Me GSV-4 Manual de usuario

4 channel measuring amplifier GSV-4
GSV-4BT
GSV-4USB
Operating instructions
Status: 14.10.2014
ME-Meßsysteme GmbH, Neuendo fst . 18a, 16761 Hennigsdo f, Ge many
Tel +49 (0)3302 78620 60, Fax +49 (0)3302 78620 69, [email protected], www.me-systeme.de 1

Contents
Inhaltsverzeichnis
DMS measu ing amplifie GSV-4USB...................................................................................3
Desc iption.........................................................................................................................3
Dimensions........................................................................................................................4
Technical data....................................................................................................................5
Connection assignment.....................................................................................................6
St ain Gage measu ing amplifie GSV-4BT.........................................................................17
Desc iption.......................................................................................................................17
Dimensions......................................................................................................................17
Technical data..................................................................................................................18
Wi ing diag am.................................................................................................................19
P og amming / configu ation................................................................................................23
Scaling of measu ed values.............................................................................................23
Measu ing ange 2.0 mV/V..............................................................................................23
Measu ing ange 10.0 mV/V............................................................................................23
Measu ing ange 0.0 to 5 V.............................................................................................24
Measu ing ange 0.0 to 10 V...........................................................................................24
Measu ing ange PT1000................................................................................................24
Measu ing ange K the mocouple cable..........................................................................24
Commands fo configu ation............................................................................................25
List of commands.............................................................................................................25
Desc iption of commands................................................................................................27
P otocol fo measu ed values..........................................................................................29
P otocol fo commands....................................................................................................29
P otocol fo esponding to commands.............................................................................30
Digital IOs........................................................................................................................31
Analogue input.................................................................................................................34
CAN bus...............................................................................................................................35
P otocol fo measu ed values..........................................................................................35
P otocol fo commands....................................................................................................35
P otocol fo esponding to commands.............................................................................35
Configu ing the CAN-ID...................................................................................................36
Data f equency and filte ..................................................................................................37
Analogue filte ..................................................................................................................37
Digital filte .......................................................................................................................37
ME-Meßsysteme GmbH, Neuendo fst . 18a, 16761 Hennigsdo f, Ge many
2 Tel +49 (0)3302 78620 60, Fax +49 (0)3302 78620 69, [email protected], www.me-systeme.de

DMS measuring amplifier GSV-4USB
GSV-4USB M12
F ont view senso connection
GSV-4USB SUB-D37
F ont view senso connection
Description
This 4-channel measu ing amplifie fo senso s with st ain gauges is equipped with a USB
inte face. The voltage is supplied via the USB po t at the back of the measu ing amplifie .
The measu ing amplifie can be delive ed with an SUB-D37 connection o with 4x M12
po ts. The measu ing amplifie has eight digital inputs and outputs.
ME-Meßsysteme GmbH, Neuendo fst . 18a, 16761 Hennigsdo f, Ge many
Tel +49 (0)3302 78620 60, Fax +49 (0)3302 78620 69, [email protected], www.me-systeme.de 3
•4-channels
•Powe supply via USB po t
•Inputs fo DMS / 0–5 V / PT1000
•Measu ement anges 2 mV/V / 10 mV/V
•DMS qua te / half / full b idges
•8 digital inputs / outputs
•Data ate 0 Hz–125 Hz

Dimensions
Figure 2: Dimensions GSV-4USB M12
ME-Meßsysteme GmbH, Neuendo fst . 18a, 16761 Hennigsdo f, Ge many
4 Tel +49 (0)3302 78620 60, Fax +49 (0)3302 78620 69, [email protected], www.me-systeme.de
Figure 1: Dimensions GSV-4USB SUB-D37

