4
Program and Program settings
Programming ability and door control at electrical box are provided by Open/Close/Stop buttons and Select
Switch located on the ECB.
• Programs
• Program setting
Door should be in fully closed position while setting of these following programs.
PROGRAMS FUNCTIONS AND DESCRIPTIONS
RUN TIMER The Run Timer stops automatically the operator after an adjustable time delay either
travelling upwards or downwards. The Run Timer is designed to protect the door and
the operator by preventing the motor over running much longer than the normal time.
MID-STOP Mid-Stop function will, when active, move the door from the down position to a
predetermined Mid-stop position when the open button or Open/Close device is
activated. Once at Mid-Stop, subsequent Open/close commands will close the door. To
move the door to full open position, the open button must be pressed again.
TIMER TO CLOSE Timer to Close is a function that, when active, will close the door after an adjustable
time delay once the door has reached its fully open and mid-stop position. The timer to
close function works only in T and TS modes.
TIMER TO CLOSE (from
fully open position only) Option used in conjunction with MID STOP function. When activated, Timer to Close is
active from the fully open position only and not from the mid-stop position.
ADVANCE CLOSED
TIME
“Advance close limit switch” is not needed with this feature. Advance close time will
disable the reversing device once the close limit switch is activated and will stop the
door after 200 milliseconds before it reaches the fully closed position.
Note: Door distance traveled within these 200 milliseconds may vary depending on the
door speed.
PROGRAM SETTING
PROGRAMS ACTIVATE DEACTIVATE SELECT
SWITCH
RUN TIMER
• Check if close limit switch is activated.
• Set select switch on D.
• Press “Open” button to add 10 sec to the
total time needed to open the door.
• Set the select switch on run mode (0, 1, 2, 3,
4 or 5).
• Set select switch on D.
• Press “Stop” button.
• Set the select switch on run mode (0, 1, 2, 3,
4 or 5).
MID-STOP
• Check if the close limit is activated.
• Set select switch on “C”.
• Press “Open” button then press “Stop”
button on desired Mid-Stop position.
• Set the select switch back on run mode (0,
1, 4 or 5).
• Set select switch on “C”.
• Press “Stop”, “Close” and “Open” buttons
consecutively.
• Set the select switch back on run mode (0,
1, 4 or 5).
TIMER TO
CLOSE
• Set select switch on “B”.
• Press “Open” button to add 15 sec or
“Close” button to add 1 sec each time (max.
4 minutes & 15 seconds).
• Set the select switch on T or TS mode.
• Set select switch on “B”.
• Press “Stop” button the timer to close is
reset to 0 sec but still activated.
• To defeat the timer to close completely set
the switch on desired position (0, 1, 2 or 3).
TIMER TO
CLOSE
(from fully open
position only)
• Set select switch on ”6”.
• First press the “Close” button and then the
“Stop”.
• Set the select switch on T or TS mode.
• Set select switch on “6”.
• Press “Close” button.
• Set the select switch on T or TS mode.
*Now the Timer to Close works from fully open
and Mid-Stop positions.
Controlling Timer to Close from floor level (using wall buttons)
While door is in closed position, by pressing “Stop” 3 times and
“Close” 3 times consecutively on the push button station, the timer
to close is deactivated (timer to close is suspended).
Timer to close is re-activated (timer to close is back to
normal function) simply when door is closed either from fully
open or from mid-stop positions.
8
9
D
B
A
C
E
F
0
7
2
6
5
3
4
1
D
C
B
A
9
8
F
E
0
3
6
5
7
4
2
1
D
A
B
C
9
8
F
E
0
4
6
5
7
2
1
3
0
F
D
B
C
A
9
8
E
1
6
7
5
2
4
3