this shipment.
If shipment arrives damaged:
1. VISIBLE LOSS OR DAMAGE—Be certain this is noted on freight bill or express receipt,
and signed by person making delivery.
2. FILE CLAIM FOR DAMAGES IMMEDIATELY—Regardless of the extent of damage.
3. CONCEALED LOSS OR DAMAGE—If damage is unnoticed until merchandise is un-
packed, notify transportation company or carrier immediately, and file ―concealed dam-
age‖ claim with them. This should be done within fifteen (15) days of date that delivery
was made to you. Be sure to retain container for inspection.
We cannot assume responsibility for damage incurred in transit. We will, however, be glad
to furnish you with necessary documents to support your claim.
CONTENTS
INSTALLATION ………. 3 MAINTENANCE ………. 12
OPERATION …………..10 SERVICE ………………..15
RENEWAL PARTS ……..23

3
INSTALLATION
The Montague Grizzly gas oven ranges are manufactured for use with the type of gas indicated on
the name plate.
The Montague Grizzly gas convection oven type ranges are produced with the best possible
material and workmanship. PROPER INSTALLATION IS ESSENTIAL FOR SAFE AND EFFICIENT
TROUBLE-FREE OPERATION.
Qualified installation personnel are individuals, a firm, corporation, or company which in person, or
through a representative are engages in, and are responsible for:
A. The installation or replacement of gas piping or the connection, installation, repair, or servicing
of equipment, who is experienced in such work, familiar with all precautions required, and has
complied with all requirements of stats or local authorities having jurisdiction. Reference:
National Fuel Gas Code Z223.1, Section 1.4.
B. The installation of electrical wiring from the electric meter, main control box, or service outlet to
the electric appliance. qualified installation personnel must be experienced in such work, be
familiar with all precautions required, and have complied with all requirements of state and local
authorities having jurisdiction. Reference: National Electric Code, NFPA No. 70.
THE INSTALLATION INSTRUCTIONS CONTAINED HEREIN ARE FOR THE USE OF
QUALIFIED INSTALLATION AND SERVCE PERSONNEL ONLY. INSTALLATION OR
SERVICE BY OTHER THAN QUALIFIED PERSONNEL MAY RESULT IN DAMAGE TO THE
OVEN AND/OR INJURY TO THE OPERATOR.
READ CAREFULLY AND FOLLOW THESE INSTRUCTIONS
THE RANGE(S) MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, OR IN
THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL FUEL GAS CODE, ANSI
Z223.1, NATURAL GAS INSTALLATION CODE, CAN/CGA-B149.1, OR THE PROPANE
INSTALLATION CODE, CAN/CGA-B149.2, AS APPLICABLE, INCLUDING:
1. The appliance and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of
1/2 psig. (3.45 kPa)
2. The appliance must be isolated from the gas supply piping system by closing its individu-
al manual shutoff valve during any pressure testing of the gas supply piping system at
test pressure equal to or less than 1/2 psig. (3.45 kPa)

4
INSTALLATION
PROVISIONS MUST BE MADE FOR ADEQUATE AIR SUPPLY TO THE UNIT.
THE UNIT, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN
ACCORDANCE WITH LOCAL CODES, OR IN ABSENCE OF LOCAL CODES, WITH THE
NATIONAL ELECTRICAL CODE, ANSI/NFPA 70, OR THE CANADIAN
ELECTRICAL CODE, CSA C22.2, AS APPLICABLE.
Ventilating Hood
The range(s) must be installed under a properly designed ventilating hood. The hood should
extend at least 6‖ beyond all sides of the unit. The hood should be connected to an adequate
mechanical exhaust system.
Information on the construction and installation of ventilating hoods may be obtained from the
‗Standard for the Installation of Equipment for the Removal of Smoke and Grease Laden Vapors
from Commercial Cooking Equipment‖, NFPA 96, available from the National Fire Protection
Association, Batterymarch Park, Quincy, MA 02269.
It is also necessary that sufficient room air ingress be allowed to compensate for the amount of
air removed by the ventilating system. Otherwise, a subnormal atmospheric pressure will occur
which may interfere with burner performance or may extinguish the pilot flame. In case of unsat-
isfactory range performance, check with the exhaust fan in the ―OFF‖ position.
Clearances
Adequate clearance must be provided at the side, back, and in the aisle to allow the doors to
open sufficiently to permit the removal of the racks and for serviceability. Adequate clearance for
air openings into the combustion chamber must be provided.
CLEARANCES
COMBUSTIBLE NONCOMBUSTIBLE
CONSTRUCTION CONSTRUCTION
Back 2” (5.1cm) 2” (5.1cm)
Left & Right Side 11”(27.9cm) 2” (5.1cm)
6” (15.2cm) HIGH LEGS: SUITABLE FOR INSTALLATION ON COMBUSTIBLE FLOORS.
WITHOUT LEGS: FOR USE ONLY ON NONCOMBUSTIBLE FLOORS.
CAUTION
DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION AIR. KEEP THE
APPLIANCE AREA FREE AND CLEAR FROM COMBUSTIBLES

