Mark-10 DC Series Manual de usuario

Digital Controllers Series DC
MODELDC4010 / ESMH-DC
MODELDC4020 / ESM-DC
MODELDC4030 /TSFM500-DC
MODELDC4040 /TSTM-DC
User’s Guide

Series DC Digital Controllers
Thank you!
Thank you for purchasing a Mark-10 Series DC digital test stand controller,
designed for use with Mark-10 motorized test stands. Mark-10 test stands and
controllers are ruggedly built for many years of service in laboratory and
industrial environments.
This User’s Guide provides setup, safety, and operation instructions for the
digital controller. Dimensions and specifications are also provided. Instructions
for the test stand may be found in a separate user’s guide.
For additional information or answers to your questions, please do not hesitate
to contact us. Our technical support and engineering teams are eager to assist
you.
Before use, each person who is to use a Series DC digital controller and
Mark-10 test stands should be fully trained in appropriate operation and
safety procedures.
TABLE OF CONTENTS
LIST OF INCLUDED ITEMS...................................................... 3
OVERVIEW.................................................................................3
MECHANICAL SETUP AND SAFETY.......................................4
CONTROLS LAYOUT................................................................7
TEST PARAMETER SETUP......................................................8
OPERATING MODES...............................................................20
COMMUNICATING WITH MESURGAUGE.............................27
SPECIFICATIONS....................................................................29
DIMENSIONS ...........................................................................29
WARRANTY .............................................................................29
OTHER MARK-10 PRODUCTS ...............................................31

User’s Guide
3
1 LIST OF INCLUDED ITEMS
2 OVERVIEW
There are several models within this series of digital controllers to
accommodate different test stands, as follows:
Series DC controllers have two functional modes:
1. OPERATING MODE
This is the operating mode in which testing sequences can be started and
stopped.
2. TEST PARAMETER SETUP
In this mode, test parameters are configured, such as rate of speed, number of
cycles, password editing, and other parameters.
Qty. Item
1 Series DC digital controller
1 Power cord
1 Cable, controller to test frame
1 09-1143 multi-function cable (optional)
1 09-1056 serial cable (optional)
Model For use with
DC4010 ESMH
DC4020 ESM
DC4030 TSFM500 / TSFM500H
DC4040 TSTM / TSTMH

Series DC Digital Controllers
4
3 MECHANICAL SETUP & SAFETY
3.1 Mounting
The controller should be placed on a clean, flat and level work area free from
vibration. If desired, the controller can be secured to the work area with 1/4-20
screws fastened into the underside of the housing. The controller can also be
mounted using the ESM301-003 mounting kit. Screws of various lengths are
supplied with this kit to accommodate a range of bench thicknesses. Refer to
the following illustration for proper assembly:
In general, the controller can be mounted at any angle, although extra care
should be taken during installation and operation.
3.2 Setting Up The Controller
The power plug and controller cable must be connected to the rear of the
controller, as shown in the illustration below:
IMPORTANT: Do not fasten any screws more than 0.25
in [6 mm] into the base of the test stand, or damage to
internal components can occur.

User’s Guide
5
1. Fuse
2. STAND / Controller Cable Connector
Plug one end of the cable into this connector, and the other end into the
connector adjacent to the motor on the test stand. If this cable is not
connected, the error message ENCODER ERROR will be shown on the
display and the test stand cannot be operated.
3. PC / PC Control Connector
Plug one end of the 09-1056 serial cable into this connector, and the other
end into a serial connector on a computer.
4. Power Plug Receptacle
Plug the power cord in here.
5. ENCODER / Travel Indication Connector
Applicable for TSTM / TSTMH test stands only
Plug one end of the RJ11 cable into this connector, and the other end into
the connector on the underside of the mechanism housing on the test stand.
6. GAUGE / Gauge Cable Connector
Plug one end of the 09-1143 cable into this connector, and the other end
into a Series 5, Series BG or BGI gauge.

Series DC Digital Controllers
6
3.3 Connecting Power
Plug one end of the power cord into its receptacle at the rear of the controller
and the other end into a wall outlet with local earth ground (3-prong connector).
Before turning on power, the following safety checks and procedures should be
performed:
1. Never operate the controller if there is any visible damage to the power
cord or the test stand. The controller is powered by 110V/220V. Any
contact with this high voltage can cause serious injury or even death.
2. Ensure that the controller is kept away from water or any other
electrically conductive liquids at all times.
3. Make sure the electrical outlet powering the controller has local earth
ground (3-prong connector).
4. The controller should be serviced by a trained technician only. Power
must be disconnected before the controller is opened.
After the above safety checks and procedures have been performed, the
controller may be powered on and is ready for operation.

User’s Guide
7
4 CONTROLS LAYOUT
* Although the direction of movement differs between test stands, this user’s
guide will refer to the buttons as UP and DOWN.
EMERGENCY
STOP
SOFT KEYS
UP
STOP /
ZERO TRAVEL DISPLAY
DOWN
DISPLAY
SOFT KEYS Functions are determined by the
corresponding text on the display.
UP /
RIGHT / CW* Initiates movement in the up, right, or
clockwise direction, depending on the test
stand.
DOWN /
LEFT / CCW* Initiates movement in the down, left, or
counterclockwise direction, depending on the
test stand.
STOP Stops movement.
EMERGENCY
STOP Stops movement and disables the test stand
until reset.

Series DC Digital Controllers
8
5 TEST PARAMETER SETUP
This section provides configuration instructions for each test parameter. The
initial Test Parameter Setup screen appears as follows:
When the parameters have been configured as desired and are ready to be
saved, press ESC to exit Test Parameter Setup. The screen will show SAVE
CHANGES? Pressing YES will save the changes and the display will revert to
current status. Pressing NO will not save the changes and return to the Test
Parameter Setup menu.
Note: Changes can be made to an unlimited number of settings before
saving.
UNITS: in/min
ESC > NTRE
_
<_
ESC Exits Test Parameter Setup, reverts to Operating
Mode
< – Scrolls to the previous parameter
– > Scrolls to the next parameter
ENTR Selects the parameter, allowing it to be modified

User’s Guide
9
The following is a flow chart for the menu structure:
MENU
SAVE CHANGES
UP SPEED
DOWN SPEED
AUTO RETURN
CYCLES
UPPER DWELL
LOWER DWELL
UNITS
KEYS
DEFAULT SETTINGS
NEW PASSWORD
OPERATING MODE
ENTR ESC
ENTR
+ (inc) - (dec)
ENTR ESC
ENTR
ENTR ESC
ENTR
+ (on) - (off)
ENTR ESC
ENTR
ENTR ESC
ENTR
ENTR ESC
ENTR
ENTR ESC
ENTR
+ (in) - (mm)
ENTR ESC
ENTR
ENTR ESC
ENTR
+ (yes) - (no)
ENTR ESC
ENTR
+ (inc) - (dec)
+ (inc) - (dec)
+ (inc) - (dec)
+ (inc) - (dec)
ESC
ESC
ESC
ESC
ESC
ESC
UPPER LM ENTR ESC
ENTR
+ (inc) - (dec)
ESC
LOWER LM ENTR ESC
ENTR
+ (inc) - (dec)
ESC
+ (inc) - (dec)
ESC ENTR ESC
ENTR
ENTR ESC
ENTR
+ (inc) - (dec)
ESC
ENTR ESC
ENTR
+ (inc) - (dec)
ESC
OVRLOAD V
C OVERLOAD
T OVERLOAD
ENTR ESC
ENTR
ESC
ENTR ESC
ENTR
+ (inc) - (dec)
ESC
ENTR ESC
ENTR
+ (inc) - (dec)
ESC
+ (inc) - (dec)
+ (inc) - (dec)
ESC
ESC
ESC
ESC
CONTROL
BAUD RATE
STOP & PAR
+ (PC) - (CONSOLE)

Series DC Digital Controllers
10
5.1 Speed
Independent speeds can be set for both directions of movement. The
parameters are labeled as follows:
Default speed settings and available speeds are as follows:
Test stand Parameter labels
ESMH L SPEED, R SPEED
ESM UP SPEED, DN SPEED
TSFM500 /
TSFM500H UP SPEED, DN SPEED
TSTM /
TSTMH CW SPEED, CCW SPEED
Test stand Default
speed
ESMH 10 in/min
ESM 10 in/min
TSFM500 /
TSFM500H 5 in/min
TSTM / TSTMH 6 RPM
Available settings
in/min [mm/min]
0.2 - 50 [5 - 1270]
0.02 - 36 [0.5 - 900]
0.01 - 6 [0.2 - 150]
0.01 - 15 RPM [0.05 - 90°/s]
UP SPEED: 10.73
ESC ENTR
+
_
+
Increments the speed setting. Holding down +will
increment at an increasingly faster rate.
–
Decrements the speed setting. Holding down –will
decrement at an increasingly faster rate.
ENTR Returns to the Test Parameter Setup menu
ESC Exits the parameter without saving changes