Magenta Research USB Link II Manual de usuario

USB Link II
User Guide
Magenta Research
128 Litchfield Road, New Milford, CT 06776 USA
(860) 210-0546 FAX (860) 210-1758
www.magenta-research.com

© 1998-2010 by Magenta Research All rights reserved.
Magenta Research
128 Litchfield Road
New Milford, CT 06776 USA
This document and the Magenta Research products to which it relates, and the copyright
in each, is the property of Magenta Research. Neither the document nor the products may
be reproduced by any means, in whole or in part, without the prior written permission of
Magenta Research. Magenta Research makes no warranty or representation, either
express or implied, with respect to this software or documentation, including their quality,
performance, merchantability, or fitness for a particular purpose. As a result, this
software or documentation are licensed "as is" and you, the licensee, are assuming the
entire risk as to their quality and performance.
In no event will Magenta Research be liable for direct, indirect, special, incidental, or
consequential damages arising out of the use of or inability to use the software or
documentation.
Magenta Research and the Magenta Research logo are trademarks of Magenta Research.
All other brands, product names, and trademarks are the property of their respective
owners.
MAGENTA USB LINK II

FCC Radio Frequency Interference Statement Warning
The USB Link II has been tested and found compliant with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when installed and operated in a commercial environment. The USB
Link II generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with this user guide, may cause harmful interference to radio communications.
Operation of the USB Link II in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
CE Statement
We, Magenta Research, declare under our sole responsibility that the USB Link II, to which this
declaration relates, is in conformity with European Standard EN 55022/A1 Class A, and
EN 50082-1 (IEC 801-2, IEC 801-3, IEC 801-4)
SAFETY WARNING
Installation • This equipment is to be installed in a restricted access location.
Connection • Not for direct connection to Telecommunication Network Circuitry (TNV)
Power sources • This equipment should be operated only from the power source indicated on
the product. This equipment is intended to be used with a main power system with a grounded
(neutral) conductor. The third (grounding) pin is a safety feature, do not attempt to bypass or
disable it. This equipment can be powered from redundant power sources. Disconnect all power
sources before servicing.
Power disconnection • To remove power from the equipment safely, remove all power cords
from the rear of the equipment, or from the power source receptacle (wall plug).
Power cord protection • Power cords should be routed so that they are not likely to be stepped
on or pinched by items placed upon or against them.
Servicing • Refer all servicing to qualified service personnel. There are no user-serviceable parts
inside. To prevent the risk of shock, do not attempt to service this equipment yourself because
opening or removing covers may expose you to dangerous voltage or other hazards.
Slots and openings • If the equipment has slots or holes in the enclosure, these are provided to
prevent overheating of sensitive components inside. These openings must never be blocked by
other objects.
FCC/IC RFI STATEMENTS, SAFETY WARNING.
1

Contents
Specifications.................................................................................................3
Introduction....................................................................................................4
USB Link Product Contents...........................................................................4
The Transmitter Unit………………………………………………………………5
The Receiver Unit…………………………………………………………………6
Cables, Power, & Compatibility………………………………………………….7
Before You Begin...........................................................................................9
Installing the TRANSMITTER Unit.................................................................9
Installing the RECEIVER Unit........................................................................9
Connecting the TRANSMITTER Unit to the RECEIVER Unit......................10
Checking the Installation..............................................................................11
Connecting a USB Device...........................................................................11
Troubleshooting...........................................................................................12
2
MAGENTA USB LINK II

