Mini-Circuits HPA-272+ Manual de usuario

HPA-272+
Rack Mounted High-Power Amplifier (100W)
700 to 2700 MHz
User’s Manual
AN-60-086 Rev.: A (M155654) 03/23/16 File: AN60086.doc
©Mini-Circuits, 2016. All rights reserved.
1

Important Notice
This guide is owned by Mini-Circuits and is protected by copyright, trademark and other intellectual
property laws.
The information in this guide is provided by Mini-Circuits as an accommodation to our customers and may
be used only to promote and accompany the purchase of Mini-Circuits’ Parts. This guide may not be
reproduced, modified, distributed, published, stored in an electronic database, or transmitted and the
information contained herein may not be exploited in any form or by any means, electronic, mechanical
recording or otherwise, without prior written permission from Mini-Circuits.
This guide is subject to change, qualifications, variations, adjustments or modifications without notice and
may contain errors, omissions, inaccuracies, mistakes or deficiencies. Mini-Circuits assumes no
responsibility for, and will have no liability on account of, any of the foregoing. Accordingly, this guide
should be used as a guideline only.
Trademarks
All trademarks cited within this guide are the property of their respective owners. Neither Mini-Circuits nor
the Mini-Circuits HPA-272+ are affiliated with or endorsed or sponsored by the owners of those
trademarks.
Mini-Circuits and the Mini-Circuits logo are registered trademarks of Scientific Components Corporation.
Mini-Circuits
13 Neptune Avenue
Brooklyn, NY 11235
Phone: 1-718-934-4500
Email: sales@minicircuits.com
Web: www.minicircuits.com
Version 3/23/16
© Mini-Circuits, 2016. All rights reserved.
AN-60-086 Rev.: A (M155654) 03/23/16 File: AN60086.doc
©Mini-Circuits, 2016. All rights reserved.
2

CONTENTS
1INTRODUCTION ................................................................................................................... 4
2WARNINGS........................................................................................................................... 5
2.1 Safety Hazards............................................................................................................... 5
2.2 Additional Precautions.................................................................................................... 6
3PHYSICAL DESCRIPTION.................................................................................................... 7
4FUNCTIONAL DESCRIPTION............................................................................................... 8
5POWER SPECIFICATIONS AND MAXIMUM RATINGS........................................................ 9
5.1 DC Power Specifications ................................................................................................ 9
5.2 Maximum Ratings........................................................................................................... 9
6UNPACKING ........................................................................................................................10
6.1 Unpacking .....................................................................................................................10
6.2 Package Contents .........................................................................................................10
7LAYOUT AND INSTALLATION.............................................................................................11
7.1 Rack Mounting ..............................................................................................................11
7.2 Rear Panel Grounding Terminal ....................................................................................11
8OPERATING INSTRUCTIONS .............................................................................................12
8.1 Connecting the Amplifier ...............................................................................................12
8.2 Temperature and Fan Monitoring ..................................................................................12
8.2.1 Front Panel LED Indicators .................................................................................12
8.2.2 Status Monitoring Via the 9-Pin D-Sub Connector ...............................................13
9COMPANION PRODUCTS AND APPLICATION CIRCUITS ................................................14
9.1 High Power, Multi-Channel Burn-In System...................................................................14
9.2 Output Power Monitoring ...............................................................................................15
9.3 Output Power Monitoring with Gain Control ...................................................................16
9.4 High Reliability Test Cables...........................................................................................17
9.5 HandFlex®Interconnect Cables .....................................................................................17
RETURN MATERIAL AUTHORIZATION (RMA) .......................................................................18
AN-60-086 Rev.: A (M155654) 03/23/16 File: AN60086.doc
©Mini-Circuits, 2016. All rights reserved.
3

1 INTRODUCTION
Thank you for choosing Mini-Circuits’ HPA-272+ high power amplifier to meet your needs! The
purpose of the this user’s manual is to instruct you on basic installation and setup of your
equipment, to advise you on general precautions to be taken when installing and handling the
amplifier unit, and to provide basic information on the proper use of this equipment.
We’re here to support you every step of the way. For technical support and assistance, please
find the following points of contact for your convenience:
Chi Man Shum
Phone: +1 201 647-1615
Email: chiman@minicircuits.com
chimanshum@gmail.com
AN-60-086 Rev.: A (M155654) 03/23/16 File: AN60086.doc
©Mini-Circuits, 2016. All rights reserved.
4

2 WARNINGS
Mini-Circuits’ HPA-272+ is designed with multiple levels of protection to prevent injury to the
user and damage to the amplifier during operation. However, Mini-Circuits strongly
recommends that you observe standard operating precautions for high-power RF amplifiers to
reduce the risk of injury and damage to the amplifier and connected components.
2.1 Safety Hazards
Electrical Danger
This equipment contains live 85-265V contacts and should be
used and handled only by qualified professionals. When
performing any activity in and around the HPA-272+ case,
please exercise extreme caution to avoid touching any parts
where live voltage may be present to prevent injury or death
due to electrical shock.
Heavy Object
The equipment case for your HPA-272+ unit is heavy. When
handling, use caution to prevent damage to the equipment
and injury. Always follow safe lifting protocols and use any
necessary lifting aids to prevent muscle strain or back injury.
The unit must be supported in a rack structure by securely
fastened side rails or shelving.
High Speed Fan
Blade
The HPA-272+ contains cooling fans with rotating blades
that can cause serious injury or cut. Remove any loose
articles before working inside the HPA-272+ chassis to
avoid getting caught in moving machinery.
30 lbs. (13.61 Kg)
AN-60-086 Rev.: A (M155654) 03/23/16 File: AN60086.doc
©Mini-Circuits, 2016. All rights reserved.
5

