megabyte megascan M1 Manual de usuario

megascan M1
User Manual Rev. 1.0 Updated on 28th
August, 2009
(This user manual / product specification is subjected to be changed without prior notice) P.
1
megascan M1 User Manual
Rev. 1.0
Model: megascan M1

megascan M1
User Manual Rev. 1.0 Updated on 28th
August, 2009
(This user manual / product specification is subjected to be changed without prior notice) P.
2
Table of Content
FCC statement.....................................................................................................3
CE statement.......................................................................................................3
Chapter 1 Introduction of megascan M1...........................................................4
1.1
Overview of megascan M1 ................................................................ 4
1.2
Ports Description ................................................................................ 5
1.3
Indicators LEDs in megascan M1 ..................................................... 6
1.4
Antenna for megascan M1 ................................................................ 7
1.5
Product Features ................................................................................ 8
1.6
Specification:....................................................................................... 9
Chapter 2 Installation of megascan M1...........................................................10
2.1
Power up megascan M1 .................................................................. 10
2.2
Environmental Requirements .......................................................... 10
2.3
Start up Procedures ......................................................................... 11
2.4
Caution .............................................................................................. 11
2.5
Professional Installation Instructions .............................................. 12
Chapter 3 Demonstration of RFID Applications .............................................15
3.1
Creating RFID Application with megascan M1.............................. 15
3.1.1
Delivering Application to megascan M1................................... 15
3.1.2
Programming Language compatibility...................................... 15
Chapter 4 Regulatory Information ...................................................................16
4.1
Federal Communications Commission (FCC) Compliance.......... 16
4.1.1
Radio Frequency Radiation Exposure ....................................... 17
4.2
CE Compliance................................................................................. 18
Chapter 5 Disclaimer Notice ............................................................................19
Chapter 6 Warranty...........................................................................................20
Chapter 7 Support.............................................................................................21

megascan M1
User Manual Rev. 1.0 Updated on 28th
August, 2009
(This user manual / product specification is subjected to be changed without prior notice) P.
3
FCC statement
FCC NOTICE:
To comply with FCC part 15 rules in the United States, the system must be professionally
installed to ensure compliance with the Part 15 certification. It is the responsibility of the
operator and professional installer to ensure that only certified systems are deployed in
the United States.
The use of the system in any other combination (such as co-located antennas transmitting
the same information) is expressly forbidden.
CE statement
CE NOTICE:
The CE Mark applies to products regulated by certain European health, safety and
environmental protection legislation. The CE Mark is obligatory for products it applies to:
the manufacturer affixes the marking in order to be allowed to sell his product in the
European market.

megascan M1
User Manual Rev. 1.0 Updated on 28th
August, 2009
(This user manual / product specification is subjected to be changed without prior notice) P.
4
Chapter 1 Introduction of megascan M1
1.1 Overview of megascan M1
The Megabyte Ltd., megascan M1 RFID reader does more than simply read and acts as a
data conduit, they need processing speed and ample memory. is an UHF RFID reader,
which includes powerful RFID reader with 17 RFID antenna ports, which operates in
860MHz to 930MHz UHF band and is compliance with ISO 18000-6C Tag Air Interfaces
with read and write function. megascan M1 reduces implementation cost and deployment
time; improves reliability in harsh environments and enhances overall RFID system
performance.
•The megascan M1 Intelligent RFID Reader supports protocols, UHF CLASS 1
GEN2 EPC C1G2/ISO 18000-6C, (865-868 MHz RFID frequency band) in Europe
as well as (902-928 MHz RFID frequency band) in United States.

megascan M1
User Manual Rev. 1.0 Updated on 28th
August, 2009
(This user manual / product specification is subjected to be changed without prior notice) P.
5
1.2 Ports Description
The megascan M1 has several types of input/output port:
Items Name Description
1 Ethernet Port, RJ-45 10BaseTx/100BaseTx port that connects the reader to your
Ethernet network, which is embedded with Power over
Ethernet (PoE) Technology.
2 UHF RFID Antenna Port(s) 17 SMA ports for external UHF antenna connection;
-16 ports with LED signal light,
- 1 dedicate RF output ports for M2 connection,

megascan M1
User Manual Rev. 1.0 Updated on 28th
August, 2009
(This user manual / product specification is subjected to be changed without prior notice) P.
6
1.3 Indicators LEDs in megascan M1
The megascan M1 has different LEDs to indicate the reader status.
Name Label Description
LAN Status, 10BaseTx 10M Turn ON when 10Mbps network detected
LAN Status, 10BaseTx 100M Turn ON when 100Mbps network detected
Ready, Read and write READY Turn ON when M1 is POWER ON,
Flashes when M1 is reading.
Antenna Ports 1-16 1,2 …16 Turn on when the antenna is ready to
perform schedule task

