MacroAir Technologies AirLynk BACnet Manual de usuario

Operation Manual
MacroAir AirLynk
BACnet


Table of Contents MacroAir AirLynk
© 2019 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com
Rev Date: 071519
1
Introduction
Network Installation
Wiring Diagrams
Configuration and Operation
Appendices
Caution & Safety . . . . . . . . . . . . . . . . . . . . . 2
Fan Network Ordering . . . . . . . . . . . . . . . . . 3
AirLynk Enclosure,
AirLynk Components . . . . . . . . . . . . . . . . . . 4
Network Wiring Instructions . . . . . . . . . . . . 5
Repeater Install for 370 Fans. . . . . . . . . . . . 6
Network Wiring Requirements,
Daisy Chain . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Improper Wiring Configuration,
Proper Wiring Configuration . . . . . . . . . . . . 8
Excess Cable at Connection Point . . . . . . . . 9
Wiring: CAT5E Pin-Out,
Repeater (370 Fans) . . . . . . . . . . . 10
PLC . . . . . . . . . . . . . . . . . . . . . . . . . 11
A Quick Start Guide:
PLC Startup,
Fan Setup . . . . . . . . . . . . . . . . . . . . . . . . 12
BACnet MSTP Setup,
BACnet IP Setup. . . . . . . . . . . . . . . . . . . 13
Certifications . . . . . . . . . . . . . . . . . . . . . . . 14
Introduction,
BACnet Setup . . . . . . . . . . . . . . . . . . . . . . . 15
Interfacing PLC to Devices . . . . . . . . . . . . . 16
PLC’s Web Configurator . . . . . . . . . . . . . . 18
Appendix A: Control Points . . . . . . . . . . . . 19
Appendix B: Limited 2 Year Warranty . . . 24
Technical Support . . . . . . . . . . . . . . . . . . . 25

Introduction MacroAir AirLynk
© 2019 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com
Rev Date: 071519
2
Caution and Safety
⚠ ATTENTION: Safety. READ THE ENTIRE MANUAL BEFORE OPERATING THE FAN. Ensure that
all safety practices and instructions are followed during the installation, operation and servicing
of the fan. Failure to apply these safety practices could result in death or serious injury. If you do
not understand the instructions, please call our Technical Department for guidance.
⚠ ATTENTION: Qualified Technicians. All fan controls and incoming power should only be
installed by qualified technicians familiar with the requirements of the National Electrical Code
(NEC) and local codes. Refer to appropriate portions of this manual for other important
requirements. Failure to follow these guidelines will void the manufacturer’s warranty.
⚠ ATTENTION: Code Compliance. Installation is to be in accordance with the NEC, ANDSI/NFPA
70-1999 and local codes.
Hazard of Electrical Shock, Explosion or Arc Flash:
⚠ ATTENTION: Read. Read and understand this manual before installing or operating a fan unit.
Installation, adjustment, repair, and maintenance must be performed by qualified personnel.
⚠ ATTENTION: Code Compliance. The user is responsible for compliance with all international
and National Electrical Code requirements with respect to grounding of all equipment.
⚠ WARNING: Do Not Touch. Many of the parts of this unit operate at line voltage. DO NOT
TOUCH.
⚠ WARNING: Covers. Install all covers before applying power or starting and stopping the unit.
Installation and Service
⚠ WARNING: Damage. Do not operate or install any fans or fan accessories that appear to be
damaged.
⚠ WARNING: Death and Injury. Failure to follow this instruction can result in death, serious
injury, or equipment damage.
⚠ WARNING: Disconnect Power. If the fan does not operate properly using the procedures in
this manual. BE CERTAIN TO REMOVE ALL POWER TO THE UNIT and contact our technical
department for further assistance.
⚠ CAUTION: Moving Parts. Keep all body parts clear of moving parts at all times.
⚠ ATTENTION: Qualified Technicians. All electrical troubleshooting and repair must be done by
a qualified technician and meet all applicable codes.
REFER TO FAN INSTALLATION MANUAL(S) FOR FURTHER MAINTENANCE INFORMATION.

Introduction MacroAir AirLynk
© 2019 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com
Rev Date: 071519
3
Fan Network Ordering
It is important to purchase fans that are setup for a network. MacroAir customizes fans to
operate in a network by:
•Addressing the fans and
For 370 Fans:
•Supplying an additional length of CAT5
Note: For 370 Fans, Repeaters/Isolators must be added every 5 fans for stability. (Page 5)
*If you did not order your fans for a network by default they will all have a default Node Address,
and you will be missing necessary materials. Contact technical support to modify your fans when
installing for networking.

Introduction MacroAir AirLynk
© 2019 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com
Rev Date: 071519
4
AirLynk Enclosure
Dimensions
Components

5 Network Installation MacroAir AirLynk
© 2019 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com
Rev Date: 071519
Network Wiring Instructions
Refer to the appropriate fan installation manual for specific networking instructions.
Fans AVD3, 550, Y Series
Fan 780
Fan 370

6 Network Installation MacroAir AirLynk
© 2019 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com
Rev Date: 071519
Repeater Install for 370 Fans
Repeater/Isolator
The Repeater/Isolator boosts the signal along the network preventing signal “loss” and
minimizes noise on the line.
Repeaters/Isolators should be evenly placed in the network. Make sure there is at least one
Repeater/Isolator every 5 fans.

7 Network Installation MacroAir AirLynk
© 2019 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com
Rev Date: 071519
Network Wiring Requirements
•Use Stranded Twisted Pair, CAT5e (or higher grade) shielded cable
•Minimum 24 AWG (0.5mm) cross section
•Route wires as far away as possible from high voltage AC cables, fluorescent lights, arc
welders, and other equipment that transmits EMI (electromagnetic interference).
For 370 Fans:
•Ground the shielding and drain wire at only one point of the cable run
•Add Repeaters/Isolators (1/5fans)
Daisy Chain
Networked MacroAir fans must be connected in one single line, referred to in this document as a
“daisy chain”. The characteristics of a proper daisy chain are: one beginning (AirLynk) and one
end (last fan).
If the fans are not connected in one line/chain there will be a de-graduation of the
communication signal and the network may not function as intended (fans in the network may
not operate).
¤
- Control Panel
VFD MC
- Motor Control Cable (supplied with Fan by MacroAir)

8 Network Installation MacroAir AirLynk
© 2019 MacroAir Technologies Toll Free: 866 668-3247 Fax: 909 890-2313 www.macroairfans.com
Rev Date: 071519
Improper Wiring Configuration
End of Line x3 End of Line x8
Proper Wiring Configuration
ONE End of Line
Tabla de contenidos
Manuales populares de Tarjeta de red de otras marcas

3Com
3Com EtherLink 3C509B Manual de usuario

TRENDnet
TRENDnet TEG-PCITX Manual de usuario

Cisco
Cisco MC16E Manual de usuario

Delta Electronics
Delta Electronics Braking Modules VFDB Series Manual de usuario

TwinMOS
TwinMOS Booming Manual de usuario

Dialogic
Dialogic Media Board DM/V1200BTEPEQ Manual de usuario

Buffalo
Buffalo AirStation WLI-PCM-L11GP Manual de usuario

National Instruments
National Instruments NI 9234 Manual de usuario

Hama
Hama 49276 Manual de usuario

Linksys
Linksys WCF54G - Wireless-G Compact Flash Card Manual de operación

Compaq
Compaq Wireless LAN 100 Manual de usuario

Bose
Bose PowerMatch Dante Manual de usuario