echnical data
1.Accu acy class 0.05 %
Inputs
Resolution 16 Bit
DMS inputs
Full b idge
Half b idge
Qua te b idge
350-5000
350-5000
120 / 350 / 1000
Ohm
Ohm
Ohm
Common mode ejection
at 60 Hz common-mode signal 95–110 dB
Measurement frequencies
Data f equency 0–125 Hz
Sampling f equency 1.92 MHz
Cut-off f equency
analogue
digital
1000
Notch filte
Hz
Hz
Outputs
B idge supply voltage
Cu ent load capacity
2.5
10
Volt
mA
Fixed voltage output
Cu ent load capacity
5
20
V
mA
Switching outputs/inputs
I/O 1-8
Cu ent load capacity:
TTL level
5 (active High)
5
V
mA
Inte face USB 1.1, USB 2.0 compatible
Supply voltage
Nominal ange
Isolation voltage
Cu ent consumption
4.5...5.5 via USB po t
1000
< 200
V DC
V ms
mA
emperature range
Nominal tempe atu e ange
Sto age tempe atu e ange
Ze o point d ift
Sensitivity d ift
-10…+65
-40…+85
< 0.05
< 0.01
°C
°C
%/10°C
%/10°C
Dimensions
L x W x H 106 x 119 (132) x 32 mm x mm x mm
Protection type / Weight
P otection type IP40
Weight GSV-4USB SUB-D37 239 g
Table 1: Technical data GSV-4USB
ME-Meßsysteme GmbH, Neuendo fst . 18a, 16761 Hennigsdo f, Ge many
Tel +49 (0)3302 78620 60, Fax +49 (0)3302 78620 69, [email protected], www.me-systeme.de 5

Connection assignment
Connection plan for 37-pin D-sub port
GSV-4USB assignment 37-pin D-sub port (PIN No.)
Channel 1 Channel 2 Channel 3 Channel 4
+USpositive senso supply 20 2 11 29
+UDpositive diffe ential input 22 4 13 31
QB1000 qua te b idge extension 1kOhm 23 5 14 32
HB half b idge extension 24 6 15 33
-UDnegative diffe ential input 25 7 16 34
-USnegative senso supply 27 9 18 36
UEanalogue input 28 10 19 37
sc een 1 1 1 1
Table 2: Analogue inputs
Connection assignment for GSV-4USB M12
5-pin port M12x1, type 763
Top view:
5-pin Description Colour code for
cables
2 -US negative b idge supply white
1 +US positive b idge supply b own
3 +UD positive diffe ential input blue
4 -UD negative diffe ential input black
5 AUXin input without cable g ey
ME-Meßsysteme GmbH, Neuendo fst . 18a, 16761 Hennigsdo f, Ge many
6 Tel +49 (0)3302 78620 60, Fax +49 (0)3302 78620 69, [email protected], www.me-systeme.de
1
19
37 20
12
4 3
5

Connection of full bridge with SUB-D37 version
The following g aphics show the connection of a full b idge to channel 1 th ough to
channel 4.
ME-Meßsysteme GmbH, Neuendo fst . 18a, 16761 Hennigsdo f, Ge many
Tel +49 (0)3302 78620 60, Fax +49 (0)3302 78620 69, [email protected], www.me-systeme.de 7

Connection of half bridge with SUB-D37 version
The following g aphics show the connection of a half b idge to channel 1 th ough to
channel 4.
The b idge extension should be adapted depending on the application.
ME-Meßsysteme GmbH, Neuendo fst . 18a, 16761 Hennigsdo f, Ge many
8 Tel +49 (0)3302 78620 60, Fax +49 (0)3302 78620 69, [email protected], www.me-systeme.de

Connection of quarter bridge with SUB-D37 version
The following g aphics show the connection of a qua te b idge to channel 1 th ough to
channel 4.
The b idge extension should be adapted depending on the application.
ME-Meßsysteme GmbH, Neuendo fst . 18a, 16761 Hennigsdo f, Ge many
Tel +49 (0)3302 78620 60, Fax +49 (0)3302 78620 69, [email protected], www.me-systeme.de 9

Connection of full bridge with M12 version
The following g aphic shows the connection of a full b idge fo the M12 ve sion.
Connection of half bridge with M12 version
The following g aphic shows the connection of a half b idge fo the M12 ve sion.
The b idge extension should be adapted depending on the application.
Please set the solder bridges:
•HB1 when using channel 1
with a half b idge.
•HB2 when using channel 2
with a half b idge.
•HB3 when using channel 3
with a half b idge.
•HB4 when using channel 4
with a half b idge.
Solde b idges: Figu e 3: Solde b idges fo
configu ing b idge extensions
see page 11
ME-Meßsysteme GmbH, Neuendo fst . 18a, 16761 Hennigsdo f, Ge many
10 Tel +49 (0)3302 78620 60, Fax +49 (0)3302 78620 69, [email protected], www.me-systeme.de
Otros manuales para GSV-4
1
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Amplificador de Me