matson RA3800 Manual de usuario

RA3800 JUMP START

Revision Status
TopicRevision ChangeRev
Document Released20150211
RA3800 | 20150211
2

Contents
Revision Status...........................................................................................................................2
Safety...........................................................................................................................................4
General Information..................................................................................................................5
RA3800 Operation.....................................................................................................................7
MAC02 Charger.........................................................................................................................8
Maintenance and Fault Finding..............................................................................................10
Warranty...................................................................................................................................12
3RA3800 | 20150211

Safety
This manual contains important safety and operating instructions for the RA3800 jump start. Read
this manual carefully before using.
Consider ALL safety, warning and caution instructions carefully.
Warning
1. The equipment is intended for use by adults and should not be operated by children
2. The jump starter described in this manual is suitable for portable and emergency power applications.
DO NOT exceed ratings nominated in the specications
3. DO NOT attempt to charge or boost a frozen lead-acid battery
4. The jump start is equipped with polarity protection in the OFF position - prevent clamps from touching
each other or contacting metal to stop accidental arcing
5. Only use attachments supplied with the equipment - failure to do so may result in personal injury or
equipment damage or void warranty
6. When disconnecting power, pull by the plug - DO NOT pull on the power lead
7. Replace a damaged charger power lead immediately. Do not attempt to recharge the jump start if the
equipment is damaged
8. Prevent submersion in water
9. Dispose of any faulty batteries in an environmentally responsible manner
10. DO NOT leave the jump start in a total discharge state for any period of time - permanent battery
damage can result. When not in use, leave the jump start connected to the supplied battery charger, or
recharge monthly and after every jump start performed.
Avoid contact with battery acid - it is highly corrosive, causing burn injuries and equipment
damage.
Wear safety glasses to prevent eye injuries.
If acid contacts eyes - ush immediately with cold water for 10 minutes, and seek medical
attention
Wear protective clothing to prevent acid contacting the skin.
If battery acid contacts skin - wash immediately with soap and fresh water.
Remove all jewellery and personal metal items when working with a lead-acid batteries.
• A lead-acid battery can generate explosive gases during normal battery operation. To reduce
risk of explosion, follow these instructions, those of the battery manufacturer and of any
equipment being used in vicinity of battery
• Use the jump start in a well ventilated area. DO NOT operate in the vicinity of ammables
such as petrol etc
• Short circuiting the contacts can generate a spark, creating a potentially explosive situation -
take care with tools and components
• Never smoke while working with a lead-acid battery. Do not allow sparks or ame near the
battery
RA3800 | 20150211
4

General Information
Operational and Safety Design Features
The RA3800 jump start provides enough power to start most vehicles and:
1. Is designed for 12/24V
2. Contains 2 x 500CCA batteries
3. Supplies 1000/500 CCA
4. Connects to the battery with 50mm² boost cable with copper jaws
5. For optimum performance, do not store below 10ºC when using as a jump starter
Alternative Power Supply
Most vehicles have electronic components - alarm systems, radios, etc whose memory can be lost when
the battery is disconnected. The jump start is a useful tool when replacing a battery - connect the jump
start clamps to the vehicle battery cables / terminals BEFORE disconnecting them from the battery posts.
Vehicle remains powered from the jump start.
• Use only as emergency power.
• Batteries are not intended for cyclic applications - battery life is reduced
• Discharging below 12.2 / 24.4 volts can damage the internal batteries
Multi Purpose Power Source
1. The jump start can power most equipment incorporating a 12 volt DC male adapter. The jump start
DC outlet has overload protection. DC power is generated only through the DC outlet
2. Used with an inverter, the jump start can operate appliances normally powered by 240 VAC.
3. A maximum 150 Watt inverter is recommended because the RA3800 DC 12 VOLT socket is powered
from the 2 batteries tted.
Antizap®Protection
Antizap®Surge Protection tted to the RA3800 protects against surges and spikes. When the clamps are
correctly connected, the Antizap Surge Protection LED illuminates - indicating the entire circuit is
protected.
STOP IMMEDIATELY if the REVERSE CONNECTION and WARNING LED sounds / lights - the
clamps are connected in reverse. Remove the clamps and reconnect correctly.
• Risk of Short Circuit.
•The REVERSE polarity LED and buzzer only provides an indication of a short circuit
if the RA3800 is switched OFF.
Ignoring these warnings and switching the RA3800 ON or,
Switching the RA3800 ON and then connecting incorrectly could result in:
• Personal injury to people in the vicinity,
5RA3800 | 20150211