5
INSTALLATION
DO NOT LIFT RANGE BY THE FRONT RAIL.
ASSEMBLY
Uncrate range as near to final location as possible. Remove all shipping wire from burners and all
packing material and accessories from oven interior.
Then assemble as follows:
Floor Mounted Range:
1. Screw the adjustable feet of the legs in all the way. Then tightly screw the complete leg
assembly into mounting holes at each corner of the range. If the unit is intended for curb
installation, no legs are provided. The curb must be noncombustible material.
2. Install door handle and secure with screws that are provided. See diagram for correct
orientation.
3. Lift high shelf above the range and slide channels into position. Secure to range back with
screws that are provided.
IF RANGE IS EQUIPPED WITH A FRYTOP SECTION, REMOVE WOOD SHIPPING
STRIPS LOCATED BELOW THE GREASE TROUGH.

6
INSTALLATION
Cabinet or Skeleton Ranges:
Follow above instructions.
Modular Ranges:
Assemble modular base and set in place. Adjust feet as explained above.
Counter Ranges:
Set unit in desired position and secure to counter using holes provided at rear and bracket
at front.
All Ranges:
1. Install Open Top and Hot Top sections as shown in diagram below. Install burner bowls and
grates on Open Top section.
2. Install top burner valve handles, and thermostat knob(s). If top burner valve handles fit loose
on valve shaft, spread slot on end of shaft slightly with screwdriver blade so that handle will fit
snug.
3. When range is in permanent position, level unit by placing carpenter‘s level on oven bottom
and level from front to back and side to side.
Adjust as follows:
FLOOR INSTALLATION ON LEGS: Adjust by turning the foot of the adjustable leg. Make sure the
leg does not turn.
COUNTER OR CURB INSTALLATION: Level range from front to rear and side to side using a
carpenter‘s level. Place shim under low side.
INSTALLATION

7
INSTALLATION
Fry Top Ranges
Leveling bolts are at the rear of the range under the Fry Top plate.
Adjust leveling bolts so that the plate is pitched to the front to provide
for grease runoff. Be sure wooden strips have been removed from
below the grease trough.
GAS PRESSURE REGULATOR
GAS CONNECTION
Before connecting the range to the gas supply line, be sure that all new piping has been
cleaned and purged to prevent any foreign matter from being carried into the controls by the gas. In
some cases, filters or drops are recommended. A separate Gas Shut Off Valve must be installed
upstream from the gas pressure regulator adjacent to the range and be located in an accessible
area.
It is important that adequately sized piping be run directly to the point of connection at the
range, with as few elbows and tees as possible. Consult local gas company for proper piping size
and gas pressure.
THIS RANGE IS DESIGNED FOR USE WITH A GAS PRESSURE REGULATOR. THE
REGULATOR SUPPLIED WITH THIS UNIT MUST BE USED.
FOR NATURAL GAS: This gas pressure regulator is factory adjusted for 6.0‖ W.C.
manifold pressure. The rated inlet pressure to the regulator is 1/2psig (3.45kPa).
FOR PROPANE GAS: This gas pressure regulator is factory adjusted for 10.0‖ W.C.
manifold pressure. The rated inlet pressure to the regulator is 1/2 psig (3.45kPa).
Unless otherwise specified, the range is equipped with fixed orifices for use with a
manifold pressure of 6.0” water column for natural gas and 10.0” water column for
propane gas.

8
INSTALLATION
PIPE JOINT COMPOUND OR THREAD SEALANT THAT IS USED
SHOULD BE RESISTANT TO ACTION OF LIQUEFIED PETROLEUM
GASES.
Install the gas pressure regulator with gas flowing as indicated by the arrow on the
regulator. Use pipe compound or thread sealant and carefully thread regulator to pipe so that
there is no cross-threading, etc, which could cause leakage.
Apply wrench only to the flat areas around the pipe tapping at the end being threaded to
the pipe to avoid possible damage to the regulator body which could result in leakage.
Connect the gas supply line from the Service Gas Shut Off valve to the inlet side of the gas
pressure regulators using 3/4‖ pipe. If flexible or semi-flexible connectors are used, an AGA listed
flexible connector with an I.D. equal to 3/4‖ pipe must be used. DO NOT USE A DOMESTIC
APPLIANCE TYPE GAS FLEXIBLE CONNECTOR. Avoid kinks or sharp bends that could restrict
gas flow.
Turn Gas Shut Off Valve ―ON‖ and immediately check carefully for gas leaks. Do this
before attempting to operate the range.
TEST ALL PIPE JOINTS FOR LEAKS BEFORE OPERATING RANGE. THIS INCLUDES
ALL GAS CONNECTIONS THAT MAY HAVE LOOSENED DURING SHIPMENT. USE A
RICH SOAP SOLUTION (OR OTHER ACCEPTED LEAK TESTER) AROUND ALL PIPE
CONNECTIONS AND ALL OTHER JOINTS. DO NOT USE AN OPEN FLAME.
ABSOLUTELY NO LEAKAGE SHOULD OCCUR, OTHERWISE THERE IS A DANGER OF
FIRE OR EXPLOSION DEPENDING UPON CONDITIONS. NEVER USE IF LEAKAGE IS
DETECTED.