3
Range (over Category 5
UTP cable)
150 meters (492 ft)
USB device support High speed devices (480 Mb/s)
Full speed devices (12 Mb/s)
Low speed devices (1.5 Mb/s)
USB hub support Any single chain can include four USB hubs and one
Link, in any order.
Power available to USB
device at TRANSMITTER
1 x 500 mA
Power available to USB
device at RECEIVER
4 x 550 mA
USB cable 2 meters (6.6 ft)
TRANSMITTER connector
(upstream)
1 x USB Type B
TRANSMITTER connector
(downstream)
1 x RJ-45
RECEIVER connector
(upstream)
1 x RJ-45
RECEIVER connector
(downstream)
4 x USB Type A (Hub)
TRANSMITTER dimen-
sions 110 mm x 88 mm x 30 mm
4.3” x 3.5” x 1.2”
TRANSMITTER weight 280 g (0.6 lbs.)
RECEIVER dimensions 140 mm x 88 mm x 30 mm
5.5” x 3.5” x 1.2”
RECEIVER weight 330 g (0.73 lbs.)
Humidity Up to 95%
Temperature range Operation: 0°C to 55°C, Storage: -20°C to 85°C
Specifications
Specifications

Introduction
Introduction
This manual is intended to assist with the installation of the USB Link II. The
instructions in this guide assume a general knowledge of computer installation
procedures, familiarity with cabling requirements, and some understanding of
USB devices.
NOTE:Notes give additional information that could make
installation easier.
USB Link II Product Contents
When you open your USB Link II for the first time you should find the following
items:
USB Link II User Guide
Local Transmitter
Remote Receiver
AC power adapter
USB cable(6 ft)
To complete the installation, you will also require the following items that are
not included with the product:
USB compatible computer
USB device
Category 5/6 Unshielded Twisted Pair (UTP) cable with two RJ45
connectors pinned to the T568B specification.
NOTE: The maximum length of the Category 5/6 UTP cable,
including patch cords, must not exceed 492 ft (150m).
4
MAGENTA USB LINK II

The USB Link II is composed of two individual units, the Local transmitter and
the Remote Receiver.
The Transmitter Unit
The transmitter unit connects to the host computer using a conventional USB
cable.
Front View Rear View
1Host Port (USB Type B)
2 Power LED (ON)
3 Link LED (LINK)
4Link Port (RJ45)
5
2 3
1
4
Transmitter

Receiver
The Receiver Unit
The receiver unit connects to the USB device using a conventional USB
cable. It also must be connected to a power outlet through an AC power
adapter. The receiver unit allows you to connect up to four USB devices.
Front View Rear View
1Power Connector
2Power LED (ON)
3Link LED (LINK)
4Link Port (RJ45)
54-Port USB Hub (USB Type A)
6
1 2 3 4 5
MAGENTA USB LINK II

Network Cabling
The transmitter and receiver units are interconnected by up to 150 meters of
Category 5/6 Unshielded Twisted Pair (UTP) cabling. The UTP cabling must
have a straight-through conductor configuration, with no crossovers, and must
be terminated with T568B specified RJ45 connectors at both ends.
NOTE:Category 5/6 UTP cabling is the standard data
communications cable installed in most commercial and
some residential buildings.
USB Cables
USB cables have two distinct connectors. The Type A connector is used to
connect the cable from a USB device to the Type A port on a computer or
hub. The Type B connector is used to attach the USB cable to a USB device.
7
USB Type A
port
USB Type A
connector
USB Type B
port
USB Type B
connector
Cables, Power, & Compatibility
Transmitter Receiver

Cables, Power, & Compatibility cont.
8
Power Handling
Some USB devices are powered directly from the USB and do not require
individual power supplies. These devices are called bus-powered devices.
The USB Link II can provide power to these devices so they can be operated
remotely.
Bus-powered devices are further divided into low-power and high-power cate-
gories. Low-power devices are allowed to draw up to 100 mA from the USB.
Typical examples include mice, joysticks, and keyboards without hubs. High-
power devices are allowed to draw up to 550 mA from the USB. Typical ex-
amples include cameras and keyboards with hubs. To determine if a device is
high-power or low-power, consult the user documentation for the device.
NOTE: Devices with their own power source are usually considered to be
low-power devices from a USB perspective.
Compatibility
The USB Link II complies with USB 2.0 and 1.1 specifications governing the
design of full speed USB devices. However Magenta Research does not
guarantee that all full speed USB devices are compatible with the USB Link II.
MAGENTA USB LINK II
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Extensor de Magenta Research


