2.2 Additional Precautions
Maximum Input Power
:
The HPA-272+ has a maximum RF input power rating of
+7dBm. Exceeding this maximum will likely cause permanent damage to the amplifier.
Power Supply:
Do not apply RF input signal to the HPA-272+ while the AC mains supply
is disconnected or the amplifier is powered off from the front panel switch. Use only the supplied
AC mains power supply lead for connection to a properly grounded 85-265V mains power
socket.
Air Flow:
The equipment chassis must be mounted by the customer to maintain a
minimum of 1U (1.75”) free air space above and below the top and bottom panels with
unobstructed access to room ambient airflow for proper operation.
Electrostatic Discharge:
Any person operating this unit must have Electrostatic Discharge
(ESD) protection to prevent damage to any components.
Opening & Tampering:
This equipment is designed to be serviced only by professional
electrical technicians. Case openings by any person other than qualified personnel authorized by
Mini-Circuits or the customer will void any and all terms of the Limited Warranty.1
1Although top and bottom panels are intended to allow accessibility, it is important to use caution when connecting or
disconnecting any electrical or RF connection, or when moving, removing, or replacing any wires, cables, connections, or
components within the chassis to avoid potentially damaging or dislodging any other cables or connections.
AN-60-086 Rev.: A (M155654) 03/23/16 File: AN60086.doc
©Mini-Circuits, 2016. All rights reserved.
6

3 PHYSICAL DESCRIPTION
Mini-Circuits’ HPA-272+ high power amplifier comes housed in an aluminum alloy chassis
measuring 19” wide x 5.20” (3U) high x 20” deep (482 x 132 x 508mm). The front panel is fitted
with an AC power on/off switch, N-Type connectors at the RF input and output ports, a standard
9-pin D-sub socket (see
section 8.2.2
Status Monitoring Via the 9-Pin D-Sub Connector), and 3
LED lights indicating AC power connection (green), temperature alarm (red), and fan
malfunction alarm (red). The front panel of the unit is also equipped with two handles and
marking with the name, model number, frequency range, and saturated output power of unit.
Slotted holes on the outer left and right extensions of the front panel allow secure mounting to a
standard 19” (483mm) rack support structure.
Figure 1: Front panel of HPA-272+ equipment chassis
On the rear panel of the unit is the input for a standard 85-265V AC power supply with caution
label (right side). At the right of the rear panel is a clearly marked grounding terminal. It is
recommended that this terminal be connected to a Common Bonding Network (CBN). On the
left side of the rear panel is an identification sticker containing the model name and serial
number. Two cooling fans are mounted to the center of the panel.
Figure 2: Rear panel of HPA-272+ equipment chassis
AN-60-086 Rev.: A (M155654) 03/23/16 File: AN60086.doc
©Mini-Circuits, 2016. All rights reserved.
7

4 FUNCTIONAL DESCRIPTION
Mini-Circuits’ HPA-272+ is a high-power rack-mountable RF amplifier capable of delivering
output power up to 100W across the 700 to 2700 MHz frequency range. The amplifier provides
48 dB gain with ±1.7 dB gain flatness, +55 dBm OIP3 and 89 dB reverse isolation. It operates
on a self-contained 85 – 265V AC line power supply. This model features internal cooling and
self-protection against over-temperature, and is immune to open and short loads while
delivering full power from the output port.
The unit features LED indicators on the front panel which illuminate to alert the user when AC
power is connected, when the unit temperature exceeds the maximum rating, and when the
cooling fans are not functioning properly. The 9-Pin D-Sub socket allows remote monitoring of
these conditions in layouts where the front panel is not clearly visible to the operator.
The HPA-272+ is an ideal solution for test applications requiring high power over a wide
frequency range such as EMI and antenna testing, RF power stress testing, reliability testing
and more. It is also highly useful for production test applications in which it is desirable to test
many DUTs in parallel such as HTOL. The amplifier can be paired with high power splitters to
distribute a test signal through up to 80 channels.See
section 9
for more information about
applications of this equipment.
AN-60-086 Rev.: A (M155654) 03/23/16 File: AN60086.doc
©Mini-Circuits, 2016. All rights reserved.
8

5 POWER SPECIFICATIONS AND MAXIMUM RATINGS
5.1 AC Power Specifications
Parameter
Specification
Supply Voltage:
~Line
85-265V : 47-63 Hz
Power Consumption
531W (typ.)
5.2 Maximum Ratings
To prevent damage to your equipment, please do not exceed any of the maximum ratings
specified here and on the model data sheet.
Table 1: Maximum
Parameter
Ratings
Operating Temperature
0˚C to 50˚C
Storage Temperature
-20˚C to 70˚C (non-condensing)
Input RF Power
(no damage) +7 dBm
AN-60-086 Rev.: A (M155654) 03/23/16 File: AN60086.doc
©Mini-Circuits, 2016. All rights reserved.
9

6 UNPACKING
6.1 Unpacking
The equipment ships in a single large cardboard carton measuring 11 x 25.125 x 23” pictured in
the figure below.
Figure 5: Shipping carton
Within the carton, the HPA-272+ unit is protected by pink foam inserts. Remove the unit from
the box carefully and set on a stable surface. Be sure not to lose or misplace the power cord
contained in the package with the amplifier unit.
6.2 Package Contents
Table 2: Package contents
Item Description
Quantity
HPA-272+ Unit
1
CBL-3W-XX+ Black AC Power Cord (US, EU or UK)
1
Caution: The package and its contents are heavy! Use safe lifting protocols when
handling to avoid strain or injury.
A: 11”
B: 25.125”
C: 23”
AN-60-086 Rev.: A (M155654) 03/23/16 File: AN60086.doc
©Mini-Circuits, 2016. All rights reserved.
10
Tabla de contenidos