DA-100 Installation Manual page 4
EASY Installation continued...
8. Changing Chime Selection: To select an alert chime sound in the Control Panel manual mode, move the tone-select switch to one of the three available
tones. No. 1 position is a “ding-dong”, No. 2 position is a “ding-ding-ding” and the No. 3 position is a “dong-ding-dong” alert. (See Figure 2)
9. Zoning Set-Up: To utilize the Zone features, remove the two (2) screws from the chassis, pull o the cover, and locate the JP3 Jumper-Header on the
Zoning Pin, and pull the Jumper-Header o (see #9 on Figure 3 below). Then replace the cover on the enclosure. In the Zone Mode the receiver will
provide a dierent tone for up to (3) dierent transmitters monitoring (3) dierent driveways. Additional DA-611TO or DA-610TO Sensor/Transmitters will be
needed for each additional zone to be monitored (see Figure 4).NOTE: The tone-select switch is disabled in the zone mode: the tone select is automatic.
10. Equipment Addressing: The Control Panel AND the Sensor/Transmitter are already set for the default address mode from the factory, with NO Jumper-
Headers on the address pins. IN THE RARE CASE of a neighbor’s system interfering with your system, use the Jumper-Headers to select dierent
address pins for your system. Make certain they are the same in BOTH your Control Panel AND Sensor/Transmitter. You can place a Jumper-Header on
one set of pins, or the other, or on both sets of pins depending on how many other system addresses are nearby. (see #10 on Figure 3 below)
Free Lifetime Technical Support
FIGURE 3
Electrical Board inside the DA-100CP
10.) Photo of Default addressing above
shows NO Jumper-Header on the Address
pins. Change address by adding a Jumper-
Header on either set of address pins.
9.) Photo of Default Single Zone shows a
Jumper-Header on the Zoning pin. Activate
Zoning Mode by removing this Jumper-
Header from the Zoning pin.
FIGURE 2
Alert Chime Tone Selection Switch
AA
A
B
B
B
B
FIGURE 4
Example of a farm with Zoning activated
A) Three (3) zones monitored with sensor/transmitters. These can be either DA-611TOs or DA-610TOs.
B) Four DA-100CP Control Panel/Receivers with alerts placed in the home, in the work shed, and in two barns.
In this installation, the owners are alerted to vehicles
approaching in any of the three driveways by the sensors placed
in areas marked “A”, with dierent alert chime tones for each so
the owners know exactly which drive the vehicle is in, and those
alerts are communicated in four dierent buildings where control
panels are mounted marked “B”.
Mier Products oers the FREE service of using satellite imaging
like the photo shown, and talking with the installer to determine
which equipment needs to be installed in each location to satisfy
the customer’s need. Just give us a call!
Jumper-Header shown here: