Rev.0 1/2020
4
LIMITED WARRANTY
METRON warrants its product to the original consumer purchaser that it will repair, or replace, any product that is
determined to be defective for the following terms: Two (2) years from date of purchase on all components.
To be eligible for repair or replacement under this warranty, the product in question must be sent back to
METRON within the warranty period and the original consumer purchaser must comply with the following
conditions:
• The product thereof must not have been modified or altered in any way by an unauthorized source.
• The product thereof must have been used in accordance with the user manual.
This limited warranty does not cover:
• Damage due to improper use;
• Accidental or intentional damage;
• Misuse, abuse, corrosion, or neglect;
• Product impaired by severe natural conditions, such as excessive hail storms, lightning strikes,
tornados, flooding, ice or other natural occurrences;
• Damage due to improper packaging on return shipment.
Any and all labor charges for troubleshooting, removal or replacement of the product are not covered by this
warranty and will not be honored by METRON. All shipping costs regarding repair or replacement of the product
is to be pre-paid by the original consumer purchaser.
yes (all parts) yes (all parts)UV resistance
Type 2 (IEC 62196) Female Plug Type 2 (IEC 62196) Female Plug
Schuko – Type F/E, CEE, Type G,
Type H,…
Yes, 30 mA (optionally PC03T
can be supplied without RCD)
1.6 kg (5m cable) + 0.16 kg per
each additional meter of cable
2.3 kg (5m cable) + 0.3 kg per
each additional meter of cable
CEE 32A (3-phase/3P+N+E),
CEE 32A (1-phase/2P+E),…
6/8/10/13/16 A 6/8/10/13/16/20/25/32 A
5m to 12m (or on request) 5m to 12m (or on request)
optional (Schuko only) no
no
yes yes
IP54 (rain water resistant) IP54 (rain water resistant)
from -30°C to +50°C from -30°C to +50°C
TECHNICAL SPECIFICATIONS
EV Side Plug Type
Wall socket/grid side Standard Plug Types
Max. Charging Current 16A (1-phase)
3,7 kW 7,4 kW
32A (1-phase)
Possible charging current settings
Max. Charging Power
Rated Voltage 230 Vac (1-phase) 230 Vac (1-phase)
Operating voltage/frequency range from 90 V to 270 V (50/60 Hz) from 90 V to 270 V (50/60 Hz)
PREMIUM quality polyurethane
compound cable (Made in Germany)
Wall plug integrated OVER-TEMPERATURE
PROTECTION with automatic reset
IP Rating
Operating Ambient Air Temperature Range
Type B ground fault protection device (RCD)
Type A ground fault protection device (RCD)
Weight
PC03T PC04T
no
Yes, 30mA, integrated inside
CEE 32A plug (optionally PC04T
can be supplied without RCD)