megascan M1
User Manual Rev. 1.0 Updated on 28th
August, 2009
(This user manual / product specification is subjected to be changed without prior notice) P.
7
1.4 Antenna for megascan M1
There is no antenna shipped with megascan M1. The following antenna model is used for
megascan M1:
MRD E42

megascan M1
User Manual Rev. 1.0 Updated on 28th
August, 2009
(This user manual / product specification is subjected to be changed without prior notice) P.
8
1.5 Product Features
•Excellent RFID monostatic RF performance with 17 external SMA antenna ports,
•1 Watt (30dBm) Tx output levels and -80dBm Rx read sensitivity,
•Consistently supports read ranges up to 30 feet,
•Dense Reader Mode (DRM) Capability,
•Power over Ethernet (PoE) connectivity,
•Low power consumption,
•Adjustable output Tx power levels over +5 to 30dBm range in 1dB steps,
•RJ-45, 10/100Mbps Ethernet interface, TCP/IP,
•Small Form, Fit size: 257mm(L) x 182mm(W) x 25mm(H),
•Standalone and Server mode middleware control support,
•High durability in harsh environments,
•Easy installation and maintenance,
•All-in-one compact design,
•Fanless Design for protection of dirt, dust, insects, liquids,
•Supporting tag interface of
EPC C1G2/ISO 18000-6C(UHF C1G2),

megascan M1
User Manual Rev. 1.0 Updated on 28th
August, 2009
(This user manual / product specification is subjected to be changed without prior notice) P.
9
1.6 Specification:
Features
Compliant with EPC global C1G2/ISO 18000-6C,
Dense eader Mode Capability,
Adjustable Output Power (up to +30dBm Max),
Exceptional Performance and eliability,
Low Power Consumption,
ead Distance up to 30 feet(9m),
Air-interface Protocols EPC Gen 2 / ISO 18000-6C,
Frequency Band
FCC 902-928 MHz,
ETSI 865-868 MHz,
NCC 922-928 MHz,
S C 920-925 MHz,
RF Output Power Adjustable from +5 to + 30dBm in 1 dB steps,
Supply Voltage Power over Ethernet (PoE), IEEE standard. 802.3af compliant,
Power Consumption Idle mode: 0.2W,
Scan mode: 8.95W@30dBm,
Communication Interface J-45, 10/100Mbps Ethernet Interface, TCP/IP,
Regulatory
FCC 47 CF Ch.1 Part 15,
ETSI EN 302-208,
NCC LP002,
oHS,
ags Supported Alien, Avery Dennison, Hitachi, Impinj, NXP, Omron, afsec, TI,
Physical Size 257mm (L) x 182 mm (W) x 25 mm (H),
External Antenna 17 ports SMA connector support external Monostatic Antenna up to 6dBi
VSW < 1.5:1 @ 50ohm,
Effective Range Over 30 feet (9 meters) with 6dBi External Antenna ,
Environment Storage Temperature: -40°C to 85°C,
Operating Temperature: 0°C to 40°C,

megascan M1
User Manual Rev. 1.0 Updated on 28th
August, 2009
(This user manual / product specification is subjected to be changed without prior notice) P.
10
Chapter 2 Installation of megascan M1
2.1 Power up megascan M1
This section explains how to set-up megascan M1 and connect the megascan M1 to your
network and antenna:
-Choose the PoE feature router/switch and compliance with IEEE std.
802.3af-2003, and connect with Cat.5 and higher infrastructure cable,
-Antenna port is standard SMA Jack(female), the RF cable/antenna connector
should be standard SMA Plug(male),
-megascan M1 operates at UHF frequency band, ranging from 865MHz to 928MHz
(ETSI 865-868 MHz, FCC 902-928 MHz, SRRC 920-925 MHz and NCC 922-928
MHz); the setting depends on countries’ regulations.
-Choose the right frequency band UHF antenna for your application.
2.2 Environmental Requirements
The next table includes environmental requirements for the megascan M1. Choose a
location that meets these requirements.
Description Minimum Maximum
Operating temperature 0ºC 55ºC
Storage temperature -40ºC 85ºC
Humidity (non-condensing) 10% 90%
Tabla de contenidos