Machfu i-ALERT Series Manual de usuario

i-ALERT® Gateway
Installation Manual
August 8, 2019
Revision 2.0

i-ALERT® Gateway Installation Guide
1/13
Notes, cautions, and warnings
NOTE: A NOTE indicates important information that helps you make better use of your product.
CA TION: A CA TION indicates either potential damage to hardware or loss of data and tells you how to avoid
the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.

i-ALERT® Gateway Installation Guide
2/13
Table of Contents
1 Overview ..............................................................................................................................................
2 System View ......................................................................................................................................... 5
2.1 Gateway Interface ......................................................................................................................... 5
2.2 Powering the Gateway .................................................................................................................. 6
2.2.1 AC Powered Gateway............................................................................................................ 6
2.2.2 9-60 VDC Powered Gateway ................................................................................................. 6
2.2.3 Conduit Fittings ..................................................................................................................... 7
2.3 Mounting Options ......................................................................................................................... 8
2.3.1 Wall Mounting ...................................................................................................................... 8
2.3.2 Pole Mounting ....................................................................................................................... 9
3 i-ALERT Gateway Quick Start Guide ................................................................................................... 10
3.1 Troubleshooting .......................................................................................................................... 11
Safety and regulatory information ..................................................................................................... 12
5 Regulatory Notices ............................................................................................................................. 12

i-ALERT® Gateway Installation Guide
3/13
REVISION HISTORY
Revision
Description
Date
0
.
1
Draft
release
/ /201
9
1.0
Draft revision
5/10/2019
2.0
Draft revision
6
/30
/2019
3.0
Final Revision
8/8/2019

i-ALERT® Gateway Installation Guide
/13
1 Overview
The i-ALERT
®
Gateway is an Industrial Internet-of-Things (IIoT) device. It is deployed on the ITT
Pro Services
®
cloud, enabling you to securely collect, analyze, and act on data from i-ALERT2
®
sensors. The gateway is designed to be plug and play and requires no setup other than physically
mounting the unit and applying power. The gateway can be ordered for use with 110/220VAC or 9-
60VDC, in both a North American and International versions. Part Numbers are as follows:
Model Part Number Description
i-ALERT Gateway Domestic,
AC Powered – SA K13653A- S 110-240 VAC, Domestic Cellular
Modem Assembly - SA
i-ALERT Gateway Domestic,
AC Powered - CD K13653A-CD 110-240 VAC, Domestic Cellular
Modem Assembly-Canada
i-ALERT Gateway Domestic,
DC Powered - SA K13654A- S 9-60 VDC, Domestic Cellular
Modem Assembly- SA
i-ALERT Gateway Domestic,
DC Powered - CD K13654A-CD 9-60 VDC, Domestic Cellular
Modem Assembly-Canada
i-ALERT Gateway Pole
Mount Bracket Kit K15535A
The pole mount kit can be used
with poles of diameter of 2 inches
to 12 inches.

i-ALERT® Gateway Installation Guide
5/13
2 System iew
2.1 Gateway Interface
The gateway interface points are shown in Figure 1:
1. Plug 1 is an expansion plug allowing an additional gland or conduit fitting to be added
2. Plug 2 is the gland for the power input cable
3. Plug 3 is a water tight air exchange vent
. Plug is the Cellular SIM card access plug
Figure 1: i-ALERT2® Gateway Interface Ports
. SIM Card
3. IP67/IP68 Rated
Air Vent
3. IP67/IP68 Rated
Hole Plug
3. IP67/IP68 Rated
Gland

i-ALERT® Gateway Installation Guide
6/13
2.2 Powering the Gateway
2.2.1 AC Powered Gateway
The i-ALERT® AC Gateway is by default shipped with a 110 VAC/2 0 VAC cord separately. This gives the
user the option to hardwire the Gateway or to use the provided 110 VAC/2 0 VAC cord. When using the
standard plug-in cord, the rating is no longer classified as C1D2. Please consult standards pertaining to
the installation location when powering by this method. Once wired and powered into a 110 VAC/2 0
VAC outlet or hardwired it will discover and begin communicating with all i-ALERT2® sensors and posting
data to the ITT AI Platform®.
Figure 2: i-ALERT2® 120VA -24VA option
2.2.2 9-60 DC Powered Gateway
The gateway can be optionally ordered to be powered from 9-60VDC. When powered in this way, the
unit is wired as shown in Figure . Once powered the gateway will discover and begin communicating
with all i-ALERT2® sensors and posting data to the ITT AI Platform®.
Figure 3: i-ALERT2® Optional 9-60 VD Wiring

i-ALERT® Gateway Installation Guide
7/13
2.2.3 Conduit Fittings
The power cord gland may be replaced by a standard 20mm or ½” conduit fitting, See .
WARNING: If the i-ALERT2
®
Gateway is rewired using conduit, it must be installed by knowledgeable,
skilled personnel familiar with local and/or international electrical codes and regulations.
Figure 4: Replacement of gland with a conduit fitting

i-ALERT® Gateway Installation Guide
8/13
2.3 Mounting Options
The gateway is shipped with mounting ears and has an optional poll mounting bracket
2.3.1 Wall Mounting
The mounting ears are shown in 5. Each mounting ear is attached with two flat head screws (item#5).
Figure 6 provides information on the mounting hole pattern. The gateway should be mounted vertically
as shown in Figure 8.
Item
Description
Qty
1
IP68 Enclosure
1
2
IP68 Cover
1
3
Cover Screws
Mounting Ears
2
5
Mounting Ear Screws
7
Air Vent
1
8
Blank Plug
1
9
SIM Plug
1
10
Power Cable Gland
1
Figure 6: Gateway Back plate Mounting Diagram
Figure 5: Gateway Assembly

i-ALERT® Gateway Installation Guide
9/13
2.3.2 Pole Mounting
The i-ALERT® Gateway can be modified to be mounted with an optional pole mount bracket kit as shown
in Figure . The pole mount kit can be used with poles of diameter of 2 inches to 12 inches.
To mount the bracket to the gateway, remove the mounting ears by removing the screws ( X item #5,
Figure ). Then attach the brackets using the four screws (item #6) and washers (item #7) as shown in
Figure
Figure 7: Pole Mount Bracket Kit
.
Figure 8: Gateway with pole mount bracket
Tabla de contenidos
Otros manuales de Puerta de Machfu
Manuales populares de Puerta de otras marcas

LST
LST M500RFE-AS Manual de usuario

Kinnex
Kinnex Media Gateway Manual de usuario

2N Telekomunikace
2N Telekomunikace 2N StarGate Manual de usuario

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manual de usuario

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manual de usuario

Telsey
Telsey CPVA 500 - SIP Manual de usuario