Earth1006
Operation Manual

I
CONTENTS
1 Introduction..........................................................................................................1
1.1 Brief introduction.....................................................................................1
1.2 Features....................................................................................................1
1.3 Basic parameters....................................................................................2
1.4 Outline dimension(Unit: mm)............................................................... 4
1.5 Panel structure........................................................................................ 4
1.6 Display...................................................................................................... 5
1.7 Key instruction.........................................................................................5
1.8 Interface....................................................................................................5
1.9 Application topology............................................................................... 6
1.10 Unpacking.............................................................................................. 7
1.11 Boot operation....................................................................................... 7
2 Detailed parameters..........................................................................................8
2.1 Power supply........................................................................................... 8
2.2 Display instruction.................................................................................. 9
2.3 Network mode....................................................................................... 11
2.4 Interface definition................................................................................12
2.4.1 Power interface......................................................................... 12
2.4.2 AI interface................................................................................. 14
2.4.3 DI/PI interface............................................................................ 15
2.4.4 RS485 communication interface........................................... 16
2.4.5 Camera interface...................................................................... 19

II
3 Device configurations..................................................................................... 19
3.1 configuration tool.................................................................................. 19
3.2 Local configuration method................................................................20
3.3 Remote configuration method........................................................... 21
3.4 Configuration options.......................................................................... 21
4 Installation instruction..................................................................................... 29
4.1 Installation tool...................................................................................... 29
4.2 Installation method, dimension and instruction............................. 29
4.2.1 Installation method................................................................... 29
4.2.2 Installation instruction.............................................................. 29
4.2.3 Installation dimension.............................................................. 30
4.3 SIM card installation............................................................................ 30
4.4 Device battery replacement............................................................... 32
4.5 Fixture..................................................................................................... 33
4.5.1 Underground installation examples...................................... 33
4.5.2 wall-mounting type....................................................................35
4.5.3 hoop-mounting type................................................................. 36
4.5.4 solar mounting type.................................................................. 37
5 Data platform instruction................................................................................ 38
6 FAQ.....................................................................................................................38
7 Responsibility................................................................................................... 41

III
Our company keeps the product technology and craftwork’s modification
rights. If the information were changed, no more notice would be edited.
Please pay attention to the latest introduction.
Our company keeps the final power of interpretation for this operation
menu.

1
Thank you for choosing the products from Micro Sensor Co., Ltd.
To better use this product, please read this operation manual
carefully before using.
1 Introduction
1.1 Brief introduction
Earth1006 Remote Monitoring Terminal is a compact device with battery
supply, ultra-low power consumption, IP68 protection, wireless
communication and various sensor data collection function, in specific
circumstance, multiple power supply options are available. It is suitable
for the monitoring fields without power supply condition and the harsh
environment. It could realize the multi-function including data collection,
storage, alarming and transmission for underground water, firefighting
water, dam water, water supply and drainage pipeline.
With a wide coverage of wireless network, the product could detect the
real-time data of many monitoring sites in a wide range of areas like
tap-water pipeline pressure, flow, underground water, agricultural
irrigation, dam level, water monitoring, wind, rain, ambient temperature
and humidity, air quality monitoring, water flow monitoring, image and
firefighting pipeline monitoring, especially suitable for Underground Well
detection application in a harsh environment.
1.2 Features
•IP68 protection--dust-proof and water-proof
•Variety of power supply optional and with ultra-low power

2
consumption
•Integrated battery with 3~5 years’ lifespan
•Wireless transmission, no field wiring
•Multi-parameter including pressure, temperature, level, flow, image
and manhole cover motoring
•Multi-channel with max. 8-way sensor access
•Remote configuration for collection, transmission and image
interval
•Remote configuration for upper and lower alarm limit and web
real-time warning
•PC and mobile terminal data application
•Support customer self-built system and configuration application
•Equipped with installation accessories
•Solution for underground pipe-network and pipe rack
1.3 Basic parameters
Power supply
Mode: battery/solar power/12~28V DC/110~240V AC
Consumption: sleeping current ≤30uA@14.4V
Transmission average current ≤40mA@14.4V
Interface
Interface type: 3-way AI, 2-way DI/PI,1-way RS485,1-way Camera
Data transmission
Communication mode: 2G/Multi-Bands/NB-Iota/LoRa

3
Wake-up mode: magnetic activation/timing/alarm wake-up
Sampling interval: 1,5,10,30,60,360,720,1440 minutes optional,
alarms are given at the intervals, and maximum 3 times warning can
be sent over each interval to ensure longer battery life.
Transmission interval: 1,5,10,30,60,360,720,1440 minutes optional
Image interval: 30,60,720,1440 minutes optional
Upload information: sensor data, battery information, network status,
self-check information
Data storage
Local storage: Flash 4MB (more than 200,000 history data)
Configuration
Configuration mode: local/remote configuration
Display
Segment LCD, with backlight
Environmental condition
Working temperature: -20℃~70℃
Storage temperature: -40℃~85℃
Others
Protection: IP68 (work normally for 72 hours at 1m below the water)
Housing material: PA6+30%GF
Installation method: wall-mounting, hoop-mounting
Outline dimension: 147×262.5×105.5mm

4
Weight: about 2.3kg
Accessory: magnetic bar*1, fixed support*1, M5 bolt*1, ф8mm
expansion bolt*3, ф200mm hoop *2
1.4 Outline dimension(Unit: mm)
1.5 Panel structure
Note:
1-mounting hole
2-magnetic control key
3-display screen
4-fool-proof interface
5-operation instruction

5
1.6 Display
1.7 Key instruction
Keys need to use the matching magnetic bar to operate, when the
magnetic bar close to or gently click the magnetic control key, Earth1006
Remote Monitoring Terminal will come into the key operation.
Off state (key induces 1s and the screen is not lit), key induces 8s, the
device boot;
Boot state, the key induces 1s, the screen lit;
When the screen is bright, the key induces 1s flip;
When the screen is bright, the key induces 8s off.
1.8 Interface
Table 1.1 Device interface
Type
AI
DI/PI
RS485
Camera
Qty.
3
2
1
1
Signal
0V~5V DC/
4mA~20mA
DC
Switch/pulse
ModBus RTU
Pictures only, video
transmission not
available
┄Device status
┄Channel NO./unit
┄Channel value/alarm

6
Remark
Collection
accuracy
±0.5%FS
Input current
≤30mA
Low level
0V~1V DC
High level
5V~12V DC
Pulse
frequency
≤10Hz
Support
max.3-way
sensor parameter
analysis and also
be used for device
configuration
RS485
1.9 Application topology
Tabla de contenidos