• Equipment or vehicle damage,
• Sparks, ame and heat.
• The warranty being void
Specifications
RA3800
1.52M - 50mm² DC cableCable Length
3800 @ 12VPeak Amps
1900 @ 24V
1000 CCA @ 12 VoltCold Cranking Amps -
CCA 500 CCA @ 24 Volt
12VDC and 24VDCVoltage Options
Antizap®Surge / Spike protection - when unit is in ON positionVoltage and Current
Protection
Green ashing LEDAntizap®Operational
Indication
Red LED and Warning Buzzer in the OFF position onlyReverse Connection
Warning
20.4kgsWeight
12V with overload protectionDC Power Outlet
AnalogueVoltmeter
From 240VAC using MAC02 charger providedRecharge Capability
2 x 500CCABatteries
36 x 16 x 36.6 cmDimensions
1 year - excluding batteryWarranty
RA3800 | 20150211
6

RA3800 Operation
Initial Charge
Before using the jump start for the rst time, charge the unit for 24 hours, or until the MAC02 Battery
Charger supplied with the equipment indicates fully charged.
Testing RA3800 Charge Status
Test 12VDC Status - Switch to 12V position then press and hold TEST switch. VOLT METER indicates
status
Test 24VDC Status - Switch to 24V position then press and hold TEST switch. VOLT METER indicates
status
Operation
1. Turn the ignition off before making connections
2. Ensure the RA3800 voltage selector is in the OFF position
3. Attach the red / positive +clamp to the battery positive terminal
4. Attach the black / negative -clamp to the battery negative terminal
5. The RA3800 voltmeter displays the voltage of the battery being started. If less than 3 volts on 12 volt
setting, or 6 volts on 24 volt setting - do not attempt to jump start the vehicle. The battery voltage is
too low - an attempted jump start would be dangerous. Replace the battery.
6. If displayed voltage is above 3 volts on 12 volt setting, or 6 volts on 24 - select either 12V or 24V
7. Keep cables clear of moving objects
8. Keep people clear of the battery area
9. Turn vehicle ignition on. If vehicle does not start after 6 seconds, allow the RA3800 to cool for 3
minutes before attempting to restart the vehicle. This avoids damage to the unit.
10. Once started, disconnect the black / negative -clamp from the battery negative terminal. Then remove
the red / positive +clamp.
• Risk of Short Circuit.
• The REVERSE polarity led and buzzer only provides an indication of a short circuit
if the RA3800 is switched OFF.
Leave the RA3800 on charge when not in use - the MAC02 is a Charger / Maintainer
and will maintain the batteries in peak condition longer. Turn the switch to the 12V
position for charging. In the OFF position - only 1 of the 2 batteries are charged
7RA3800 | 20150211

MAC02 Charger
General
The MAC02 Battery Charger is a fully automatic microprocessor controlled battery charger / maintainer.
MAC02 Basic Operation
1. Ensure the MAC02 and the RA3800 are switched OFF before plugging MAC02 into the RA3800
2. Turn the RA3800 12V / OFF / 24V switch to the 12V position for charging.
3. Plug MAC02 charger into 240VAC and switch power on
4. Plug MAC02 male plug into the 12VDC socket on the front of the RA3800
5. MAC02 starts charging when it senses the battery voltage. CHARGING LED is solid red.
6. ABNORMAL LED ashes amber if the MAC02 detects a problem with the battery.
7. When the battery is fully charged - CHARGE LED is solid green.
RA3800 | 20150211
8

Leave the RA3800 on charge when not in use - the MAC02 is a Charger / Maintainer
and will maintain the batteries in peak condition longer
9RA3800 | 20150211

Maintenance and Fault Finding
Maintenance
1. Keep the jump start fully charged
2. Recharge upon purchase and immediately after each use
3. Recharge if not used for two months
4. It is recommended to continuously the jump pack - the unit will not be damaged
Troubleshooting
Possible SolutionProblem
Charger works, but there is no volt charge on the
display when the Switching Power Charger is
connected to the jump pack
1. Possible defective battery or faulty switch. Try
using a device - light, TV, etc with a DC plug
on it to see if it works
2. If it works, the jump start battery is operational
and the switch may be faulty
Charger comes to full charge, but display indicates
low voltage
1. Jump start has a defective battery - could be the
result of intense use without allowing a cool
down period
Jump start is fully charged, but has no power 1. Check where the wire meets the jaw on the jump
start clamp. Ensure they are well crimped, or
2. Ensure power switch is in the ON position.
Frequently Asked Questions - FAQ
Q: How many jump starts can I expect from a fully charged unit before needing to be recharged?
A: Depends on the engine type and size, condition of battery and temperature - the jump start may be
used up to 20 times before recharging in normal use environments.
Q: What is the ideal jump start storage temperature?
A: The jump start operates most effectively when stored at room temperature. The unit also operates at
below 0º conditions, but with less cranking power. Excessive heat accelerates self discharge.
Q: When recharging the unit, when do I know the jump start is fully charged?
A: Check MAC02 Operating Instructions
Q: How long should I charge the jump start?
A: Charge the jump start for a minimum of 24 hours when rst purchased. The unit can be left on the
wall charger continuously without damaging the unit.
Q: Can the self contained battery be recycled?
A: Yes - refer to REMOVAL AND DISPOSAL instructions
Q:How often should I charge the RA3800?
RA3800 | 20150211
10
Tabla de contenidos