9
PILOT ADJUSTMENT—TOP BURNERS
OVEN TOP: The front and rear pilots are controlled by one valve. To adjust pilot, turn ad-
justing screw counterclockwise to increase or clockwise to decrease pilot flame. Adjust flame to a
point where only a trace of yellow tip remains.
FRY TOP and HOT TOP: Each pilot is controlled by a pilot valve. Turn adjusting screw until
pilot flame is 1/2‖ high.
BURNER ADJUSTMENT
The efficiency of the range depends on a delicate balance between the supply of air and
the volume of gas so that complete combustion is achieved. Whenever this balance is disturbed,
poor operating characteristics occur.
The air supply is controlled by an air shutter on the front of the burner. The air shutter
openings should be increased until the flame on the burner begins to ―lift‖. The air shutter should
then be closed slightly and locked in place. A yellow streaming flame indicated insufficient air. This
condition can be corrected by increasing the air shutter opening.
FRY TOP AND OVEN THERMOSTATS
The by-pass (minimum burner flame) has been adjusted at the factory and should require
no further adjustment.
THE BY-PASS FLAME MUST BE RECHECKED WHEN PERFORMING CHECKOUT OF
RANGE PRIOR TO PLACING EQUIPMENT IN SERVICE. THE BY-PASS MUST BE SET
CAREFULLY AND ACCURATELY. REFER TO SERVICE SECTION OF THIS MANUAL
FOR PROPER PROCEDURE.
INSTALLATIONINSTALLATION

10
OPERATION
OPERATING INFORMATION FOR THE RANGE HAS BEEN PREPARED FOR USE
BY QUALIFIED AND/OR PROFESSIONAL OPERATING PERSONNEL.
CAUTION
DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION AIR. KEEP
THE APPLIANCE AREA FREE AND CLEAR FROM COMBUSTIBLES.
IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN
SHUT OFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS
SUPPLIER FOR SERVICE.
GAS CONTROLS
Top Burners— Open Top, Hot Top and Manual Fry Top
Check that pilots are burning. Then rotate valve handles counterclockwise to full on, burner will
ignite automatically. Adjust flame height as desired. To shut down, rotate valve handle clockwise
to ―OFF‖ position.
Fry Top– Thermostat Controlled
Check that the pilot(s) are burning. Then push thermostat dial inward and rotate dial counter-
clockwise to maximum thermostat setting, burner(s) will ignite automatically. After ignition, turn
thermostat dial to desired setting. To shut down, rotate thermostat dial clockwise to ―OFF‖
position.
OVEN
A. Lighting
Turn thermostat knob to ―OFF‖ position and wait five (5) minutes.
1. Remove burner compartment cover and open pilot access door.
2. Locate the Piezo Igniter in front of the pilot access door.
3. Press and hold red button in (Safety Pilot Valve) and repeatedly depress the button on the
Piezo Igniter until the pilot burner ignites.
4. After pilot burner ignites, continue to hold red button depressed for 30 to 45 seconds or until
pilot remain burning when button is released. If pilot goes out, repeat process.
5. If the pilot burner is unable to be lit with the Piezo Igniter, apply a lighted match to the pilot
burner.
6. Close pilot access door and replace burner panel.
OPERATION
Otros manuales para Grizzly G Series
1
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Rango de MONTAGUE

MONTAGUE
MONTAGUE Legend V136 series Manual de usuario

MONTAGUE
MONTAGUE LEGEND C12 Manual de usuario

MONTAGUE
MONTAGUE RB Series Manual de usuario

MONTAGUE
MONTAGUE Legend 12 Series Manual de usuario

MONTAGUE
MONTAGUE LEGEND C12 Manual de usuario

MONTAGUE
MONTAGUE Grizzly G Series Manual de usuario

MONTAGUE
MONTAGUE Legend 12 Manual de usuario